Daikin EBLQ-C2V3 Installer's Reference Manual
Daikin EBLQ-C2V3 Installer's Reference Manual

Daikin EBLQ-C2V3 Installer's Reference Manual

Altherma monobloc compact outdoor unit
Table of Contents

Quick Links

Installer reference guide
Daikin Altherma monobloc compact outdoor unit
Installer reference guide
EBLQ05C2V3
English
Daikin Altherma monobloc compact outdoor unit
EBLQ07C2V3
Table of Contents
loading

Summary of Contents for Daikin EBLQ-C2V3

  • Page 1 Installer reference guide Daikin Altherma monobloc compact outdoor unit Installer reference guide EBLQ05C2V3 English Daikin Altherma monobloc compact outdoor unit EBLQ07C2V3...
  • Page 2: Table Of Contents

    About connecting the water piping......15 6.4.2 Precautions when connecting the water piping... 15 6.4.3 To connect the water piping........15 6.4.4 To insulate the water piping ........16 Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 3: For The Installer

    ▪ In potentially explosive atmospheres. comply with applicable legislation (on top of the ▪ In places where there is machinery that emits electromagnetic instructions described in the Daikin documentation). waves. Electromagnetic waves may disturb the control system, and cause malfunction of the equipment.
  • Page 4: Brine

    ▪ Charge the liquid refrigerant as follows: Then A siphon tube is present Charge with the cylinder upright. (i.e., the cylinder is marked with "Liquid filling siphon attached") Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 5: Electrical

    ▪ Format: Digital files on http://www.daikineurope.com/support- and-manuals/product-information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer. The original documentation is written in English. All other languages are translations. EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 –...
  • Page 6: Installer Reference Guide At A Glance

    ▪ Bring the packed unit as close as possible to its final installation position to prevent damage during transport. ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). ▪ Prepare the path along which you want to bring the unit inside in advance.
  • Page 7: About The Units And Options

    10 m. Power supply NOTICE ▪ Do NOT stack the units on each other. ▪ Do NOT hang the unit on a ceiling. EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 8: Additional Installation Site Requirements Of The Outdoor Unit In Cold Climates

    NOT affect the unit. If lateral snowfall is possible, make sure that the heat exchanger coil is NOT affected by the snow. If necessary, install a snow cover or shed and a pedestal. Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 9: Preparing Water Piping

    ▪ Water temperature. All installed piping and piping accessories (valve, connections,…) MUST withstand following ▪ You might need to adjust the pre-pressure of the expansion temperatures: vessel. EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 10: Changing The Pre-Pressure Of The Expansion Vessel

    7 m. ▪ Check if the water 5.3.5 To check the water volume: Examples volume does exceed the maximum Example 1 allowed water volume. Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 11: Preparing Electrical Wiring

    E.g. time-of-use rates, seasonal rates, Wärmepumpentarif in Germany and Austria, ... EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 12: Overview Of Electrical Connections For External And Internal Actuators

    "5 Preparation" [ 4  7]. Opening the units 6.2.1 About opening the units At certain times, you have to open the unit. Example: ▪ When connecting the electrical wiring Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 13: Precautions When Mounting The Outdoor Unit

    In any case, provide at least 300  mm of free space below the unit. Additionally, make sure the unit is positioned at least 100 mm above the maximum expected level of snow. (mm) Maximum snowfall height EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 14: To Install The Outdoor Unit

    150  mm of the bottom side of the unit in order to prevent water from getting into the unit and to avoid drain water dripping (see the following figure). Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 15: To Prevent The Outdoor Unit From Falling Over

    NOTICE To protect the water circuit against freezing, add glycol. For instructions, see the installation manual of the domestic hot water tank. EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 16: To Insulate The Water Piping

    Excessive strip length may cause electrical shock or DANGER: RISK OF ELECTROCUTION leakage. 3 Insert the wiring at the back of the unit: WARNING ALWAYS use multicore cable for power supply cables. Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 17: To Connect The Main Power Supply

    CAUTION Do NOT push or place redundant cable length in the unit. Interconnection cable (=main power supply) Normal kWh rate power supply EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 18: To Connect The Remote Outdoor Sensor

    Next commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin Business Portal (authentication required). The general commissioning checklist is complementary to the instructions in this chapter and can be used as a 6.5.7...
  • Page 19: Checklist Before Commissioning

    Once the test run is finished and the unit operates properly, please make sure the following is clear for the user: of the outdoor unit Check the following at least once a year: EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 20: 10 Troubleshooting

    1 Remove the valve cap from the liquid stop valve and the gas stop valve. Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 21: To Start And Stop Forced Cooling

    5°C (see temperature read out of the indoor unit). You can achieve this, for example, by activating all fans of the fan coil units. EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 22: 12 Technical Data

    12 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin Business Portal (authentication required). 12.1 Piping diagram: Outdoor unit...
  • Page 23: Wiring Diagram: Outdoor Unit

    X1M, X2M Terminal strip PCB3 Service PCB Electronic expansion valve coil # Shut-off valve Reversing solenoid valve coil XAG1 Terminal strip Z1C~Z4C Ferrite core Optional Field supply EBLQ05+07C2V3 Installer reference guide Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 24: Esp Curve: Outdoor Unit

    ▪ Selecting a flow outside the operating area can damage the unit or cause the unit to malfunction. B (l/min) 4D097263 EDLQ07CAV3+EBLQ07CAV3 A (kPa) B (l/min) 4D097263 External static pressure Water flow rate Operation range Notes: Installer reference guide EBLQ05+07C2V3 Daikin Altherma monobloc compact outdoor unit 4P598847-1 – 2019.10...
  • Page 25: 13 Glossary

    Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with product according instructions accompanying documentation.
  • Page 28 4P598847-1 2019.10...

This manual is also suitable for:

Eblq05c2v3Eblq07c2v3

Table of Contents