Daikin ARM24MV2S Service Manual

Daikin ARM24MV2S Service Manual

6.0/7.1 kw class 24000/28000 btu/h class
REMOVAL
PROCEDURE
S E R V I C E
6.0/7.1 kW Class
24000/28000 Btu/h Class
Outdoor Unit
Non-Inverter
Pair Type
Si011359EA
M A N U A L
loading

Summary of Contents for Daikin ARM24MV2S

  • Page 1 Si011359EA REMOVAL PROCEDURE S E R V I C E M A N U A L 6.0/7.1 kW Class 24000/28000 Btu/h Class Outdoor Unit Non-Inverter Pair Type...
  • Page 2 Service Manual Removal Procedure Outdoor Unit Cooling Only ARM24MV2S RM24NV2S RM28NV2S RM60JV14 RM71JV14 RM60KV1V RN60JV1G...
  • Page 3: Table Of Contents

    Si011359EA Table of Contents 1. Outer Panels ...................2 2. Outdoor Fan / Fan Motor.................6 3. Electrical Component ASSY ..............8 4. Sound Blankets ..................11 5. Compressor ASSY ................12 Note: The illustrations may be slightly different depending on the model. Removal Procedure...
  • Page 4: Outer Panels

    Outer Panels Si011359EA 1. Outer Panels Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the 8 screws Top panel of the top panel. (R5423) (R5424) Pull the suction grille to unfasten the 3 hooks.
  • Page 5 Si011359EA Outer Panels Step Procedure Points Unfasten the 3 hooks with a flat screwdriver Hook and remove the suction grille. (R5427) Remove the screw and remove the front panel (2). Front panel (R12807) When reassembling, fit the 5 hooks. (R12808) Remove the screw and When reassembling, fit the 3 remove the piping cover...
  • Page 6 Outer Panels Si011359EA Step Procedure Points Remove the 6 screws and remove the front panel (1). Front panel (1) (R12810) (R17188) (R8322) Removal Procedure...
  • Page 7 Si011359EA Outer Panels Step Procedure Points Remove the 9 screws and remove the right side panel. Right side panel (R15402) (R19346) When reassembling, fit the 2 hooks. Hook (R5442) Removal Procedure...
  • Page 8: Outdoor Fan / Fan Motor

    Outdoor Fan / Fan Motor Si011359EA 2. Outdoor Fan / Fan Motor Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Disconnect the relay connector for the fan motor.
  • Page 9 Si011359EA Outdoor Fan / Fan Motor Step Procedure Points Remove the nut and Nut size: M8 remove the outdoor fan. 13 mm (0.51 inch) (R19286) When reassembling, align mark of the outdoor fan with the D-cut section of the motor shaft. (R19285) D-cut (R12834)
  • Page 10: Electrical Component Assy

    Electrical Component ASSY Si011359EA 3. Electrical Component ASSY Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Detach the outdoor temperature sensor. Outdoor temperature sensor (R17451) Remove the sensor fixing plate.
  • Page 11 Si011359EA Electrical Component ASSY Step Procedure Points Remove the left screw If it is difficult to remove the and slide the outdoor outdoor temperature temperature thermostat thermostat, loosen the right to the left to remove it. screw. (R19288) Disconnect the X1M: terminal board to compressor to compressor...
  • Page 12 Electrical Component ASSY Si011359EA Step Procedure Points Lift the electrical Electrical component ASSY to component ASSY unfasten the 2 hooks and remove it. (R20876) When reassembling, Magnetic contactor (K1M) connect the wirings to the to X1M (1): red (fuse) correct position. to X1M (1): red to V1R (3): black to V1R (4): black...
  • Page 13: Sound Blankets

    Si011359EA Sound Blankets 4. Sound Blankets Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points Remove the sound Since the piping ports on the Sound blanket (top) blanket (top).
  • Page 14: Compressor Assy

    Compressor ASSY Si011359EA 5. Compressor ASSY Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Be careful not to get yourself burnt with the pipes and other parts that are heated by the gas brazing machine.
  • Page 15 Si011359EA Compressor ASSY Step Procedure Points Disconnect the Be careful so as not to burn compressor lead wires. the compressor terminals or Red (R) the name plate. Pattern 1 Blue (C) Yellow (S) (R5457) (R20873) Remove the gasket. Pattern 2 (R20874) S: yellow Gasket...
  • Page 16 Compressor ASSY Si011359EA Step Procedure Points Heat up the brazed part of the discharge side pipe and disconnect it. Brazed part of the discharge side pipe (R20880) Heat up the brazed part of the suction side pipe Brazed part of and disconnect it.
  • Page 17 Revision History Month / Year Version Revised contents 08 / 2013 Si011359E First edition 09 / 2014 Si011359EA Model addition: ARM24MV2S, RM24/28NV2S, RM60/71JV14, RM60KV1V...
  • Page 18 Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.