Emerson RIDGID PCRP Operating Instructions & Parts Manual

Emerson RIDGID PCRP Operating Instructions & Parts Manual

Self-priming portable utility pump with case
Table of Contents
Available languages

Available languages

Quick Links

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.
Failure to follow these instructions could result in property damage, serious injury or death.
DESCRIPTION
This self-priming portable utility pump is designed to be used as
a transfer pump for such applications as emptying water heaters,
livestock tanks, etc. Pump can also be used for an intermittent
pressure boost for applications such as washing cars, cleaning
driveways, etc. The motor is air cooled; it is not designed to operate
under water.
NOTE: This pump is not intended for permanent installation or long,
extended periods of continuous operation.
UNPACKING
After unpacking the utility pump, carefully inspect for any damage
that may have occurred during transit. Check for loose, missing or
damaged parts. If you need assistance, call our Customer Service
Department at 1-877-9RIDGID.
SAFETY GUIDELINES
To help recognize this information, observe the following signal
words/hazard classifications.
Danger indicates an imminently hazardous
situation which, if not avoided, WILL result in
death or serious injury.
Warning indicates a potentially hazardous
situation which, if not avoided, COULD result in
death or serious injury.
Caution indicates a potentially hazardous
situation which, if not avoided, MAY result in
minor or moderate injury.
Notice indicates important information, that if
not followed, may cause damage to equipment.
This is the safety alert symbol. It is used to alert you to potential bodily
injury hazards. Obey all safety messages that follow this symbol to avoid
possible harm.
NOTE: Information that requires special attention.
Motor
Single Phase - 115V, 60 Hz, 8,000 RPM
Motor
Series Wound (brush type) AC/DC Operation
Impeller
Thermoplastic
Motor Housing
Cast iron
Shaft and Volute
Buna-N
Seal
Maximum Fluid
120°F
Temperature
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2017, Ridge Tool Company.
Self-Priming
Portable Utility Pump with Case
OPERATING INSTRUCTIONS & PARTS MANUAL
GENERAL SAFETY INFORMATION
GENERAL SAFETY
WILL result.
Do NOT use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do NOT use in a flammable
and/or explosive atmosphere. Pump SHOULD only be used to
pump clear water. Personal injury and/or death WILL result.
Do NOT walk on wet areas until ALL power is turned off.
Failure to follow this warning WILL result in fatal electrical
shock.
1.
Read all instructions before operation.
2.
Disconnect power and release all pressure within
the system before servicing any component.
3.
Drain all liquids from system before servicing.
Personal injury and/or property damage COULD result.
4.
Periodically inspect pump and system components, checking
for weak and/or worn hoses. Insure all connections are secure.
Specifications
Horsepower
Inlet/Outlet Openings
Pump Housing
Motor Shaft
Motor Bearings
Do not submerge motor or allow motor to be
exposed to water. Personal injury and/or death
Risk of electrical shock. ALL wiring must be
performed by a qualified electrician.
Secure the discharge line before starting the
pump. An unsecured discharge line MAY whip.
1/2 HP
3/4 inch NPT
Cast iron
Cold rolled steel
Permanently lubricated
Rolling element bearings
3213
05
PCRP
-005 A 8/17
Table of Contents
loading

Summary of Contents for Emerson RIDGID PCRP

  • Page 1 Self-Priming Portable Utility Pump with Case OPERATING INSTRUCTIONS & PARTS MANUAL READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD. Failure to follow these instructions could result in property damage, serious injury or death. PCRP DESCRIPTION GENERAL SAFETY INFORMATION This self-priming portable utility pump is designed to be used as GENERAL SAFETY...
  • Page 2: Installation

    Operating Instructions and Parts Manual GENERAL SAFETY INFORMATION (CONTINUED) INSTALLATION Pump motor is equipped with an automatic resetting thermal protector and MAY restart unexpectedly. Protector tripping is an indication of motor overheating ALWAYS disconnect power source before attempting to because of operating pump at low heads (low discharge restriction), operate, service, or maintain the pump.
  • Page 3: Maintenance

    PCRP MAINTENANCE PRIME PLUG Let pump cool for at least 20 minutes before attempting to service. Motor MAY be extremely hot. Personal injury MAY result. INLET Pump should be checked periodically for proper operation. ALWAYS disconnect the electrical supply before attempting to operate, service, or perform any maintenance.
  • Page 4: Service Part Replacement

    Operating Instructions and Parts Manual SERVICE PART REPLACEMENT Make sure the pump is unplugged and cooled down before ROTOR ASSEMBLY THRUST WASHER disassembling the pump. Release any pressure from the pump then disconnect any hoses or plumbing, and drain the product. HEAD SEAL Remove brush holder caps and brushes (make note of which CERAMIC SEAL...
  • Page 5: Troubleshooting Chart

    PCRP TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Blown fuse 1. If blown, replace with proper sized fuse or reset breaker 2. Low line voltage 2. Contact an electrician 3. Worn brushes 3. Replace brushes 4.
  • Page 6: Replacement Parts List

    Operating Instructions and Parts Manual For Replacement Parts or Technical Assistance, Call 1-877-9RIDGID Please provide following information: Address parts correspondence to: - Model number RIDGID PUMPS - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Page 7 PCRP NOTES...
  • Page 8 Models - PCRP Warranty & Service Parts Sheet RIDGID Water Pump PCRP Limited One Year Warranty. This product is manufactured by WAYNE Water Systems. The trademark is licensed from Ridge Tool Company. All warranty communications should be directed to RIDGID customer service at 1-877-9RIDGID. What is Covered under the Limited One Year Warranty RIDGID water pumps are warranted to be free of material and workmanship defects for the one-year period from the date of purchase.
  • Page 9: Para Desempacar

    Bomba de utilidad portátil auto- cebadora con caja MANUAL DE INSTRUCCIONES DE FUNCIONAMIENTO Y EZAS DE REPUESTOI LEA, ENTIENDA Y SIGA TODAS LAS INSTRUCCIONES DE ESTE MANUAL. NO LO DESECHE. . LEA, ENTIENDA Y SIGA TODAS LAS INSTRUCCIONES DE ESTE MANUAL. NO LO DESECHE. . No seguir estas instrucciones podría provocar daño a la unidad, lesiones graves o la muerte.
  • Page 10: Instalación

    Manual de instrucciones de funcionamiento y piezas de repuesto INFORMACIONES GENERALES DE SEGURIDAD Tabla de las Longitudes de los Cordones de Extensión (CONTINUACION) Tamaño del Asegure la línea de descarga antes de dar alambre arranque a la bomba. Si no la asegura, ES Longitud 15 m 31 m...
  • Page 11 PCRP Quítele el tapón al sistema de cebado y llénelo de agua. Vuelva a NOTAS colocar el tapón (se debe usar cinta de sellado de plomería en el tapón de cebado para evitar fugas de aire). __________________________________________________________ Conecte el cordón eléctrico a un tomacorrientes con cortacircuito automático con conexión a tierra.
  • Page 12 Operating Instructions and Parts Manual REEMPLAZO DE PIEZAS DE REPUESTO Asegúrese de que la bomba esté desconectada y fría antes de ENSAMBLE DEL desarmarla. ARANDELA DE ROTOR EMPUJE Libere toda la presión de la bomba y luego desconecte las mangueras o tuberías, y drene el producto. SELLO DE Retire las tapas de los soportes de las escobillas y las escobillas CEBEZAL...
  • Page 13 PCRP TABLA DE IDENTIFICACIÓN DE PROBLEMAS Síntoma Causa(s) Posible(s) Medida Correctiva La bomba no se 1. Un fusible quemado 1. Si está quemado, reemplácelo con un fusible enciende ni funciona adecuado o active el cortacircuito 2. El voltaje es muy bajo 2.
  • Page 14: Lista De Partes De Reparación

    Manual de instrucciones de funcionamiento y piezas de repuesto Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al Distribuidor Más Cercano a Su Domicilio Distribuidor Más Cercano a Su Domicilio Sirvase darnos la siguiente información: Dirija toda la correspondencia a: - Número del modelo RIDGID PUMPS...
  • Page 15 PCRP NOTAS Sp-15...
  • Page 16 Modelo – PCRP Hoja de garantía y piezas de repuesto RIDGID Bomba de agua R12V limitada Garantía de un año. Este producto es fabricado por WAYNE Water Systems. La marca comercial está registrada con licencia de Ridge Tool Company. Todas las comunicaciones referentes a la garantía deben dirigirse al servicio de atención al cliente de RIDGID al 1-877-9RIDGID.

Table of Contents