Honeywell Q7055C1053 Installation Instructions Manual
Honeywell Q7055C1053 Installation Instructions Manual

Honeywell Q7055C1053 Installation Instructions Manual

Meter point connect

Quick Links

Q7055C Honeywell Meter Point
Connect
GENERAL
WARNING
This equipment generates, uses and can radiate
radio frequency energy, and if not installed and
used in accordance with the Instructions Manual,
may cause interference with radio communication.
It has been tested and found to comply with the
limits for a Class A computing device pursuant to
Subpart J of Part 15 or FCC Rules, which are
designed to provide reasonable protection against
such interference when operated in a commercial
environment. Operation of this equipment in a
residential area is likely to cause interference, in
which case, users at their own expense will be
required to take whatever measures may be
required
to
correct
unauthorized modification of this equipment may
result in the revocation of the owner's authority to
continue its operation.
GENERAL
The Q7055C series Honeywell Meter Point Connect (MPC)
provides connection to sub-metering devices via M-Bus level
converter using MeterBus Protocol. The Meter Point
communicates to EBI-Central over an industry standard 10/
100BaseT Ethernet LAN. It delivers exceptional price/
performance to meet the requirements of both building owners
and service providers. The Meter Point communicates to sub-
metering devices via a M-Bus level converter using M-Bus
standards: EN13757-3 and EN1434-3. With its combination of
scalable performance, density, and low per-port pricing, the
MPC allows network layer capabilities to be extended to a
much
wider
range
of
environments. Customers can now gain the advantages of
high-performance network and services, including traffic
management, to more locations throughout the network. The
the
interference.
Any
network
configurations
INSTALLATION INSTRUCTIONS
Q7055C MPC-Model M1 provides a single RS-485 DC
coupled
M-Bus-compatible
submetering devices.
M-Bus compatible sub-metering devices support baud-rates
from 300 bps to 19200 bps. The Q7055C MPC-Model M2
provides
two
RS-485
communication channels for submetering devices.
HONEYWELL METER POINT CONNECT TOPOLOGY
EBI SERVER
RS485-RS232
CONVERTER
M-BUS LEVEL
LC
CONVERTER
M-BUS SUPPORTED
SUB-METERING DEVICES
The MPC uses the LAN connection to provide a seamless
communication to the requesting device. Status information,
and
like
LAN
communication
communication and system heartbeat of the MPC is indicated
by LEDs on the device front.
communication
DC
coupled
M-Bus-compatible
EBI CLIENT
M-BUS ROUTER
ETHERNET
LOCAL AREA NETWORK
MPC M-BUS CH1, CH2
MPC M-BUS CH1
RS485
RS485
RS485-RS232
CONVERTER
RS232
RS232
RS485
RS232
RS232
M-BUS LEVEL
LC1
LC2
CONVERTER
M-BUS SUPPORTED
SUB-METERING DEVICES
Fig. 1. MPC network.
activity,
field
Put Bar Code Here
channel
for
M25412
bus
traffic
39−00002
Table of Contents
loading

Summary of Contents for Honeywell Q7055C1053

  • Page 1 RS485-RS232 RS485-RS232 CONVERTER CONVERTER RS232 RS232 RS485 RS232 The Q7055C series Honeywell Meter Point Connect (MPC) RS232 M-BUS LEVEL M-BUS LEVEL provides connection to sub-metering devices via M-Bus level CONVERTER CONVERTER converter using MeterBus Protocol. The Meter Point communicates to EBI-Central over an industry standard 10/ 100BaseT Ethernet LAN.
  • Page 2: Specifications

    Relay Model PW60: RS485 > M-Bus level converter for up to 60 devices. Models: Q7055C1053 Honeywell Meter Point Connect Model M1. ADFweb Model HD67022M-20: RS485 > M-Bus level Q7055C1055 Honeywell Meter Point Connect Model M2. converter for up to 20 devices.
  • Page 3: Before Installation

    NOTE: There are cooling slots on the top and bottom of Applicable Literature the MPC housing. — Form no. 39-00001, Q7055C1053 MPC-M1 (Single M- Bus) and Q7055C1055 MPC-M2 (Dual M-Bus) Speci- fication Data Sheet. — Form no. 39-00002, Q7055C1053 MPC-M1 (Single M- Bus) and Q7055C1055 MPC-M2 (Dual M-Bus) Instal- lation Literature.
  • Page 4: Wall Mounting

    Q7055C HONEYWELL METER POINT CONNECT CONNECTIONS Wall Mounting It is also possible to mount the MPC device to a wall using the This section describes how to connect power and the field bus optional 50008533-001/U Wall Hanging Accessories Kit. The to the MPC device.
  • Page 5: Ethernet Connection

    Q7055C HONEYWELL METER POINT CONNECT Ethernet Connection Consult form no. 39-00003, Q7055C Honeywell Meter Point Connect MPC-Model M1/Model M2 Checkout & Test for See Fig. 7 for MPC Ethernet connection. additional information on field bus wiring. CABLES AND CONNECTORS DB9F Null Modem Connector Fig.
  • Page 6: Operation

    39-00003, Q7055C Honeywell operation modes, refer to the Operating Modes section of form Meter Point Connect MPC-Model M1/Model M2 Checkout & no. 39-00003, Q7055C Honeywell Meter Point Connect MPC- Test. Model M1/Model M2 Configuration, Checkout & Test Guide.
  • Page 7: Maintenance Procedures

    AC/DC IN 10/100 The Q7055C MPC has no user replaceable fuses. For service, contact your local Honeywell Automation & Control Solutions M30015 office as listed in the phone book, or contact a regional office as shown at the end of this document.
  • Page 8 Q7055C HONEYWELL METER POINT CONNECT Automation and Control Solutions Honeywell GmbH Boeblinger Straße 17 71101 Schoenaich, Germany Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 ® U.S. Registered Trademark © 2016 Honeywell International Inc. www.honeywell.com/buildingsolutions 39-00002 A.A. Rev. 04-16...