This installation guide provides instructions for installation,
startup and adjustment. To receive a copy of the instruction
manual, contact your local Sales Office or view a copy
at www.fisher.com. For further information refer to:
CSB600 Series Commercial / Industrial Pressure Reducing
Regulators Instruction Manual, D103130X012.
PED Categories
This product may be used as a pressure accessory with
pressure equipment in the following Pressure Equipment
Directive. For information on the current PED revision see
Bulletin: D103053X012. Pressure regulator does not require
any supplementary upstream safety accessory for protection
against overpressure compared with its design pressure
PS, when upstream reducing station is sized for a max
downstream incidental MIPd <= 1.1 PS.
tyPE
DEsCrIPtIon
CSB600, CSB600F,
CSB620, CSB620F
Base regulator
and CSB650
CSB604, CSB604F,
Regulator with
CSB624, CSB624F
slam shut
and CSB654
European En reference standards
specifications
available Configurations
See Table 1
regulator type
Differential Strength (DS)
accuracy Class
Up to AC5 (depending on Outlet Pressure)
lockup Class
Up to SG10 (depending on Outlet Pressure)
Failure Mode per En334
Fail Open (FO)
Integral strength (Is) Pressure rating
See Table 2
Differential strength (Ds) Pressure ratings
See Table 3
Body sizes, Materials, End Connections and
Pressure ratings
(1)
See Table 4
operating Pressure range
regulator: See Table 5
slam-shut Module: See Tables 7a, 7b, 7c and 7d
1. The pressure/temperature limits in this Installation Guide or any applicable standard limitation should not be exceeded.
2. Standard token relief set values listed in Tables 7a, 7b, 7c and 7d are based on -20 to 60°C / -4 to 140°F.
3. Product has passed Emerson Process Management Regulator Technologies, Inc. (Emerson) testing for lockup, relief start-to-discharge and reseal down to -40°.
PED CatEgory
FluID grouP
Groups 1 and
I
2 according to
PED 2014/68/EU
1st and 2nd family
IV
gas according to
EN 437 or other
gases (compressed
air, Nitrogen). The
gas must be non-
EN 334 and
corrosive, clean
EN 14382
(filtration on inlet side
necessary) and dry.
(1)
(1)
(1)
Maximum outlet Pressure
Emergency Casing:
Type CSB600/CSB600F/CSB620/CSB620F:
4.0 bar / 58.0 psig
Type CSB650: 5.0 bar / 72.5 psig
to avoid Internal Metallic Parts Damage:
Type CSB600/CSB600F/CSB620/CSB620F:
0.34 bar / 5.0 psig over set pressure
Type CSB650: 1.5 bar / 21.8 psig – not to exceed
maximum emergency outlet
operating Casing:
Types CSB600 and CSB620: 1.1 bar / 16.2 psig
Type CSB650: 5.0 bar / 72.5 psig
outlet Pressure ranges
9.0 mbar to 4.0 bar / 0.13 to 58.0 psig
See Table 5
orifice size
25 mm / 1.0 in.
Pressure registration
External
temperature Capabilities
according to PED standards:
-20 to 66°C / -4 to 151°F
non-PED:
-30 to 66°C / -22 to 151°F
spring Case Vent Connection
1 nPt: Types CSB600 and CSB620
1/2 nPt: Type CSB650
type VsX8 slam-shut Device Maximum Inlet
Pressure (P
)
:
(1)
umax
Differential strength (Ds): 16 bar / 232 psig
Integral strength (Is): 6.0 bar / 87 psig
approximate Weights
with threaded body
Type CSB600/CSB620: 13 kg / 29 lbs
Type CSB650: 14 kg / 31 lbs
Type CSB604/CSB624: 14 kg / 31 lbs
Type CSB654: 15 kg / 33 lbs
with Flanged body
Add 5.2 kg / 11 lbs to weights listed
Designed, tested and Evaluated Consistent With:
ANSI B16, ASME BPVC Sec. VIII Div. I, ASTM B117
(Corrosion Resistance), EN 334 and EN 14382
Directive atEX Information
See Table 6
For information about ATEX, refer to CSB600 Series
(D103130X012) and VSX8 Series
(D103127X012) Instruction Manuals.
CSB600 Series
(1)
(1)
(1)(2)(3)
Table of Contents
loading

Summary of Contents for Emerson CSB600 Series

  • Page 1 2. Standard token relief set values listed in Tables 7a, 7b, 7c and 7d are based on -20 to 60°C / -4 to 140°F. 3. Product has passed Emerson Process Management Regulator Technologies, Inc. (Emerson) testing for lockup, relief start-to-discharge and reseal down to -40°.
  • Page 2 None Token Internal Relief Example: Type number CsB624Et: CSB600 Series regulator constructed for medium pressure applications, with Type VSX8 slam-shut module, with External pressure registration and with Token relief. 1. Reference Instruction Manual D103127X012 for information regarding the Type VSX8 Slam-Shut Module.
  • Page 3 1-1/4, 1-1/2 and 2 6.10 20.0 WCC Steel CL150 RF 20.0 10.0 PN 10/16 16.0 Table 5. CSB600 Series Primary Regulator Outlet Pressure Ranges sPrIng WIrE sPrIng FrEE oPEratIng PrEssurE rangE, W DIaMEtEr lEngth tyPE Part nuMBEr sPrIng Color mbar...
  • Page 4 CSB600 Series Table 7a. North American Overpressure Shut-off OPSO Only Ranges rEgulator slaM shut DEVICE type Factory set typical spring token relief range shown as a % required Difference Between over Pressure shut-off (Maximum setpoint range relief set of regulator setpoint...
  • Page 5 CSB600 Series Table 7c. North American Overpressure and Underpressure Shut-off UPSO/OPSO Ranges rEgulator slaM shut DEVICE required uPso oPso Factory set Difference type relief range shown typical token relief Between spring range as a % of regulator shut-off (oPso) adjusted...
  • Page 6: Installation

    Failure to take the regulator out of service immediately may create a CSB600 Series regulators with an “ET” or “EN” in the type hazardous condition. number use external pressure registration. To communicate Personal injury, equipment damage, or...
  • Page 7: Overpressure Protection

    Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external The CSB600 Series regulators have a 1 NPT screened vent sources or debris in the line. The regulator should be opening in the spring case. If necessary to vent escaping inspected for damage after any overpressure condition.
  • Page 8: Parts List

    CSB600 Series Parts list Description Description Spring Case, Aluminum Pin, Stainless steel Stabilizer Guide, Stainless steel Roller Pin, Brass Stabilizer, Lustran Diaphragm Assembly ® Spring, Stainless steel Closing Cap, Aluminum Retaining Ring, Zinc-plated carbon steel Bonnet, Zinc-plated steel Stabilizer Screw, Zinc-plated steel (3 required)
  • Page 9: Relief Valve

    ProtECt VEnt PIPE WIth raIn CaP CsB600 sErIEs rEgulator Dn 50 / nPs 2 tyPE 289h rElIEF ValVE Figure 3. CSB600 Series Regulator Installed with the Vent Pointed Downward and with a Type 289H Relief Valve for High Capacity Relief...
  • Page 10 CSB600 Series TORQUE: 6 TO 8 N•m / 111F 4 TO 6 FT-LBS 111G TORQUE: 14 TO 18 N•m / 111A 10 TO 13 FT-LBS DETAIL M INITIAL TORQUE: DAMPER FOR TYPE CSB600F 7 TO 9 N•m / 5 TO 7 FT-LBS MINIMUM RELAXATION TORQUE: 5 N•m / 4 FT-LBS...
  • Page 11 CSB600 Series TORQUE: 6 TO 8 N•m / 4 TO 6 FT-LBS TORQUE: 12 N•m / TORQUE: 9 FT-LBS MAXIMUM 14 TO 18 N•m / 10 TO 13 FT-LBS INITIAL TORQUE: 7 TO 9 N•m / 5 TO 7 FT-LBS MINIMUM RELAXATION TORQUE: 5 N•m / 4 FT-LBS...