Technical Data; Piping Diagram: Indoor Unit - Daikin Altherma R Hybrid Installer's Reference Manual

Hide thumbs Also See for Altherma R Hybrid:
Table of Contents

15 Technical data

15.1 Piping diagram: Indoor unit

A
13
14
15
1
3
2
3
A Water side
B Refrigerant side
1 Space heating water IN
2 Space heating water OUT
3 Shut‑off valve with drain/fill valve
4 Expansion vessel
5 Filter
6 Pump
7 Plate heat exchanger
8 Air purge
9 Flow sensor
10 3‑way valve
11 Safety valve
12 Gas boiler
13 Domestic hot water: hot water OUT
14 Gas pipe
15 Domestic hot water: hot water IN
16 R1T – Plate heat exchanger outlet water thermistor
17 R2T – Outlet water thermistor
18 R3T – Heat exchanger liquid pipe thermistor
19 R4T – Inlet water thermistor
20 Screw connection
Screw connection
CHYHBH05+08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
A subset of the latest technical data is available on the regional Daikin website
(publicly accessible). The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
12
11
17
10
20
4
5
B
9
8
16
6
19
15
Technical data
|
7
18
3D082238-1B
Installer reference guide
191

Hide quick links:

Table of Contents
loading

Table of Contents