6.3 V/f Control

With V/f control, the user must set the Inverter input voltage, motor selection, rated current, and V/f pattern.
6.3.1 Setting the Motor Constants: E1-01, E1-02, E2-01

Inverter Input Voltage: E1-01

J
Set the Inverter input voltage (E1-01) to match the power supply voltage.
D
User
User
Constant
Number
E1-01
The voltage settings shown in parentheses are for 400 V class Inverters.
D
This setting is used as a reference value for functions such as the protection functions.
D
Motor Selection and Rated Current: E1-02, E2-01
J

Motor Selection (Motor Overheating Protection: E1-02

Set the type of motor being used. This setting is a reference for overheating protection functions.
D
User
User
Constant
Number
E1-02
Settings
D
Setting
Motor Rated Current (Electronic Thermal Reference Current): E2-01
Set the rated current (A) shown on the motor nameplate.
D
User
User
Constant
Number
E2-01
* 1. The setting range is 10) to 200% of the Inverter rated output current.
* 2. The factory setting depends upon the Inverter capacity. Refer to pages 8 - 47 and 8 - 49.
Change
during
during
Name
Opera-
tion
Input voltage set-
×
ting
Change
during
during
Name
Opera-
tion
Motor selection (mo-
tor overheating
×
protection)
0
Standard motor (general-purpose motor)
1
Special motor (inverter-exclusive motor)
2
Special motor (vector-exclusive motor)
Change
during
during
Name
Opera-
tion
Motor rated current
(electronic thermal
×
reference current)
6 - 21
g
Setting
Setting
Factory
Factory
Unit
Range
Setting
155 to 255
200
VAC
(310 to 510)
(400)
g
Setting
Setting
Unit Factory
Factory
Range
Setting
0 to 2
0
Function
g
Setting
Setting
Unit Factory
Factory
Range
Setting
(10% to 200%
*2
of rated
A
current)
*1
6.3 V/f Control
Valid Access Levels
Open
V/f
V/f with
Flux
Loop
Control
PG
Vector
Vector
Q
Q
Q
Q
Valid Access Levels
Open
V/f
V/f with
Flux
Loop
Control
PG
Vector
Vector
Q
Q
Q
Q
Valid Access Levels
Open
V/f
V/f with
Flux
Loop
Control
PG
Vector
Vector
Q
Q
Q
Q
6

Hide quick links:

Table of Contents
loading

Table of Contents