Location - Stuart Turner MAINSBOOST MB 100CV Installation, Operation & Maintenance Instructions Manual

Table of Contents
3 LOCATION - GENERAL
3.11 Access: For emergencies and maintenance the Mainsboost must
3.12 Protection: The system must be located in a dry position, and
3.13 Incoming mains water pressure: An incoming water pressure of at least 2.0
bar is required and should not exceed 5 bar. (If mains pressure is below 2.0
bar the Mainsboost vessel should be supplemented with a pump unit, contact
Stuart Turner for details).
3.14 Ensure that location of the unit allows adequate space to give reasonable
access to all parts to accommodate service/commissioning.
3.15 Pipework: Pipework should be sized to ensure optimum performance of the
system.
3.16 Direction of flow: See Fig. 3 to identify the suction and discharge
connections.
be easily accessible.
protected from freezing. Avoid environments which have a high
ambient temperature, high humidity or excessive condensation
and salt damage, etc.