Eagle-100 Series Eagle-100 Series Eagle-200 Series Eagle-200 Series Swing Gate Operators ACCESS CONTROL SYSTEMS, INC. Made in the USA Diamond Control Board or Diamond DC Control Board I N C Installation & Owners Manual UL 325 Compliant / UL 991 Compliant...
WILL vary Eagle-100 Series residential. depending on length and weight of the gate. BY EAGLE ACCESS CONTROL SYSTEMS, INC. 28” 18.5” 16” Commercial Swing Gate Operators Model Motor(s) Power Max Length Max Weight Control Board Operation Battery Back-Up &...
Page 5
SAFETY Requirements for UL 325 Compliant Installation 1. Install the gate operator only when: a) The operator is appropriate for the construction of the gate and the usage class of the gate. b) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22 m) above the ground to prevent a 2-1/4 inch (57.2 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position.
Page 6
UL 325 Model Classifications CLASS I CLASS I Residential Vehicular Gate Operator - A vehicular gate operator (opener or system) intended for use in a home of one to four single family dwellings, or a garage or parking area associated therewith. CLASS II CLASS II Commercial/General Access Vehicular Gate Operator - A...
Page 7
General Safety Information CAUTION Be sure to read and follow all the Eagle Access Control Systems, Inc. and UL instructions before installing and operating any Eagle Access Control System, Inc. products. Eagle Access Control Systems, Inc. is not responsible for any improper installation procedures caused by failure to comply with local building codes.
An experienced installer should perform the installation. Improper installation may result in property damage, severe injury or death. Read the entire manual before proceeding with the installation. Eagle Access Control Systems, Inc. is not responsible for researching and complying with local building codes. Be sure to check all local building codes before installation.
Support Bar Gate Arms MUST be Level! Attachment Bracket BY EAGLE ACCESS CONTROL SYSTEMS, INC. Weld completely around gate attachment bracket AFTER arm measurements have been determined. COMMON MISTAKES TO BE AWARE OF: Closed Gate DO NOT allow arms to scissor when the gate is fully open.
SOLAR-ONLY LOOP DETECTOR POWER NOTE: It is recommended using Eagle plug-in loop detectors when using solar-only power. External loop detectors require a separate power source which is usually not available when a solar-only configuration is used.
In-Ground Loop Wires Connection LOOP Please call Connect in-ground loop wires to SHADOW Eagle LOOP corresponding loop detector Only when Access EXIT using Eagle Plug-In Loop Detectors. OPEN before any adjustment. REVERSE SHADOW EXIT See page 12. Eagle Plug-In EG167...
All operators MUST be properly grounded. Installing surge protection is recommended. 120 VAC power WARNING: Eagle Access Control Systems, Inc. is not responsible for outlet provided. researching and complying with local building codes. Be sure to check all local building codes before installation.
Diamond Board ONLY Emergency Release Unscrew bolt, remove top cap and rotate easy release lever. These two gaps should remain even for proper fit. IN C Adjusting the Clutch Depending on the weight of the gate, clutch slippage may occur. Typical clutch slippage is about 1/4 turn.
LED warning light will light up when Factory Set ERD Sensor “Fine Tune” Adjustment: the gate is heavier than normal for the Please call Eagle Access before adjusting this sensor! operator. During this warning, the Fine tune adjustment is ONLY necessary when stopping force operator will NOT function properly.
Diamond Board ONLY Global Input Descriptions #2 REVERSE LOOP: Momentary or continuous signal - This input is active only when the gate is closing or when its fully open, if this input is active. The close timer is disabled. Vehicle loop detectors and photo sensors should be connected here.
Diamond Board ONLY Connecting Accessories GLOBAL INPUTS OUTPUTS Safety Equipment Maglock External Reverse Loop 24 VDC Detector a t e p a r Safety Equipment Edge External Phantom Sensor Loop (Shadow Loop) Detector a t e T r a p a r n s m i t t e Photocell Sensor...
Diamond Board Master / Slave Setup Opens to the Left Opens to the Right MASTER SLAVE BY EAGLE ACCESS CONTROL SYSTEMS, INC. BY EAGLE ACCESS CONTROL SYSTEMS, INC. Operator Operator IMPORTANT: The 115 VAC power for the master and slave operators MUST be on the same circuit breaker.
• Safety external loop detector must be connected to the “REVERSE LOOP” input (see pages 13 & 14). • If the CLOSE TIMER feature is desired, switch #8 MUST be in the “ON” position. • It is OK to call the Eagle Access Customer Service Department with any questions... we are here to serve YOU! 1-800-708-8848...
Diamond Board ONLY Eagle-100 / Eagle-200 Models Wiring Diagram Limit Switches Radio ReceiverTerminal (24V) Wire RADIO POWER RELAY COMMON GROUND Orange N.O. (Top Switch) (24V) Wire RADIO POWER RELAY RELAY RET Green Com Yellow N.O. (Bottom Switch) Diamond Board SELECT...
EXIT LOOP 24 VDC Output If using optional solar power, Loop Detector RELAY CHARGER Radio BATTERY RELAY “Remains ON” use only Eagle 24 V Solar Power 24VDC + – Automatically adjusts for Receiver Power Save Mode Indicator -24VDC Panels (EG-510-10 watt,...
Diamond DC Board ONLY Feature Selector Switches #1 - #8 SELECT The Feature Selector Descriptions: SLAVE MASTER OPEN LEFT OPEN RIGHT NOTE: The power MUST be turned OFF before changing the features selector switches. BRAKE OFF BRAKE ON REVERSE LOOP NO REVERSE LOOP NC ONE PASS OFF ONE PASS ON...
Battery Replacement When Necessary Normal battery deterioration will take place over time and batteries will need to be replaced eventually. Remove the 5-Pin Primary Connector (White Plug) from Diamond DC Board BEFORE replacing the Eagle Battery Pack. IMPORTANT: Use only Eagle Battery Pack in your Eagle gate operator.
Diamond DC Board ONLY Diamond DC Board 120/240 VAC Input Power Connection WARNING: Eagle Access Control Systems, Inc. is not responsible for researching and complying with local building codes. Be sure to check all local building codes before installation. CAUTION...
Diamond DC Board ONLY Emergency Release Unscrew bolt, remove top cap and rotate easy release lever. These two gaps should remain even for proper fit. IN C Adjusting the Clutch Depending on the weight of the gate, clutch slippage may occur. Typical clutch slippage is about 1/4 turn.
Factory Set ERD Sensor “Fine Tune” Adjustment: operator. During this warning, the Please call Eagle Access before adjusting this sensor! operator will NOT function properly. Fine tune adjustment is ONLY necessary when stopping force cannot be achieved within normal reverse sensor ERD range.
Diamond DC Board ONLY Global Input Descriptions #2 REVERSE LOOP: Momentary or continuous signal - This input is active only when the gate is closing or when its fully open, if this input is active. The close timer is disabled. Vehicle loop detectors and photo sensors should be connected here.
Diamond DC Board ONLY Connecting Accessories MAG LOCK GLOBAL INPUTS OUTPUTS Safety Equipment Maglock External Reverse Loop 24 VDC Detector a t e p a r Safety Equipment Edge External Shadow Loop Sensor Detector a t e T r a p a r n s m i t t e...
Diamond DC Board Master / Slave Setup Opens to the Left Opens to the Right MASTER SLAVE BY EAGLE ACCESS CONTROL SYSTEMS, INC. BY EAGLE ACCESS CONTROL SYSTEMS, INC. Operator Operator IMPORTANT: The 115 VAC power for the master and slave operators MUST be on the same circuit breaker.
• Safety external loop detector must be connected to the “REVERSE LOOP” input (see pages 25 & 26). • If the CLOSE TIMER feature is desired, switch #8 MUST be in the “ON” position. • It is OK to call the Eagle Access Customer Service Department with any questions... we are here to serve YOU! 1-800-708-8848...
Diamond DC Board ONLY Eagle-100-DC / Eagle-200-DC 120 VAC Input Models Wiring Diagram Limit Switches Radio ReceiverTerminal (24V) Wire RADIO POWER RELAY COMMON GROUND 115 VAC (24V) Outlet Wire RADIO POWER RELAY RELAY RET Yellow N.O. (Top Switch) Green Com White Orange N.O.
Diamond DC Board ONLY Eagle-100-DC / Eagle-200-DC 240 VAC Input Models Wiring Diagram Limit Switches Radio ReceiverTerminal (24V) Wire RADIO POWER RELAY COMMON GROUND 115 VAC (24V) Outlet Wire RADIO POWER RELAY RELAY RET Yellow N.O. (Top Switch) Green Com White Orange N.O.