4 Operation
Item
Indoor unit /
b1 Indoor unit:
domestic
hot water
tank
: Floor-standing indoor unit with integrated
tank
b2
b2 Water pressure
b1
Space
c ▪
: Cooling (only with EKHVCONV2 installed)
operation
: Heating
mode
Disinfection
d ▪
: Disinfection mode active
/ Powerful
: Powerful operation active
Date / time
e Current date and time
Holiday
f
: Holiday mode active
Main zone
g1 Heat emitter type:
g3
g4
: Underfloor heating
g2
g1
: Fancoil unit
: Radiator
g2 Leaving water temperature setpoint
g3 Room thermostat type:
: Daikin user interface used as room
thermostat
: External control
▪ Hidden: Leaving water temperature control
g4 Measured room temperature
Additional
h1 Heat emitter type:
zone
: Underfloor heating
h3
: Fancoil unit
h1 h2
: Radiator
h2 Leaving water temperature setpoint
h3 Room thermostat type:
: External control
▪ Hidden: Leaving water temperature control
Domestic
i1
: Domestic hot water
hot water
i2 Measured tank temperature
i1
i2
Malfunction
j
or
: A malfunction occurred
See
"7.1 To display the help text in case of a
malfunction" [ 4  15] for more information.
4.2.2

Main menu screen

Starting from the home screen, press (
left dial to open the main menu screen. From the main menu, you
can access the different setpoint screens and submenus.
2
Malfunctioning
Room
Main zone
Additional zone
Space heating/cooling
a
Selected submenu
Operation manual
6
Description
) or turn (
) the
a
Possible actions on this screen
Go through the list.
Enter the submenu.
Enable/disable breadcrumbs.
Submenu
[0]
Restriction: Only displayed if a
or
malfunction occurs.
Malfunctioning
See
case of a
information.
[1]
Restriction: Only displayed if a room
Room
thermostat is connected to the indoor
unit.
Set the room temperature.
[2]
Shows the applicable symbol for your
Main zone
main zone emitter type.
Set the leaving water temperature for
the main zone.
[3]
Additional zone Restriction: Only displayed if there
are two leaving water temperature
zones. Shows the applicable symbol
for your additional zone emitter type.
Set the leaving water temperature for
the additional zone (if present).
[4]
Shows the applicable symbol for your
Space heating/
unit.
cooling
Put the unit in heating mode or cooling
mode (only with EKHVCONV2
installed). You cannot change the
mode on heating only models.
[5]
Restriction: Only displayed if a
Tank
domestic hot water tank is present.
Set the domestic hot water tank
temperature.
[7]
Gives access to user settings such as
User settings
holiday mode and quiet mode.
[8]
Displays data and information about
Information
the indoor unit.
[9]
Restriction: Only for the installer.
Installer
settings
Gives access to advanced settings.
[A]
Restriction: Only for the installer.
Commissioning
Perform tests and maintenance.
[B]
Change the active user profile.
User profile
[C]
Turn heating/cooling functionality and
Operation
domestic hot water preparation on or
off.
4.2.3

Setpoint screen

The setpoint screen is displayed for screens describing system
components that need a setpoint value.
Examples
[1] Room temperature screen
1
+
21
°C
Room
Description
"7.1 To display the help text in
malfunction" [ 4  15] for more
[2] Main zone screen
2
+
35
°C
Main zone
EAVZ16S18+23DA6V(7)+9W
Daikin Altherma 3 H F
4P556074-1A – 2021.09
Table of Contents
loading

Table of Contents