  • Page 1 Hitachi NAS Platform 5000 Series Hardware Reference Release 13.9 MK-92HNAS089-00 December 2020...
  • Page 2: Legal Notices

    Materials. “Materials” mean text, data, photographs, graphics, audio, video and documents. Hitachi reserves the right to make changes to this Material at any time without notice and assumes no responsibility for its use. The Materials contain the most current information available at the time of publication.
  • Page 3: Table Of Contents

    Canada......................15 Radio Protection for Germany................15 Food and Drug Administration (FDA)..............16 Chinese Compulsory Statement................ 16 Chinese RoHS Compliance Statement..............17 Chapter 4: Hitachi NAS Platform server components....... 18 System components..................19 Server components....................20 Server specifications..................21 Ventilation......................23 Server front panel....................23 LED status indicators..................25...
  • Page 4 MAC ID and license keys................51 Previous backups..................51 Upgrades......................52 Replacing a server.....................52 Obtaining backups, diagnostics, firmware levels, and license keys..... 52 Shutting down a server that you are replacing ..........54 Contents Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 5 Configuring the replacement servers............54 Finalizing and verifying the replacement server configuration..... 56 Chapter 8: Accessing the server CLI..........60 Chapter 9: Parts list for NAS Platform Series 5000......61 Contents Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 6: Preface

    Preface This guide provides an overview of the Hitachi NAS Platform and the Hitachi Unified Storage File Module hardware. This guide explains how to install and configure the hardware and software for the 5200 and 5300 server models, and how to replace faulty components.
  • Page 7: Chapter 1: About This Guide

    Ellipses indicate that a preceding element can be repeated. GUI element This font denotes the names of graphical user interface (GUI) elements such as windows, screens, dialog boxes, menus, toolbars, icons, buttons, boxes, fields, and lists. Chapter 1: About this guide Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 8 Los siguientes iconos se utilizan a lo largo de la guía con fines de seguridad. Se le aconseja leer, y entender en su totalidad, cualquier procedimiento marcado con estos iconos antes de proceder. Chapter 1: About this guide Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 9 We raden u aan even halt te houden bij de sectie die door dit woord wordt gemarkeerd, tot u de procedure volledig begrijpt. WAARSCHUWING: Een waarschuwing wijst op een mogelijk gevaar voor de persoonlijke veiligheid. Chapter 1: About this guide Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 10 FÖRSIKT: “Försikt” anger vad som kan leda till data eller utrustningsskador. Fortsätt inte till nästa avsnitt innan du förstår det steg som har markerats med detta meddelande. VARNING: “Varning” anger vad som kan leda till personskador. Chapter 1: About this guide Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 11: Chapter 2: Safety Information

    Fill all expansion cabinets including all storage enclosures from the bottom ■ to the top. Do not remove more than one unit from the rack at a time. ■ Chapter 2: Safety information Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 12: Electrical Precautions

    These cords are for use with a power distribution unit (PDU), which is mounted inside the 19-inch rack. If you require longer cables, contact your Hitachi representative. Provide a safe electrical ground connection to the power cord. Check the grounding of ■...
  • Page 13: Chapter 3: Mandatory Regulations

    FCC/CFR 47:Part 15 ■ Canadian Standard ICES-003:Issue 6 ■ AS/NZS CISPR 22 ■ EN 61000-3-2:2019 ■ EN 61000-3-3:2013 inc A1:2019 ■ EN 55035:2017 ■ NRRA Notice 2018-17 ■ VCCI-CISPR32:2016 ■ Chapter 3: Mandatory regulations Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 14: Federal Communications Commission (Fcc)

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. The device can not cause harmful interference. 2. The device must accept any interference received, including interference that might cause undesired operation. Chapter 3: Mandatory regulations Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 15: European Union (Eu) Statement

    Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Radio Protection for Germany Dieses Gerät erfüllt die Bedingungen der EN 55022 Klasse A. Chapter 3: Mandatory regulations Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 16: Food And Drug Administration (Fda)

    The product complies with FDA 21 CFR 1040.10 and 1040.11 regulations, which govern the safe use of lasers. Chinese Compulsory Statement China Compulsory Certificate Statement 声明此为 A 为为品,在生活为境中,为为品可能会造成无为为干为。在为种情况下,可能需要 用为为其干为采取切为可行的措施。 Chapter 3: Mandatory regulations Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 17: Chinese Rohs Compliance Statement

    Chinese RoHS Compliance Statement Chinese RoHS Compliance Statement Note: The Hard Disk Drive is a solid state disk (SSD) device. Figure 1 Chinese RoHS Compliance Statement Chapter 3: Mandatory regulations Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 18: Chapter 4: Hitachi Nas Platform Server Components

    Chapter 4: Hitachi NAS Platform server components A Hitachi Unified Storage File Module system can contain several servers that operate as a cluster. Clusters of more than two servers include two 10 Gbps Ethernet switches. Hitachi Vantara only requires two switches for redundancy.
  • Page 19: System Components

    In clustered systems, an external SMU provides the management functionality. In some cases, multiple SMUs are advisable. Storage A Hitachi NAS Platform system or a Hitachi Unified Storage File systems Module system can control several storage enclosures. The maximum number of storage enclosures in a rack depends on the model of storage enclosures being installed.
  • Page 20: Server Components

    Server components Component Description Hitachi Vantara requires dual 10 GbE switches for redundancy. In a dual-switch configuration, if one switch fails, the cluster nodes remain connected through the second switch. Server components The NAS Platform Series 5000 server comes in two models: 5200 and 5300.
  • Page 21: Server Specifications

    3U, 5.2 in. (132mm)/ 17.3 in. (440mm)/28.6 in. (725mm) Weight Weight 51 lbs. (23kg) Compliance RoHS 6 China RoHS Compliant EU RoHS Compliant Safety EU: EN62368-1: 2nd edition Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 22 Non-operational shock: 3g 11ms, half sine ■ Packaged transport specification: Drops from 356mm and 508mm as per ASTM D5276 ■ Vibration at up to 0.53 Grms as per ASTM D4728 ■ Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 23: Ventilation

    Once the bezel is removed, the front-facing components on the server chassis are visible. Figure 3 Server model 5200 / 5300 front panel components (bezel removed) Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 24 Disk B status LED Disk A status LED Fan 1 Fan 2 Power status LED Server status LED Fan 1 status LED Fan 2 status LED Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 25: Led Status Indicators

    Table 4 Power status LED (green) LEDs Meaning Green Normal operational mode of an active cluster node. Slow flash The system has been shut down. (once every three seconds) Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 26 (This LED will be on if the corresponding fan has been removed.) Replace the fan as soon as possible. Normal operation. The following table describes the O/S disk activity and status LEDs: Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 27: O/S Drives

    Hitachi Vantara Customer Support. The O/S drive A and B status and activity status LEDs of the 5200 and 5300 server models are shown as follows: Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 28: Fans

    RAID configuration has been degraded. Fans The server features dual hot-swappable fan assemblies. The fans provide for front-to- back airflow to be consistent with other storage system components. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 29 Two fan status LEDs provide fan status information. These LEDs are located behind the bezel on the right side of the chassis. Item Description Fan 1 (left) Fan 2 (right) Fan 1 status LED Fan 2 status LED Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 30: Server Rear Panel

    ■ the corresponding cluster server ports (left port to left port and right port to right port). N-way configuration: Connect to the ■ 10 GbE switch. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 31 ETH1 1000baseT Ethernet Management port. Connect to the internal Ethernet switch of the rack. Video port Video management interface port. (Reserved for Customer Service Engineer access only.) Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 32: Rear Panel Server Led And Button Locations

    NVRAM is currently being protected by the super capacitor’s backup power. The way an LED flashes provides further information about what is currently occurring. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 33 O/S disk drive A status LED Power status LED Server status LED Fan 1 status LED Fan 2 status LED The following table describes the various power status LEDs. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 34: 10 Gigabit Cluster Ethernet Interconnect Ports

    (SFP+) optical connector. Do not use the 10 GbE cluster interconnect ports to connect to the customer data network (also known as the public data network). Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 35: Power Button (Pwr)

    Under normal circumstances, the power button is rarely used. However, the power button can be used to restore power to the system when the server is in a standby power state. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 36: Reset Button (Rst)

    Status LED is not lit, press the PWR button to restore power to the system. Open a case with Hitachi Vantara Support Connect to get the problem resolved. Note: Do not use the power button during normal operation of the server.
  • Page 37: 10 Gigabit Ethernet Customer Data Network Ports

    HBA fault(LEDs Host Bus Adapter faulted flash in sequence) 10 gigabit ethernet customer data network ports See the Network Administration Guide for more information on creating aggregations. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 38: Ethernet Management Ports 0 And 1

    The green LED indicates activity, while the other link LED may be green, amber, or off to indicate the speed of the connection. Refer to the following tables for more information. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 39: Serial Port

    LED on the right indicates activity, while the green LED on the left indicates the speed of the connection. Refer to the following table for more information. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 40: Management Interfaces

    The serial port is not intended as a permanent management connection. This port should not be used as the primary Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 41: 10/100/1000 Ethernet Management Ports

    LEDs; one on the top left and the second on the top right of the port. Ethernet cables CAT6 cables that fully comply with the CAT6 SF/UTP standard for the 1000Base-T GE Ethernet network ports are required. Chapter 4: Hitachi NAS Platform server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 42: Chapter 5: Replacing Server Components

    Removing and replacing the front bezel To access some server components or field replaceable units (FRUs), you must first remove the front bezel. Replace the bezel after the part replacement is complete. Chapter 5: Replacing server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 43: Replacing A Fan

    6. Secure the fan assembly in position by tightening the thumbscrews (turning them clockwise). 7. Replace the front bezel. Chapter 5: Replacing server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 44: Recovering Or Replacing A Drive

    Important: Do not attempt to replace or recover a drive without the assistance of Hitachi Vantara Customer Support. For the latest procedure, please refer to Support Connect article How_to_Replace_a_Chassis_Hard_Disk_in_an_HNAS_Gateway_Node (which is only visible to service partners and employees).
  • Page 45: Replacing A Power Supply

    The PSU should start as soon as the power connection is made. If the PSU does not start immediately, make sure the main power circuit is live and that the other end of the power cable is connected to a live outlet. Chapter 5: Replacing server components Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 46: Chapter 6: Rebooting, Shutting Down, And Powering Off

    Note: Clicking reboot stops all file serving EVSs on the selected node or all cluster nodes, then reboots the node/nodes. Rebooting may take up to five minutes. Chapter 6: Rebooting, shutting down, and powering off Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 47: Restarting An Unresponsive Server

    4. If you are still unable to get to the server OS, perform the following steps: a. Ensure that the NAS CLI is booting successfully. Chapter 6: Rebooting, shutting down, and powering off Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 48: Powering Down The Server

    3. Power down the server by removing the power cables from the PSU modules. Powering on the server or cluster To start/power on a server or cluster: Chapter 6: Rebooting, shutting down, and powering off Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 49: Recovering From Power Stand-By

    You can restore the server to its normal power state by either of the following methods: Press the PWR button. ■ Remove the power cables from both PSUs, wait for 10 seconds, then reconnect the ■ cables to the PSUs. Chapter 6: Rebooting, shutting down, and powering off Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 50: Chapter 7: Server Replacement Procedures

    SSH client settings: 115,200 b/s ■ 8 data bits ■ 1 stop bit ■ No parity ■ No flow control ■ VT100 emulation ■ Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 51: Swapping Components

    As part of the field replacement process, Hitachi Vantara recommends that you obtain temporary keys to enable quick delivery and implementation. However, any temporary keys must eventually be replaced with a permanent key.
  • Page 52: Upgrades

    4. For a node in a cluster, migrate the EVSs to an alternate node. 5. Navigate to Home > Status & Monitoring > Download Diagnostics. 6. Click download to retrieve the diagnostic test results. Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 53 9. Record the following information: IP addresses for Ethernet ports 0 and 1 ■ Gateway ■ Domain name ■ Host name ■ Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 54: Shutting Down A Server That You Are Replacing

    For a single NAS server, when you run the nas-preconfig script, it reconfigures the server to the previous settings. This step allows the SMU to recognize the server as the same and to be managed. Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 55 11. Click Yes to proceed past the security alert, and log in as admin. 12. Verify and, if necessary, convert the new server to the model profile required. This step requires a separate process, training, and license keys. Contact Hitachi Vantara if the incorrect model arrives for replacement.
  • Page 56: Finalizing And Verifying The Replacement Server Configuration

    6. If the server does not recognize the system drives, enter fc-link-reset to reset the fiber paths. 7. Enter the sdpath command to display the path to the devices (system drives) and the port and storage port that are used. Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 57 12. Enter the span-assign-to-cluster span_label command to assign all the spans to the new server. 13. If EVS mapping or balancing is required, select the EVS to migrate, assign it to the preferred node, then click migrate. Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 58 15. Select the node from the Preferred Cluster Node list, then click apply. 16. Reconfigure any required tape backup application security. 17. Navigate to Home > Status & Monitoring > Event Logs, and click Clear Event Logs. Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 59 Features such as replication and data migration must all be confirmed as working, and all file systems and storage pools must be online. Chapter 7: Server replacement procedures Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 60: Chapter 8: Accessing The Server Cli

    Chapter 8: Accessing the server CLI Performing certain tasks require that you access the server through the command line interface (CLI). Refer to the System Access Guide for more information. Chapter 8: Accessing the server CLI Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 61: Chapter 9: Parts List For Nas Platform Series 5000

    Brocade VDX 6740 ■ 10GbE Switch, 16 ports ■ SFP+, AC, "F" for front ■ side or "R" for rear side exhaust Exhaust AF ■ Chapter 9: Parts list for NAS Platform Series 5000 Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 62 1310 nm. single- 6 x 10GbE network ports ■ ■ mode 4 x cluster ports ■ 3.3v ■ Not supported in: 4 x Fibre Channel ports Chapter 9: Parts list for NAS Platform Series 5000 Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 63 10GbE Not supported in 4 x cluster ■ network ports, 5 ports meters Not supported in 4 x Fibre ■ Channel ports Chapter 9: Parts list for NAS Platform Series 5000 Hitachi NAS Platform Series 5000 Hardware Reference...
  • Page 64 Hitachi Vantara Corporate Headquarters Contact Information 2535 Augustine Drive USA: 1-800-446-0744 Santa Clara, CA 95054 USA Global: 1-858-547-4526 HitachiVantara.com | community.HitachiVantara.com HitachiVantara.com/contact...