Page 1
DP50749-01 Panel: Self Test Panel is capable of generating internal patterns without the Main Signal Board attached. (rotating: white / red / green / blue / and various other patterns) This test eliminates Main Signal Board from circuit and confirms if panel itself is operating properly.
Page 2
LG PANEL FOR DP50749/ J4FF Jumper between these two points Logic Board For Panel Self Test to Run: 1) Must unplug LVDS Cable between Main Bd. & Logic Bd.. 2) Must unplug cable between Pwr Bd. (P813) and Main Bd. (K8P & K8B) 3) Short the above two points on the Logic Bd.
Page 3
1) Connect Y-DRV and Y-SUS B/D 2) Insert and push the retainer until click sound is heard. [Y-DRV TOP] Retainer [Y-SUS] PDP module Model: PDP50G2T0000 DP50749-01 (J4FF) P109 4 RETAINERS PER TV 3. Cause P107 : insufficient connection between Y-DRV B/D and Y-SUS B/D P208 4.
Page 4
Service Information is given in this manual. For detailed Service Information, refer to the Original Service Manual and Notices for Chassis No. P50749-00 used in Model DP50749 (SM780163). SERVICING SHOULD BE PERFORMED BY ONLY TRAINED AND QUALIFIED SERVICE PERSONNEL.