Symptom: The System Is Making Gurgling Noises After Commissioning; Disposal; Glossary - Daikin Altherma 3 R F EHFH03S18DJ3V Operation Manual

Hide thumbs Also See for Altherma 3 R F EHFH03S18DJ3V:
Table of Contents
6.5
Symptom: The system is making
gurgling noises after
commissioning
Possible cause
There is air in the system.
Various malfunctions.
(a)
We recommend to purge air with the air purge function
of the unit (to be performed by the installer). If you purge
air from the heat emitters or collectors, mind the
following:
WARNING
Air purging heat emitters or collectors. Before you
purge air from heat emitters or collectors, check if an error
or
is displayed on the home pages of the user interface.
▪ If not, you can purge air immediately.
▪ If yes, make sure that the room where you want to
purge air is sufficiently ventilated. Reason: Refrigerant
might leak into the water circuit, and subsequently into
the room when you purge air from the heat emitters or
collectors.
7

Disposal

NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
8

Glossary

DHW = Domestic hot water
Hot water used, in any type of building, for domestic
purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the heat pump.
EHFH03S18DJ3V
Daikin Altherma 3 R F
4P596804-1 – 2019.10
Corrective action
(a)
Purge air from the system.
Check if
is displayed on the
home pages of the user
interface. You can press
to
display more information about
the malfunction.
7 Disposal
Operation manual
11