9.9 Opening the Cover Plate of an RRU Cabling Cavity

This section describes the procedure for opening the cover plate of an RRU cabling cavity.
Procedure
Step 1 Wear ESD gloves.
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.
Step 2 Use an M5 Phillips screwdriver to loosen the three screws on the cover plate of the RRU cabling
cavity, and open the cover plate, as shown in
Figure 9-21 Opening the cover plate of the RRU cabling cavity
(1) Cover plate
(4) Cable trough for the power cable
Issue 01 (2014-11-20)
NOTICE
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9.1 Cabling
Figure
9-21.
(2) Cabling cavity
(3) Clip
(5) Waterproof block (6) Cable trough for the fiber optical cable