A. TEST PROCEDURES
COMPONENTS
TRANSFORMER
MAGNETRON
TEST
FILAMENT
WINDING
PRIMARY
WINDING
1. Remove wire leads.
2. Measure resistance. (ohm meter scale: Rx1)
• Primary winding
High
Low
• Secondary winding
• Filament winding
3. Measure resistance. (ohm meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Remove wire leads. Install the magnetron seal in
the correct position. Check that the seal is in
good condition.
2. Measure resistance. (ohm meter scale: Rx1)
• Filament terminal
3. Measure resistance. (ohm meter scale: Rx1000)
• Filament to chassis
7-15
SECONDARY
WINDING
Antenna
Gasket
Chassis
Filament
RESULTS
Approx. 0.2 to 0.5 ohms
Approx. 0.2 to 0.5 ohms
Approx. 50 to 120 ohms
0 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite

Hide quick links: