Time And Polarities Of The Alarm/Control Connector - Panasonic WJ-NX400K/GJ Installation Manual

Network disk recorder
Hide thumbs Also See for WJ-NX400K/GJ:
Table of Contents
3 Connections

Time and polarities of the ALARM/CONTROL connector

Terminal name
Alarm input
Alarm reset input
Emergency recording input
Outage detection input
External recording mode
switching input
Network error output
HDD error output
Camera error output
Recording error output
Recorder error output
Outage processing end out-
put
Alarm output
Time adjustment I/O
* The error output duration is configured on the "Advanced setup" menu - the "Maintenance" page - "System setup" of the setup
menu. (☞ Operating Instructions (PDF))
Note:
• During "L active (Low active)", the logic will be implemented when the voltage level of signal is low.
• During "H active (High active)", the logic will be implemented when the voltage level of signal is high.
26
(continued)
Active Time
100 ms or more
100 ms or more
100 ms or more
5 s or more
100 ms or more
At an error occurrence until the period selected for "Error out-
put duration" has passed*
At an error occurrence until the period selected for "Error out-
put duration" has passed*
At an error occurrence until the period selected for "Error out-
put duration" has passed* or the camera reset
At an error occurrence until the period selected for "Error out-
put duration" has passed*
At an error occurrence until the period selected for "Error out-
put duration" has passed*
10 s or more
The set time on the setup menu
Input: 100 ms or more
Output: The set time on the setup menu
Remarks
N.O.: L active
N.O.: H active
L active
L active
L active
L active
L active
L active
L active
L active
L active
H active
L active
Input/Output: L active