Emerson Fisher 1301 Series Manual

Emerson Fisher 1301 Series Manual

High-pressure regulators

Quick Links

1301 Series High-Pressure Regulators
WARNING
!
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
fire and/or chemical contamination
causing property damage and personal
injury or death.
Fisher
®
regulators must be installed,
operated and maintained in accordance
with federal, state and local codes, rules
and regulations and Fisher instructions.
If the regulator vents gas or a leak
develops in the system, service to the unit
may be required. Failure to correct trouble
could result in a hazardous condition.
Installation, operation and maintenance
procedures performed by unqualified
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Use qualified
personnel when installing, operating
and maintaining the 1301 Series high-
pressure regulator.
Introduction
Scope of the Manual
This Instruction Manual provides instructions for the
installation, adjustment, maintenance and parts ordering
of the Types 1301F and 1301G high-pressure regulators.
Product Description
Types 1301F and 1301G regulators are direct-operated,
high-pressure regulators, which can be used where
high-pressure gas must be reduced for use as pilot
supply pressure in pilot-operated regulators or as
loading pressure in pressure-loaded regulators.
44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170.
website:
https://www.add-furnace.com/
Line ID: @add11 e-mail: [email protected]
P1025
Figure 1. Type 1301F High-Pressure Regulator
Types 1301F and 1301G regulators can also be used
in many other applications due to their rugged design
as high-pressure reducing regulators for various fluids
such as air, gas, water and other liquids.
The Type 1301F can handle outlet pressures from 10 to
225 psig / 0.69 to 15.5 bar in three ranges and the
Type 1301G can handle outlet pressures from 200 to
500 psig / 13.8 to 34.5 bar in one range.
www.fisherregulators.com
โทร: 02-888-3472
Table of Contents
loading

Summary of Contents for Emerson Fisher 1301 Series

  • Page 1 44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] 1301 Series High-Pressure Regulators WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion, fire and/or chemical contamination causing property damage and personal injury or death.
  • Page 2: Specifications

    44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] Specifications Specifications section lists the specifications for Types 1301F and 1301G high-pressure regulators. The maximum outlet pressure for a given regulator as it comes from the factory is stamped on the regulator nameplate. Available Configurations IEC Sizing Coefficients Type 1301F: Direct-operated, high-pressure reducing...
  • Page 3: Principle Of Operation

    44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] CONTROL SPRING DIAPHRAGM DISK HOLDER VALVE DISK SPARE DISK VALVE SPRING BOTTOM CAP M1015 INLET PRESSURE OUTLET PRESSURE ATMOSPHERIC PRESSURE Figure 2.
  • Page 4: Installation

    44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] to the Startup section. In all cases, check the spring Installation setting to make sure it is correct for the application. WARNING Overpressure Protection Overpressuring a regulator or...
  • Page 5: Parts Ordering

    44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] Regulator parts are subject to normal wear and must be 10. Unscrew the orifice (key 5). Examine seating inspected and replaced as necessary. The frequency edge of orifice.
  • Page 6 44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] NOTE: OPTIONAL THIRD OUTLET CD3923_F Figure 3. Type 1301F High-Pressure Regulator Assembly BP6341-A CN7095_C Figure 4. Type 1301G High-Pressure Regulator Assembly Figure 5.
  • Page 7: Parts List

    44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] Description Part Number pertinent information stamped on the bottom cap and on the nameplate. Specify the complete 11-character Spring Case (continued) part number from the following parts list when ordering Type 1301G 1/8 NPT vent connection...
  • Page 8 44 ซ.บรมราชชนนี 70 ถ.บรมราชชนนี ศาลาธรรมสพน์ ทวี ว ั ฒ นา กทม. 10170. website: https://www.add-furnace.com/ โทร: 02-888-3472 Line ID: @add11 e-mail: [email protected] Description Part Number Description Part Number Machine Screw (2 required) Screw, Steel (Not shown) Steel, for brass yoke 1H526928982 Type 1301F with handwheel and steel 302 Stainless steel, for Stainless steel yoke 1J926938992...

This manual is also suitable for:

Fisher 1301fFisher 1301g

Table of Contents