Operation Features; Power Failure - Haier AB072FDAHA Instruction Manual

Mrv intelligent network indoor air-conditioner
Hide thumbs Also See for AB072FDAHA:
Table of Contents

Operation Features

Confirmation before running
Check whether earthing wire is broken or falls off.
Check whether air filter was omitted.
Switch on power supply of the outdoor unit 12 hours in priority to entrust.
Heat ability
During heating program, the machine adopts heat pump mode to release heat indoors with that absorbed from outdoors.
Therefore its heating ability reduces when outdoor temperature descends.
Removal of frost in heat operation
During heat operation, if the outdoor unit is adhered with frosts, the machine will automatically turn to frost-
removing operation which lasts about 2~10 minutes.
During frost-removing operation, fan of indoor unit runs at low speed or stops while outdoor unit stops.
3 minutes protection
To protect the machine, for immediate restart after a stop, the compressor does not run until after a interval of 3 minutes.

Power failure

All operations will stop when there is a power failure during the machineís running.
Running indicator on remote controller flashes when the system is reenergized after power failure.
Before restart, press on/off button of the remote controller.
Note: If you have set power down memory function, the machine will get back to the status before power failure when it is
reenergized.
Protection setting (High pressure switch)
If something abnormal happens with the machine, the protection setting will act to stop running automatically. Press
ì checkî button on the remote controller to see failure code shown.
Protection setting acts in the following case.
During cool operation
Inlet or outlet of outdoor unit is blocked.
Strong wind continuously blows into the outlet of outdoor unit.
During heat operation
Large amount of dust adheres on air filter screen of indoor unit.
Outlet of indoor unit is blocked.
Air filer of cassette type
Air filter screen must be installed near the inlet when installing air-conditioner of flush type. After trial run
of the machine, verify the following items:
Position where air filter screen is installed
Operation of fans of units that stop
To protect units that stop during running of other indoor unit, run their fans for 2~8
minutes at an interval of 30 or 60 minutes.
Note:
Confirm failure code shown on the remote controller, shut down power switch and find out reasons after
protection setting works. (check method as seen from " check" on page 21). Continuous operation without
solving problems can cause faults of the machine.
Ensure air filter is installed. Without the filter, dust may accumulate on heat exchanger and cause water
leakage.
Each indoor unit can run individually or many indoor unit run in meantime. However, heat and cool operation
cannot be run at the same time.
How to disassemble the filter
5
How to clean the filter
Table of Contents