• Safety Instructions
• Installation
• Operation
• Troubleshooting
• Repair Parts
®
®
F642-05002
Form No.
(3/11/05)
Table of Contents
loading

Summary of Contents for Craftsman HYDROGLASS 390.2511

  • Page 1 OWNER’S MANUAL MODEL NO. 390.2511 ® “HYDROGLASS” ® CAUTION: Read and Follow CONVERTIBLE DEEP All Safety Rules and WELL JET PUMP Operating Instructions Before First Use of • Safety Instructions This Product. • Installation Save This Manual For • Operation Future Reference.
  • Page 2: Safety

    READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the fol- lowing signal words and be alert to the potential for per- sonal injury: DANGER warns about hazards that will cause serious per- sonal injury, death or major property damage if ignored.
  • Page 3: Table Of Contents

    CONTENTS INTRODUCTION Safety..................2 We suggest you take a few minutes to read the instructions contained in this manual before installing and using your Warranty/Introduction ............3 pump. This will help you obtain the full benefits of the qual- Installation...............4-8 ity and convenience built into this equipment. It will also help you avoid any needless service expense resulting from Electrical................9-10 causes beyond our control which naturally cannot be cov-...
  • Page 4 INSTALLATION – DEEP WELL PLASTIC PIPE 1" PLASTIC PIPE 1-1/4" WELL SEAL PIPE ADAPTERS 1" PLASTIC PIPE 1-1/4" PLASTIC PIPE CHECK VALVE AND STRAINER 1400 1194 Figure 1 – Captive Air ® Pressure Tank Installation - Deep Well PLASTIC PIPE 1"...
  • Page 5 INSTALLATION – SHALLOW WELL Figure 3 – Captive Air ® Pressure Tank Installation - Shallow Well Figure 4 – Standard Pressure Tank Installation - Shallow Well...
  • Page 6: Installation

    INSTALLATION NOTICE: Use Teflon tape supplied with the pump or Plasto- In a shallow well installation, the jet assembly is attached Joint Stik1 for making all pipe-thread connections to the directly to the pump because the vacuum created will pull pump itself.
  • Page 7 INSTALLATION STEEL PIPING INSTALLATIONS SHALLOW WELL INSTALLATION AND OPERATION When steel pipe is used to install the jet, be sure all pipes are clean and the ends are reamed. Screw both 1-1/4” NPT Installing the Pump on a Shallow Well suction pipe and 1"...
  • Page 8 INSTALLATION Discharge Pipe Sizes NEVER run pump dry. Running pump with- When the pump is set a distance from the house, barns, or out water may overheat unit, damaging seals and possibly other points of water use, the discharge pipe size should be burning persons handling pump.
  • Page 9: Electrical

    ELECTRICAL Disconnect power before working on pump, motor, pressure switch, or wiring. Motor Switch Settings Dial Type Voltage Selector If the motor can operate at either 115 or 230 volts, it is set Power Supply Connections at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor.
  • Page 10 ELECTRICAL Wiring Connections Connection Procedure Fire hazard. Incorrect voltage can cause 1. Connect the ground wire first as shown in Figure 10. a fire or seriously damage the motor and voids the war- The ground wire must be a solid copper wire at least ranty.
  • Page 11: Operation

    OPERATION MAINTENANCE PRIMING THE SHALLOW WELL PUMP LUBRICATION TO PREVENT DAMAGE TO INTERNAL PARTS, DO NOT It is not necessary to lubricate the pump or its motor. The START MOTOR UNTIL PUMP HAS BEEN FILLED WITH motor has two ball bearings lubricated for life. The me- WATER.
  • Page 12: Service

    SERVICE REMOVING MOTOR FOR SERVICE 8. Slide seal assembly on shaft (sealing face first) until rub- ber drive ring hits shaft shoulder. BE SURE you don’t chip AND REPLACING SHAFT SEAL or scratch sealing face on shaft shoulder. Should repair or replacement of motor or seal be necessary, 9.
  • Page 13 SERVICE CLEANING IMPELLER HOW TO HANDLE A GASEOUS WELL 1. Disassemble pump per disassembly instruction on Page 11. In some localities well water contains gases which must be allowed to escape before the water is used. This can be done 2.
  • Page 14: Troubleshooting

    TROUBLESHOOTING CHART SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Motor will not run 1. Disconnect switch is off 1. Be sure switch is on 2. Fuse is blown 2. Replace fuse 3. Starting switch is defective 3. Replace starting switch 4. Wires at motor are loose, 4.
  • Page 15: Pump Performance

    TROUBLESHOOTING CHART SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Leaks at the metal 1. Loose clamps or O-Ring 1. First check the clamp tightening screw to see if it is tight. If it is tight and clamps not sealed slight leakage still occurs, place a piece of wood on the clamp and firmly tap the wood with a hammer.
  • Page 16: Repair Parts

    REPAIR PARTS 1402 1194 1/2 HP Model Part 390.2511 Description J218-953C Motor - 1/2 HP, 115/230V, 60 Cycle 17351-0009 Water Slinger U78-107PT Reducer Bushing - 1/2" x 1/8" NPT 2768 Pressure Gauge L176-47P Pump Body (Back Half) U9-399 O-Ring - Pump Body - 9-1/2" x 9" x 1/4" U109-6A Shaft Seal J105-40PE...
  • Page 17 SHALLOW WELL JET AND CHECK VALVE ASSEMBLY STOCK NO. 29650 For Pump Model 390.2511 To Order Parts, Call Sears Product Service, 1-800-366-7278 Repair Parts Part Number Part Description U9-202 O-Ring - Jet Body J19-6 Clamp U9-201 O-Ring - Venturi N32P-72 Venturi J34P-41 #51 Nozzle...
  • Page 18 REPAIR PARTS Single Pipe Jets Double Pipe Jets SINGLE PIPE JETS Part Description Pkg. Max. Stamped Pump Stock Pumping Packer Check Valve Turned Casing Size Model Depth Venturi Nozzle* Nozzle Body Leather Spacer Washer Valve Seat Coupling Adapter 40’ J32P-24 J34P-44 J40-24 J57-1 J43-14P...
  • Page 19 REPAIR PARTS VERTICAL CASING ADAPTERS To Order Parts, Call Sears Product Service, 1-800-366-7278 1723 0495 2" AND 3" VERTICAL CASING ADAPTER 2" Vertical 3" Vertical Casing Casing Part Adapter Adapter Description – J216-13 – 2" Vertical Casing Adapter – – J216-14 3"...
  • Page 20 Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.