Vaillant eloSTOR Exclusive VEH 50/8-7 Installation And Maintenance Instructions Manual

Vaillant eloSTOR Exclusive VEH 50/8-7 Installation And Maintenance Instructions Manual

Installation and maintenance instructions
Publisher/manufacturer
Vaillant GmbH
Berghauser Str. 40
D-42859 Remscheid
Tel. +49 21 91 18‑0
Fax +49 21 91 18‑2810
www.vaillant.de
eloSTOR exclusive
VEH 50–120/8-7
AT, DE
Table of Contents
loading

Summary of Contents for Vaillant eloSTOR Exclusive VEH 50/8-7

  • Page 1 Installation and maintenance instructions eloSTOR exclusive VEH 50–120/8-7 AT, DE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18‑0 Fax +49 21 91 18‑2810 [email protected] www.vaillant.de...
  • Page 2: Table Of Contents

    Contents Contents Maintenance plan..........17 Technical data............ 17 Safety ..............3 Action-related warnings ......... 3 Intended use ............3 General safety information ........3 Regulations (directives, laws, standards) ....4 Notes on the documentation ......5 Observing other applicable documents ....5 Storing documents..........
  • Page 3: Safety 1

    Safety 1 as vehicles are those that are installed in Safety a fixed and permanent location (known as Action-related warnings "fixed installation"). Classification of action-related warnings Any other use that is not specified in these in- The action-related warnings are classified in structions, or use beyond that specified in this accordance with the severity of the possible document shall be considered improper use.
  • Page 4: Regulations (Directives, Laws, Standards)

    1 Safety port the operating weight of the product. An Regulations (directives, laws, standards) uneven installation surface may cause leaks in the product. ▶ Observe the national regulations, stand- There is a risk of death if the connections are ards, guidelines and laws. subject to leaks.
  • Page 5: Notes On The Documentation

    Notes on the documentation 2 Notes on the documentation Design Observing other applicable documents ▶ You must observe all the operating and installation in- structions included with the system components. Storing documents ▶ Pass these instructions and all other applicable docu- ments on to the system operator.
  • Page 6: Requirements For The Installation Site

    Install a suitable safety group on the VEH's water con- nections. ▶ Replace the connectors from the safety group with the connectors supplied for the VEH 80: – Vaillant connection pipe 0020192421 – Vaillant connection pipe 0020192422 Installation and maintenance instructions eloSTOR exclusive 0020234040_02...
  • Page 7: Installation

    Installation 5 ▶ Install components (1) to (7). Conditions: The wall is uneven. ▶ Install the safety device as close as possible to the pro- duct's cold water inlet. ▶ Install the drain pipework at a constant incline. ▶ Maintain a clearance between the expansion relief valve's discharge pipe and the tundish so that the drain pipework is open to the atmosphere.
  • Page 8: Electrical Installation

    6 Start-up Electrical installation Re-work ▶ Using an indelible pen, note the connected power on the identification plate. Start-up Open the cold water stop cock. Open the hot water valves. Wait until water flows out of the hot water valves. Close the hot water valves.
  • Page 9: Checking That The Product Works Correctly

    Handing over to the operator 7 Checking that the product works correctly Disconnecting the product from the power supply Set the maximum flow temperature on the domestic hot water cylinder. Danger! ◁ The display shows the "Heating element active" Risk of electric shock symbol There is a risk of electric shock when working Open the hot water draw-off point that is furthest away...
  • Page 10: Checking The Inner Vessel And Components For Scale Deposition

    9 Troubleshooting Installing the flange Replacing a defective heating element 10. Replace the flange seal. Disconnect the product from the power supply. 11. Check the inner vessel and components for scale de- (→ Page 9) position. (→ Page 10) Empty the product. (→ Page 10) 12.
  • Page 11: 12 Customer Service

    Anrufen aus dem Mobilfunknetz ggf. abweichende Tarife - nähere Information erhalten Sie bei Ihrem Mobilnetzbe- treiber) Der flächendeckende Kundendienst für ganz Österreich ist täglich von 0 bis 24 Uhr erreichbar. Vaillant Kundendienst- techniker sind 365 Tage für Sie unterwegs, sonn- und feier- tags, österreichweit. Applicability: Germany Auftragsannahme Vaillant Kundendienst: 021 91 5767901...
  • Page 12: Appendix

    Appendix Appendix Fault display view Display Cause Remedy – Dry fire Check all of the product's components for malfunctions. The display lights up for 30 seconds. Fault Repair or replace the defective compon- The display remains permanently on. ent. Press and hold the buttons at the same time for 5 seconds to ac- knowledge the fault...
  • Page 13: C Dimensions And Dimension Drawing

    Appendix Dimensions and dimension drawing R ½ Dimensions VEH 50/8-7 VEH 80/8-7 VEH 100/8-7 VEH 120/8-7 637 mm 875 mm 1,041 mm 1,207 mm 529 mm 673 mm 759 mm 759 mm 0020234040_02 eloSTOR exclusive Installation and maintenance instructions...
  • Page 14: Circuit Diagrams And Electrical Connections

    Appendix Circuit diagrams and electrical connections Connection diagram 16 A EVU contact Heating elements Mains connection terminal Output selection terminal Safety cut-out Fuse Control system relay Smart control interface module Isolating plug Smart control power module Protection anode earthing Low tariff output Vessel earthing High tariff output Functional earth resistor...
  • Page 15: Overview Of The Configuration Types

    Appendix Overview of the configuration types On-demand Single circuit Twin circuit switching (Co2) switching (Co0) switching (Co1) Available operating Scald protection Scald protection Scald protection Smart mode Manual Manual Manual Smart EVU contact Not working Not working Open: High tariff Closed: Low Not working tariff...
  • Page 16 Appendix Heating element VEH 50 / 80 / 100 VEH 120 1 kW 1.5 kW 2 kW 1.5 kW 2 kW 1.5 kW 1 kW 1.5 kW Configuration type Mains connection Basic load Rapid heating – – Twin-circuit switching VEH 50/8-7 VEH 50/8-7 –...
  • Page 17: Contents E Maintenance Plan

    Appendix Maintenance plan Maintenance work Interval Checking the magnesium protection anode After the first two years, then annu- ally thereafter Checking seals Each time maintenance work is carried out Tighten the fixing screws Each time maintenance work is carried out Checking the inner vessel and components for scale deposition Each time maintenance work is carried out...
  • Page 20 Telefon 05 7050‑2100 (zum Regionaltarif österreichweit, bei Anrufen aus dem Mobilfunknetz ggf. abweichende Tarife - nähere Information erhalten Sie bei Ihrem Mobilnetzbetreiber) [email protected] [email protected] www.vaillant.at www.vaillant.at/werkskundendienst/ Vaillant Deutschland GmbH & Co.KG Berghauser Str. 40 D-42859 Remscheid Telefon 021 91 18‑0 Telefax 021 91 18‑2810 Auftragsannahme Vaillant Kundendienst 021 91 5767901 [email protected]...