14.8 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)

A. Purpose
To provide quiet cooling operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When "POWERFUL/QUIET" button at remote control is pressed twice.
o
QUIET will be shown on remote control display.
o
b. Quiet operation stop condition
1
When one of the following conditions is satisfied, quiet operation stops:
a. POWERFUL/QUIET button is pressed again.
b. Stop by OFF/ON switch.
c.
Timer "off" activates.
d. +8/15°C HEAT ON
2
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5
During quiet operation, if timer "on" activates, quiet operation maintains.
6
After off, when on back, quiet operation is not memorized.
C. Control contents
1
Fan speed is changed to Lo-.

14.9 Quiet Operation (Heating)

A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When "POWERFUL/QUIET" button at remote control is pressed twice.
o
QUIET will be shown on remote control display.
o
b. Quiet operation stop condition
1
When one of the following conditions is satisfied, quiet operation stops:
a. POWERFUL/QUIET button is pressed again.
b. Stop by OFF/ON switch.
c.
Timer "off" activates.
d. +8/15°C HEAT ON
2
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3
When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5
During quiet operation, if timer "on" activates, quiet operation maintains.
6
After off, when on back, quiet operation is not memorized.
C. Control contents
a. Fan Speed manual
1
Fan speed is changed to Lo-.
b. Fan Speed Auto
1
Fan speed is changed to Lo-.

14.10 Powerful Mode Operation

When the powerful mode is selected, the internal setting temperature will shift lower up to 1°C (for Cooling/Soft
Dry) or higher up to 1°C (for Heating) than remote control setting temperature to achieve the setting temperature
quickly.
60

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

Cs-cz25tkeCs-cz35tkeCu-cz35tke

Table of Contents