Section 14, Maintenance Schedule - Gardner Denver VST110 Operating And Service Manual

Ariable speed two-stage stationary base-mounted compressor
Table of Contents
SECTION 14
MAINTENANCE SCHEDULE
SERVICE CHECK LIST
Daily Checks:
·
Air Filters (Compressor) - Replace when controller displays "CHANGE AIR FILTER" message.
Refer to Section 7, page 55 for air filter details.
·
Oil Separator Element - Replace when controller displays "CHANGE OIL SEPARATOR ELEMENT".
Refer to Section 5, page 42 for oil separator element details.
·
Air/Oil Reservoir Oil Level - Check the reservoir oil level during compressor operation only - add oil
if required. Refer to Section 5, page 42 for full details. DO NOT MIX LUBRICANTS.
·
Start/Modulation/Stop Operation – Verify that compressors maintain steady compressed air
pressure.
·
AirSmart Operational Parameters – Maintaining a periodic log of package critical parameters (e.g.,
pressures, temperatures, speeds, load levels, etc) helps identify when abnormal operation occurs.
·
AirSmart Controller Messages and Alarms – Acknowledge the presence of an abnormal condition
and take action to correct it.
Weekly Checks:
·
Heat Exchangers (air-cooled) - Check for dirt accumulation on (air-cooled) air/oil heat exchanger
finned surfaces. Refer to Section 6, page 50 for detailed instructions to clean heat exchanger
surfaces.
·
Axial cooling fans – Check for grime and dirt build-up on fan blade surfaces. Refer to
Section 6 for detailed instructions to clean axial cooling fan blade surfaces
·
Air Filters (Electrical Box) – Check filter elements for dirt accumulation. Refer to Section 7, page 55
for detailed instruction to clean filter elements.
Every 1000 Hours:
·
Oil Filter - Replace.
·
Oil - Sample and analyze.
Every 8000 Hours (Or as Prescribed by Oil Analysis Results):
Compressor Lubricant – Replace.