Toshiba RAS-2M14U2AVG-E Service Manual page 54

Hide thumbs Also See for RAS-2M14U2AVG-E:
Table of Contents
8-2.Outdoor Unit (Inverter Assembly)
RAS-2M18U2AVG-E,-TR
Outdoor temp. sensor
A unit P.M.V.
B unit P.M.V.
MCC-1646
(Display-P.C.B)
LED
Tact-SW
Jumper
Noise filter
Input current
Sensor
Converter
(AC→DC)
Inverter
(DC→AC)
Output current
sensor
Compressor
Gas side pipe temp. sensor
Driver
circuit
of P.M.V.
High power factor
correction circuit
Gate drive
circuit
Suction temp. sensor
M.C.U
・Inverter outdoor frequency control
・A/D converter function
・P.M.V control
・Processing (Temp. Processing)
・Error display
・ Serial Signal Communication with
indoor unit
・Signal Communication with MAIN-P.C.B
・Function select
Function select
Signal Communication
M.C.U
・PWM synthesis function
・Input current release control
・IPM over current detect control
・High power factor correction control
・Signal Communication with
Control-P.C.B
・Fan motor control
・Compressor motor control
・4-way valve control
・High-pressure switch
・Case thermo
Inverter
(DC→AC)
Output current
sensor
Outdoor
fan motor
- 54 -
FILE NO. SVM-18020-2
Evaporator temp. sensor
MCC-1665 (Control P.C.B)
A unit Serial Signal
Communication
circuit
B unit Serial Signal
Communication
circuit
220-240V ~50Hz
220V ~60Hz
MCC-1645 (MAIN P.C.B)
High-pressure switch
Case thermo
Clock frequency
oscillator
circuit 10MHz
Gate drive
circuit
P.M.V:Pulse motor valve
PWM :Pulse width modulation
IPM :intelligent power module
Discharge temp. sensor
Relay circuit
4-way valve
Table of Contents