Fout Function (Clock Output Function); Fout Control Register; Fout Function Table - Epson RX8111CE Applications Manual

Real time clock module
Hide thumbs Also See for RX8111CE:
Table of Contents
RX8111CE
5) VCMP bit
User can monitor the status of VCMP during the period that battery is being recharged.
VCMP
Read
6) VLOW bit
User can monitor the result of VLOW (battery backup lower voltage) .
VLOW
Read

14.6. FOUT function (Clock output function)

The clock signal can be output via the FOUT pin. In case of inactive pin output becomes Hi-Z.

14.6.1. FOUT control register

Address
1Dh
FOUT pin can be terminated as wake-up timer too. When FOUT function is needed, TMPIN should be "0" and /INT pin should be
wake-up timer interrupt output.

14.6.2. FOUT function table

1) FSEL1,FSEL0 bit
FSEL1
At the time of the initial power-on, "0" is set to FSEL1, FSEL0.
Note: The effect of STOP bit to FOUT functions.
When STOP = "1", 32.768 kHz and 1024 Hz output is possible.
But 1 Hz output is disabled.
Data
Description
0
V
< V
BAT
1
V
> V
BAT
Data
Description
0
V
> V
BAT
1
V
< V
BAT
Table 42 FOUT control register
Function
Extension Register
FSEL0
0
0
0
1
1
0
1
1
Table 40 VCMP bit (VCMP)
Recharging
DD
Recharging suspended SW2:OFF
DD
Table 41 VLOW bit (VLOW)
LOW
LOW
bit 7
bit 6
bit 5
FSEL1 FSEL0
USEL
Table 43 FSEL register
Output
32.768 kHz Output
1024 Hz Output
1 Hz Output
OFF
Page − 35
bit 4
bit 3
bit 2
TE
WADA
ETS
bit 1
bit 0
TSEL1 TSEL0
ETM61E-01
Table of Contents
loading

This manual is also suitable for:

Rx8111ce aRx8111ce b

Table of Contents