ZEN FLOAT TENT Assembly Instructions Manual

Hide thumbs Also See for FLOAT TENT:

Quick Links

FLOAT TENT ​
T M
ASSEMBLY INSTRUCTIONS
VIDEO INSTRUCTIONS: zenfloatco.com/setup
Version 2.3, updated 09/31/2020.
For help with watercare maintenance go to, Zenfloatco.com/water-care/
1
Table of Contents
loading

Summary of Contents for ZEN FLOAT TENT

  • Page 1 FLOAT TENT ​ ASSEMBLY INSTRUCTIONS VIDEO INSTRUCTIONS: zenfloatco.com/setup Version 2.3, updated 09/31/2020. For help with watercare maintenance go to, Zenfloatco.com/water-care/...
  • Page 2: Important Safety Instructions & Warnings

    IMPORTANT SAFETY INSTRUCTIONS & WARNINGS READ AND FOLLOW ALL INSTRUCTIONS. When using this electrical equipment, basic safety precautions should always be followed, including the following: LOAD BEARING CAPACITY & WATER THE FLOAT TANK IS INTENDED FOR USE BY ONE PERSON AT A TIME.
  • Page 3: Fire Hazard

    ANY FLAME OR OTHER HEAT SOURCE. DRUGS AND ALCOHOL USE DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING USE OF THE FLOAT TENT. THE USE OF DRUGS OR ALCOHOL MAY INCREASE THE RISK OF INJURY, UNCONSCIOUSNESS, AND POSSIBLE DROWNING.
  • Page 4: Property Damage

    ADDITIVES AND SALT INGESTION DO NOT ADD ADDITIVES (SUCH AS BUBBLE BATH AND BATH SALTS) TO THE WATER IN THE FLOAT TENT, OTHER THAN EPSOM SALT AS DIRECTED. DO NOT INGEST THE WATER IN THE FLOAT TENT. PROPERTY DAMAGE DO NOT OVERFILL THE FLOAT TENT. NEVER LEAVE THE FLOAT TENT UNATTENDED WHEN FILLING WITH WATER.
  • Page 5: Additional Warnings

    ★ CAUTION: To avoid damage to the Water Pump it must never be operated unless the Tent is filled with water. ★ NOTE: Please examine equipment before use. Notify Zen at the customer service address listed on this manual for any damaged or missing parts at the time of purchase.
  • Page 6: Package Contents

    PACKAGE CONTENTS 6 x SHORT POLES - 14” 8 x MEDIUM POLES - 34” 6 x LONG POLES - 42” 2 x T-CONNECTOR 3 x METAL DOOR POLES 5 x PLASTIC DOOR POLES...
  • Page 7 1 x TOP CONNECTOR 2 x RIGHT CORNER 2 x LEFT CONNECTOR *Pre-assembled w/ Top Connector Nut & Bolt 1 x VINYL TENT COVER 1 x VINYL TUB 1 x DRIP MAT 2 x HEATING PADS 4 x VENT CAPS 1 x TEMP CONTROLLER *Pre-plugged w/ Grounding Probe...
  • Page 8 1 x WATER PUMP & 1 x FILTER BAG 2 x FILTER HOSE, 1 x T & 1 x UV WATER FILTER *Additionals incl. w/ Float Ready 1 x 90 DEGREE Package *Pre-connected FITTINGS, & 1 x PUMP MANIFOLD 1 x STRUCTURE STRAP 1 x WALL GFCI 1 x GROUND PROBE *120V models only...
  • Page 9 ★ Choose a preferred location that will stay between 70° and 90° Fahrenheit (21° to 32° Celsius). ★ Allow at least 1 ft (30 cm) of space between the Float Tent and the room’s walls to allow for maintenance and cleaning.
  • Page 10 2. ASSEMBLE WATER TUB To verify there were no punctures in transit, move the tub to an outdoor area and fill up to ten inches. If you have any leaks contact us immediately. NOTE: ​ P oles are threaded through sleeves on the water tub. NOTE: ​...
  • Page 11 3. ASSEMBLE PYRAMID FRAME Assemble the frame onto the existing tub, then make the final connection at the tip of the pyramid last.
  • Page 12 4. PLACE LINER AND TANK IN PLACE IMPORTANT VERIFY THE PADS ARE THE CORRECT SIDE UP! ★ They will have markings on each pad to verify which side is up. ★ Plug in the pads temporarily to verify they werenít damaged in transit. The pads will heat almost too hot to touch.
  • Page 13 NOTE: ​ H eating Pads will overlap in the center. With heating pads properly placed, cover with waterproof liner and place the tub directly over pads. The liner should stick out evenly on three sides, but there should be excess on the side where the tent door will face. With the liner in place, the tub will sit exactly over them.
  • Page 14 5. INSTALL FILTRATION SYSTEM A. Pump Manifold D. T Fitting B. Water Pump & UV Water Filter E. 90 Degree Fitting C. Filter Bag (at front of tank) 1. Start by setting the Water Pump and UV Water Filter (B) in place. 2.
  • Page 15 Add 100 lbs (45 kg) of salt at a time, mixing in fully as you go. NOTE:​ If you bought your salt from zen float co., we provide 800 lbs (363 kg) of salt per pallet and you will need all of it for the first fill of your tent.
  • Page 16 4. Once 800 lbs (363 Kg) of salt is added, fill until the water level reaches 10 inches (25.5 cm).
  • Page 17 7. PLUG - IN AND VERIFY SAFETY Plug the Temperature Controller, the Water Pump and the UV Pump into the GFCI outlet. For safety, the tank water should be electrically grounded due to a possible induced current from the heaters. Make sure the Grounding Probe is plugged in and submerged at all times.
  • Page 18 8. TURN ON AND VERIFY SETTINGS 1. Plug the two heating pads into the Temperature Controller. 2. Plug the UV Filter in. The first thing you will notice is a slight glow from the UV filter. The Temperature will now display a temperature detected by the attached temperature sensor. 3.
  • Page 19 9. INSTALL TENT COVER Float Tent Cover will have a tight fit. Work each corner one at a time sliding them down a few inches each time around.
  • Page 20 10. INSTALL TENT DOOR Door poles go in sleeves located around the perimeter of both the tent wall and tent door flap. Each pole will have a number on it. Insert poles in their corresponding pole sleeves as illustrated below. TIP:​...
  • Page 21 11. INSTALL AIR VENTS 1. Insert vent stem through vent holes on the back of the Float Tent and snap together with the other half of the vent on the other side. 2. Tuck in three tabs to start and use a finger to tuck the fourth in.
  • Page 22 12. PLACE CONDENSATION LINER From the inside of the Float Tent, free the condensation liner out from the cover and tank walls. Allow the liner to hang free so any condensation dripping down the tent walls will drip down the liner and back into the tank.
  • Page 23 SAVE THESE INSTRUCTIONS Zen Float Co. 5947 South 350 West Murray, UT 84107 Tel: 801.871.5140 Email: [email protected]...

Table of Contents