Honeywell 6280 Installation Manual

Honeywell 6280 Installation Manual

Touchcenter keypads
Hide thumbs Also See for 6280:

Quick Links

6280 TouchCenter Keypads
Installation Guide
For Online Support visit: http://www.security.honeywell.com/hsc/resources/MyWebTech/
General Information
This guide provides information on installing and setting up Honeywell's
6280 TouchCenter Keypads. The 6280 Series graphical touch-screen
keypads are Advanced User Interface (AUI) devices, which combine
control of your security system, multi-media and premises lighting.
Compatibility: For a list of alarm systems that the TouchCenter can
interface with, refer to the Compatibility Table in this document.
Wiring
IMPORTANT: If you power the TouchCenter from your panel's auxiliary
power output, check your panel's Installation and Setup Guide and verify
that this device and others do not exceed your panel's auxiliary power
output capability; if it does, a supplementary power supply is needed.
Word List
The 6280 TouchCenter can annunciate a series of words. You must use
the vocabulary list in your alarm panel instructions for actual words that
may be annunciated; refer to the Word List in this document.
This Keypad is for indoor use only and should be mounted at a comfortable viewing level. Avoid mounting in areas of
high condensation such as bathrooms or in locations where bright light or sunlight shines directly on the screen. The
TouchCenter can be mounted with or without the mounting plate. Use the center securing screw for European installation.
Standard Mounting with mounting plate:
1. Select a mounting location.
2. Detach the mounting plate by sliding downward.
3. Use the mounting plate to mark the location of the mounting
holes on the mounting surface and check for level.
4. Locate the mounting plate over the mounting surface such that
the wire/cable access openings are aligned while passing the
wires/cable through the case back.
***Go to "Wiring the TouchCenter" and complete wiring***
5. Secure the mounting plate to mounting surface using 4 screws
(supplied).
6. Slide TouchCenter onto mounting plate.
MOUNTING
SCREWS (4)
(TYP)
Mechanical Specifications:
Width: 8 inches (203.2mm)
Height: 5-1/2 inches (139.7mm)
Depth:1-3/8 inches (35mm)
Electrical Specifications:
Backlight OFF, Sound OFF
Backlight ON, Sound OFF
Backlight ON, Sound ON
Operating Environment:
Humidity
93% RH, no condensation
Temperature:
Operating
14˚ F to 131˚ F / -10˚ C to 55˚ C
Shipping / Storage
-40˚ F to 158˚ F / -40˚C to 70˚C
Wire Gauge:
Length
#22 gauge
150 feet
#20 gauge
240 feet
#18 gauge
350 feet
#16 gauge
550 feet
Use a UL Listed, battery-backed supply for UL installations. The battery supplies power to these keypads in case of AC power loss. The battery-backed power
U L
supply should have enough power to supply the keypads with the UL required minimum standby power time.
IMPORTANT: Keypads powered from supplies that do not have a backup battery do not function if AC power is lost. Make sure to power at least one keypad in
each partition from the control's auxiliary power output or UL Listed battery backed up power supply.
IMPORTANT: When the TouchCenter is powered from an auxiliary power supply, always apply power to the control panel first and then the TouchCenter. Failure to observe
this sequence results in improper operation of the TouchCenter and may result in an ECP Error indication.
Connect the wires to the TouchCenter terminal block as shown.
• Connect the TouchCenter in parallel with keypads and other peripheral devices using the keypad data (ECP) bus.
• If the TouchCenter is used as the primary system keypad, maximum wire run length is 150 feet.
• If more than one keypad is wired to one run, then the maximum lengths must be divided by the number of keypads on the run. (e.g., the maximum length is 75 feet if two keypads are
wired on a #22 gauge run).
Note: Unshielded 4-conductor cable is recommended for the power/data wire.
Programming the Control Panel
The TouchCenter is not fully operational unless its address in the control panel
has been enabled (set as an alpha console) AUI type device, and assigned to a
partition (where applicable).
We recommend that you use either a standard alpha keypad or the TouchCenter in
Console Emulation Mode when programming the control panel. When in the
Console Mode, the TouchCenter emulates an alpha keypad and the programming
of the panel is performed following the procedures provided in your panel's
Installation & Setup Guide.
Note: When programming your control panel, if you change the zone types for your
emergency zones you may disable the emergency icons in the TouchCenter. The
emergency icons in the TouchCenter are active for zone types 06 and 07 (Panic
icon), 08 (Medical icon), and 09 (Fire icon). Additionally, the Medical icon is also
compatible with a zone type 15 (24-Hour Medical) for panels that contain this zone
type.
The TouchCenter should not be assigned as a Master Console. If the TouchCenter
is assigned as a Master Console, partitions must be controlled from the Partition
screen or by using the Console Emulation Mode.
TouchCenter Initialization
When initially powered, the screen displays the boot sequence and the "Set ECP
Address" screen is displayed. If the system is incorporating only one TouchCenter,
leave the address set to 1 and touch Apply. The boot-up process continues until
Mounting the TouchCenter
Mounting without mounting plate:
1. Select a mounting location.
2. Detach the mounting plate by sliding downward and
discard.
3. Use the template (provided in the carton) to mark the
location of the mounting screws and the cut-out for the
TouchCenter assembly on the mounting location. Check
for level.
4. Install 4 screws (supplied) in the mounting surface
leaving screw heads 1/8" above the mounting surface.
5. Locate the case back over the mounting surface such
that the opening is aligned with the wire/cable access
opening on the mounting surface while passing the
WALL
SURFACE
wires/cable through the opening in the case back.
**Go to "Wiring the TouchCenter" and complete wiring
6. Mount TouchCenter by sliding onto the screw heads.
6 2 8
0 S
E R
IE S
C A
S E
B A
C K
M O
4 -
3/4
U N
"
CU
T-O
UT
LO
CA
TIO
N
WALL
MOUNTING
Ê 8
0 0
- 0
DR
PLATE
800
-08
0 8
ILL
831
3 1
3/1
6"
5/1
1
u Š
DI A.
Rev
HO
.A
LE
(OPTIONAL)
6280-006-V0
Wiring the TouchCenter
6280
12V, 140mA
12V, 205mA
12V, 270mA
6280 TouchCenter
WALL
SURFACE
TEMPLATE
T IN
G T
E M
P L
A T
E
DR
ILL
3/1
6"
4 PL
DI A.
AC
HO
ES
LE
S
MOUNTING
SCREWS
INSTALLED
1/8" ABOVE
SURFACE
YELLOW
(DATA FROM
CONTROL)
RED (+12VDC)
Y
BLACK (GND)
GREEN
G
(DATA TO
CONTROL)
Initial Setup
completion. If there are to be additional TouchCenter units in the system, after
enabling addresses in the control panel using an alpha-keypad, power-up each
TouchCenter one at a time, and set its address to one of the addresses you
enabled in the control panel.
Note: If the top of the screen is displaying ECP Error, the TouchCenter ECP
Address is not valid for the panel that it is connected to. To change the ECP
Address, enter the default code of "4140" to advance to the next screen.
Note: 4140 is the TouchCenter default installer code before connecting to a
control panel. Once connected to a control panel, use the panel's installer code.
Change the ECP Address on the unit, using the Up/Down arrows and then touch
apply to accept the address and reset the TouchCenter. Once communication has
been restored, then use the standard panel installer code for all installer
functions. Refer to "ECP Setup" section.
If not already set from the panel, set the current time and date. Refer to
"Time/Date Setup" section.
The TouchCenter is defaulted to arm the system in the STAY INSTANT mode
when arming the system using the NIGHT icon.
Select the arming mode to be activated when the NIGHT icon is touched on the
"Arming" screen, refer to "Night Setup" section.
* Refer to the instructions on the following pages to customize your TouchCenter.
Ê800-07600ÀpŠ
800-07600 7/11 Rev. A
Front Panel LEDs
SD/SDHC CARD Slot
ARMED (RED) LED
ON – System is armed.
OFF – System is not armed.
READY (GREEN) LED
ON – System is disarmed and ready to arm.
OFF – System is armed or disarmed but not
ready. If disarmed, faults or troubles are present.
MESSAGE (YELLOW) LED
FLASHING – The system contains new
message(s) for the User.
OFF – No new messages.
RESET BUTTON
Press to unlock keypad
The 6280 complies with the European Standard
EN50131 and is designed to prevent unauthorized use.
Mounting (European Installations) using a center securing
screw:
1. Detach case front by removing the two bottom screws. Gently pull
up using a screwdriver if necessary and pry apart. Lift off cover.
2. Mount the TouchCenter in its final location, (see "Standard
Mounting" or "Mounting without the mounting plate") install center
securing screw (supplied) and tighten to mounting surface.
3. Replace the case front and secure using the two bottom screws.
CASE
FRONT
CASE
BACK
DETACH CASE FRONT
BY REMOVING SCREWS (2)
AND LIFT UP
CONTROL
POWER FROM SUPPLEMENTARY
TERMINAL STRIP
POWER SUPPLY IF USED
AUX
AUX
DATA
DATA
SUPPLEMENTARY
IN
OUT
+12 VDC
POWER SUPPLY
P/N AD12612
BLACK
BLACK
RED
GREEN
YELLOW
Time/Date Setup
NIGHT Setup
6280-001-V0
INSTALL TAMPER
SCREW
6280-015-V0
CONTROL
TERMINAL STRIP
AUX AUX
DATA
DATA
IN
OUT
6280-014-V0
loading

Summary of Contents for Honeywell 6280

  • Page 1 User. Word List OFF – No new messages. The 6280 TouchCenter can annunciate a series of words. You must use RESET BUTTON the vocabulary list in your alarm panel instructions for actual words that Press to unlock keypad 6280-001-V0 may be annunciated;...
  • Page 2 Allows user to hear system status. card first. to convert videos for proper playback on the 2. Touch the Multi-Media icon, and then 6280. Use an Internet search engine to locate and download the VLC touch the Video icon. “Video”...
  • Page 3 COMPATIBILITY TABLE CS Setup Notes Maximum Number Minimum Software 1. From the System Setup screen, touch the When the TouchCenter cannot communicate of TouchCenters Revision Level Alarm System with the alarm panel, the message “ECP CS Setup icon. Error” is displayed, check the following: VISTA-15P •...
  • Page 4 Output Setup Notes Word List The 6280 can annunciate the words listed below. Please note that 1. From the “Home” screen, touch the The Output Setup function allows you to this listing does not increase the vocabulary available from your System Setup and Advanced Setup icon.