AEQ AM-04 User Manual

Analog, aes/ebu and sdi embedded audio self-powered monitor with alarm system

Quick Links

AEQ
AM-04
Analog, AES/EBU and SDI embedded Audio Self-powered
Monitor with Alarm system
USER'S MANUAL
ED. 05/09
V. 1.0 - 19/05/2009
A.E.Q., S.A., the company that manufactures this equipment, is an AENOR "registered
company" under number ER-080/1/96, in compliance with ISO - EN - 9001 standard.
Table of Contents
loading

Summary of Contents for AEQ AM-04

  • Page 1 AM-04 Analog, AES/EBU and SDI embedded Audio Self-powered Monitor with Alarm system USER’S MANUAL ED. 05/09 V. 1.0 - 19/05/2009 A.E.Q., S.A., the company that manufactures this equipment, is an AENOR “registered company” under number ER-080/1/96, in compliance with ISO - EN - 9001 standard.
  • Page 2 5.4. ADJUSTING BARGRAPHS BREAK-POINTS AND BALLISTINCS 5.5. INSERTING BARGRAPHS GRATICULES 6. REMOTE CONTROL PROTOCOL 6.1. DATA FORMAT 7. PROBLEMS SOLVING 7.1. SAMPLE PROBLEMS AND THEIR SOLUTIONS 8. SPECIFICATIONS AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 3 1.1.2. Power supply and earth connections. To reduce the risk of electric shock, the power supply of this AM-04 unit should be connected to earth. The equipment is supplied with an earth connection socket. 1.1.3. Protection from excessive supply voltage variation...
  • Page 4 AEQ shall not be liable for loss of information in the disks or data support that have been altered or found to be inexact, neither for any accidental damage caused by the user or other persons manipulating the product.
  • Page 5 INTRODUCTION The AEQ AM-04 is a professional audio monitor and alarm system housed in a 1U rack. The unit features three internal speakers, left, right and bass. Audio input signals can be in the form of analog, AES and SDI embedded data.
  • Page 6: Block Diagram

    Alarm tone is added just before the speaker output. When select switches are used a soft mute is applied to the audio to reduce glitches. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 7: Operation

    Note: To prevent de-muxed audio from being corrupted or muted, ensure that the 525/625 switch at the rear of the unit is correct for the SDI source. 3.2. USING ALARMS The AM-04 can provide the following warnings: Alarm event Notes...
  • Page 8 Note: Restoring input signals to normal condition does not clear alarms. Arming phase alarms Only the phase LED on the AM-04 front panel is armed using the SET switch. The audio tone and external phase alarms can only be armed using serial control.
  • Page 9 AM – 04 scale graticules Note: Bargraph color transition points and peak hold decay may also be adjusted internally. Refer to the Configuration chapter for switch settings and graticule fitting instructions. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 10: Installation

    INSTALLATION The AM-04 1U frame may be installed in 19 inch bays with 327mm depth including typical cable and connector depth. The dimensions of the AM-04 are 483x283x44.3. Its weight is 5kg and the max power dissipated is 60 W.
  • Page 11: Alarms Connector

    AM-04 has one 15 pin D type connector with the followings AES and analog outputs. Description Ch 1+ Ch 1- Ch 3+ Ch 3- AES3 1_2 AES3 3_4 Ch 2+ Ch 2- Ch 4+ Ch 4- Chassis Note: The analogue output is balanced and the AES output is unbalanced.
  • Page 12: Data Connector

    Rx (from host) Tx (to host) Not connected Not connected Not connected Not connected Not connected Note: A null-modem lead will be required to interface to a PC. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 13 CONFIGURATION Access to AM-04 internal adjustments is obtained with the top removed. AM – 04 internal adjustments The following adjustments may be made: Monitor output level. SW3 & potentiometers main board RV1 & RV2 • Analog output level. SW1 & SW2 & potentiometers output sub-board •...
  • Page 14: Adjusting Analog Input Level

    Note: It is intended that only one switch lever is set ON for each analog input. The ON position is obtained with a switch lever in the direction of the arrow (downward in the above drawing). *Clockwise rotation increases gain. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 15 Note: It is intended that only one switch lever is set ON for each analog output. The ON position is obtained with a switch lever in the direction of the arrow (downward in the above drawing). *Clockwise rotation increases gain. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 16: Adjusting Audio Monitor Output Level

    Note: It is intended that only one switch lever is set to ON for each monitor output. The ON position is obtained with a switch lever in the direction of the arrow (downward in the above drawing). *Clockwise rotation increases gain. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 17 5.4. DJUSTING BARGRAPHS BREAK-POINTS AND BALLISTICS The adjustments, SW2 and SW6 are located near the power supply. AM-04 bargraph adjustments SW2-8 AES to analog adjust 18dBFS = 0 on analog scale -20dBFS = 0 on analog scale The .18dB and .20dB settings define the correspondence between AES input level and the 0 mark on an analog scale.
  • Page 18 Choosing how many segments are colored red from the top of the bargraph sets the .red zone. Select from none to 25 using SW2-2, SW2-1, SW6-8, SW6-7 and SW6-6 as follows: SW2-2 SW2-1 SW6-8 SW6-7 SW6-6 Segment from bargraph top None AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 19 Choosing how many segments are colored amber from the end of red zone, sets the amber zone. Select from none to 25 using SW6-5, SW6-4, SW6-3, SW6-2 and SW6-1 as follows: SW26-5 SW6-4 SW6-3 SW6-2 SW6-1 Segment from last RED ZONE None AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 20: Inserting Bargraph Graticules

    Note: Any remaining unassigned segments will be green 5.5. INSERTING BARGRAPH GRATICULES The following bargraph scale graticules are supplied with each AM-04 AM – 04 scale graticules To apply a graticule proceed as follows: 1. Peel back the protective backing from the chosen graticule 2.
  • Page 21 4. Ensure that the bargraph setting matches the graticule 5. Adjust the color transitions and peak hold decay as desired AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 22: Remote Control Protocol

    6. REMOTE CONTROL PROTOCOL The AM-04 is automatically placed in the remote mode upon receipt of a valid RS232 command. The front panel can be reactivated by powering off and on or by sending it a disconnect command. Commands to be communicated to the remote unit (AM-04) are arranged in frames. These frames will then be sent to the remote unit, which will always reply with either ACK for acceptance or NAK for rejection.
  • Page 23 Replies, when requested (e.g. 82), will consist of frames that contain the original command value plus 0X40. So a request for an ident, 0x82, will elicit a reply of a frame containing 0xC2 and the ident string. (AM - 04Vn.n) AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 24: Data Format

    6.1. DATA FORMAT General Prompt (0x80) This command will cause the AM-04 to respond with an ACK or NACK reply. It can be used to poll for alarms. Set up switches (0x83) Bit 7 Bit 6 Bit 5 Bit 4...
  • Page 25 7 Second hold time Indefinite hold time AES offset This bit selects the bar graph offset when AES is input to an analog bar graph. Code Function -18 dB -20 dB AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 26 Phase Byte 1 Disable The Auto bit will cause the AM-04 to generate spontaneous ACK signals every second while an alarm is active. The toggle disable bit will inhibit the set-up function of the front panel toggle switch. Request Detail (0x85) This command will cause the AM-04 to respond with a frame containing the command 0XC5 and data describing the state of the unit and any alarms.
  • Page 27 A character was detected before receipt of a start character A checksum error occurred. The erroneous value is placed in Byte 1). RS232 format 8 data bits, no parity, 2 stop bits, 9600 Baud. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 28: Problem Solving

    Mute the alarm with the ALARM MUTE switch or reset all alarms with the ALARM RESET switch by holding it upwards for more than 3 seconds. An input signal has failed but no alarm was asserted AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 29 Check the position of the PAL/NTSC switch at the rear of the unit. Note: In the unlikely event that the unit locks up, switch the unit off at the rear for a few seconds and then restore power. AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 30: Specifications

    4 x hi-resolution tri-color bargraphs Note: All audio measurements made using Audio Precision un-wtd 22Hz to 22kHz VIDEO Input: 1xSDI SMPTE 259M Output 1 x composite video converted from SDI input AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 31 Attack time: 300 ms Fallback: 300 ms. AES/EBU: Overall dynamic range: 60 dB (0 to -60 dB) Attack time: 1 ms Fallback: 1,5 s per 20 dB decay AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...
  • Page 32 60W (max) 90-264 VAC 50-60Hz Autoselect, Fuse 4A HAC Enviromental. Temperature 0° C to 30° C Humidity 70% max (non-condensing) Weight. 5 kg. (11.6lbs) Computer interface. 9 pin RS-232 male PC-AT serial interface (null-modem) AEQ AM-04 Analog, AES/EBU and SDI embedded Audio Monitor with Alarm System...

Table of Contents