Installer Settings: Tables To Be Filled In By Installer; Quick Wizard; Space Heating/Cooling Control; Domestic Hot Water Control [A.4] - Daikin Altherma EBLQ05CAV3 User Reference Manual

Low temperature monobloc
Hide thumbs Also See for Altherma EBLQ05CAV3:
Table of Contents
4.10
Installer settings: Tables to be
filled in by installer
4.10.1

Quick wizard

Setting
Space heating/cooling settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Glycol present
Outdoor unit [A.2.2]
DHW pump
External sensor (outdoor)
Control box [A.2.2.E]
Backup heater steps
BUH type
Preferential kWh rate
DHW operation
Contact type main
Contact type add.
Option box [A.2.2.F]
Ext. backup heat src
Alarm output
External kWh meter 1
External kWh meter 2
External sensor (indoor)
PCC by digital inputs
Capacities [A.2.3]
Booster heater
BUH: step 1
BUH: step 2
4.10.2

Space heating/cooling control

Setting
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Leaving water temperature: Delta T source [A.3.1.3]
Heating
Cooling
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
4.10.3

Domestic hot water control [A.4]

Setting
Type
Maximum setpoint
EBLQ05+07CAV3 + EDLQ05+07CAV3
Daikin Altherma low temperature monobloc
4P405545-1C – 2018.06
Default
Fill in...
2 (RT)
1 (Room)
1 (1 LWT zone)
2 (Request)
0 (No)
0 (No)
0 (No)
0
1 (1P,(1/1+2))
0 (No)
0 (No)
1 (Thermo)
1 (Thermo)
0 (No)
0 (NO)
0 (No)
0 (No)
0 (No)
0 (No)
3 kW
Depends on
model
Depends on
model
Default
Fill in...
1 (WD)
1 (WD)
5°C
5°C
1 (Yes)
0 (Quick)
Default
Fill in...
1 (R+S)
60°C

5 Setting the energy prices

INFORMATION
There is a risk of space heating (cooling) capacity
shortage/comfort problem (in case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruption will happen) when selecting [6‑0D]=0 ([A.4.1]
Domestic hot water Type=Reheat only) in case of a
domestic hot water tank without an internal booster heater.
INFORMATION
When the DHW tank booster mode is active, the risk of
space heating/cooling and capacity shortage comfort
problems is significant. In case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruptions will happen.
4.10.4

Contact/helpdesk number [6.3.2]

Setting
Contact/helpdesk number
5
Setting the energy prices
If your system's savings mode is set to Economical, it allows you to
set:
▪ a fixed fuel price
▪ 3 electricity price levels
▪ a weekly schedule timer for electricity prices.
The savings mode is set by the installer and can be either ecological
or economical. In ecological mode, the primary energy use is
minimised; in economical mode, the running costs. Discuss with the
installer which savings mode is preferred. Refer to the installation
manual for more information.
Example: How to set the energy prices on the user interface?
Price
Fuel: 5.3 euro cent/kWh
Fuel: 4.8 pence/kWh
Electricity: 12 euro cent/kWh
Electricity: 12.49 pence/kWh
5.1

To set the fuel price

1 Go to [7.4.6]:
> User settings > Preset values > Fuel price.
2 Use
and
to set the correct price.
3 Press
to confirm.
INFORMATION
▪ Price value ranging from 0.00~290 valuta/MBtu (with 2
significant values).
▪ Price value ranging from 0.00~990  valuta/kWh (with 2
significant values).
5.2

To set the electricity price

1 Go to [7.4.5]:
> User settings > Preset values > Elec price.
2 Use
and
to set the correct prices for High, Medium and
Low, according to your electricity tariff.
3 Press
to confirm.
INFORMATION
Price value ranging from 0.00~990  valuta/kWh (with 2
significant values).
Default
Fill in...
Value in breadcrumb
[7.4.6]=5.3
[7.4.6]=4.8
[7.4.5.1]=12
[7.4.5.1]=12
User reference guide
21