Creep Speed; Controlled Acceleration And 1A Time; Setup Functions For Traction Controller - GE IC3645SR4U454Z2 Installation And Operation Manual

Separately excited (sx) transistorized dual motor controllers and series pump motor control
Table of Contents
ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
LX
HANDSET
g
EVC
CONT
CONT
CONT
CONT
STORE
STORE
STORE
STORE
1
2
3
+
5
6
7
9
10
11
13
14
15
Section 6.4 Setup Functions for Traction Controller
FUNCTION 1
MPH SCALING ( When Used )
( Push 1 )
This function allows for the pulses from the tachometer to
be scaled to miles per hour, based on the number of pulses
received by the control in a given time. For example, if you
were scaling to 8 MPH, it would correspond to the length of
time that it took to capture 8 tachometer pulses when the
vehicle is traveling at 8 MPH.
Range
Set
Resolution
Example:
FUNCTION 2

CREEP SPEED

( Push 2 )
This function allows for the adjustment of the creep speed
of the vehicle. Creep speed can be adjusted when an
accelerator input voltage between 3.9 and 3.3 volts or an
accelerator ohm input between 6.0 K and 4.0K ohms is
provided.
Range
Set
4
+
8
12
ESC
ESC
ESC
ESC
0 to 1.28 seconds
0 to 255
0.005 seconds per set unit
Setting of 20 = 0.1 seconds
2% to 15% on time
0 to 255
Resolution
Example:
Important Note: The function is used to optimize motor and
control performance and this setting will be determined by
GE and OEM engineers at the time of vehicle development.
This setting must not be changed by field personnel without
the permission of the OEM.
FUNCTION 3
ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push 3)
This function allows for the adjustment of the rate of time it
takes for the control to accelerate to 100% applied battery
voltage to the motor on hard acceleration.
Range
Set
Resolution
Example:
FUNCTION 4
ARMATURE CURRENT LIMIT
(Push 4)
This function allows for the adjustment of the armature
current limit of the control. The rating of the control will
determine the range of adjustment for this function. Please
refer to the operating instructions and current limit curves
for the control used in specific vehicle.
Range
Set
Example:
FUNCTION 5
PLUGGING CURRENT LIMIT
(Push 5)
This function allows for the adjustment of the plugging
distance of the vehicle. The larger the current setting, the
shorter the stopping distance.
Min
Max
Set
55
455
0 to 255
Important Note: The function is used to optimize motor and
control performance and this setting will be determined by
GE and OEM engineers at the time of vehicle development.
This setting must not be changed by field personnel without
the permission of the OEM.
Page 60
0.05% per set unit
Setting of 20 = 3% on time
0.1 to 25.5 seconds
1 to 255
0.1 seconds per set unit
Setting of 20 = 2.0 seconds
C/A and 1A Time = 2.2 seconds
See control C/L curves
0 to 255
0 = min. current,
255 = max. current
Resolution
Example
Per unit value
If set at 20
1.57 amps
86.4 amps
January 1999