Standard Door Installation
(Pull Side) - Fig 1
Step by Step Installation Guide
Use the appropriate template for your installation and place
the template on the door and frame. Pilot drill all fixing holes
as per the template.
Hinge knuckle
is visible
1.
Position the door closer with the power adjustment valve
facing away from the hinge side of the door. Secure the
door closer using the screws provided into the pre-drilled
pilot positioning holes.
2.
Attach the armset to the pivot on the door closer body and
secure using the washer screw.
3.
Tension the door closer arm and adjust the arm length
accordingly. Secure the arm set shoe to the door or frame
depending on installation, then tighten the arm set screw.
4.
Apply the dust cap to the unused pivot.
5.
Make necessary adjustments to closing, latching,
back check, delayed action and door closer power valves
as required (refer to valve adjustment instructions).
NB after the first month of operation the adjusment valves
may require minor adjustment.
65˚
Closing Speed
Latching Speed
15˚
Frame Fix Installation
(Push Side) - Fig 61
Hinge knuckle
is not visible
Valve Adujustment Instruction Guide
Closing Speed: Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Latching Speed: Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Delayed Action: Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Left hand fitting only, use reverse for right hand fitting.
Standard Door Installation - View from above
Delayed Action & Back Check
Frame Fix Installation - View from below
Back Check: Adjust valve by quarter turns
anti-clockwise to increase speed or clockwise to
reduce speed.
Power Adjustment: Adjust valve by quarter turns
anti-clockwise to reduce power or clockwise to
increase power.
CAUTION
Adjusting valves more than 2 full turns
anti-clockwise from factory settings will
result in oil leakage damaging the door closer.
Acceleration
Deceleration
Failure to comply with this will void the warranty.
Pull Side - Fig 1
Washer Screw
Armset Shoe
Hinge Knuckle
Threaded
Arm (bolt)
Adjustment Valves
Dust Cap
Nut
Door Closer Body
Armset
Preload
Armset Pivot Screw
Washer Screw
Push Side - Fig 61
Armset Shoe
Hinge Knuckle
Threaded
Arm (bolt)
Adjustment Valves
Nut
Door Closer Body
Armset
Preload
Armset Pivot Screw
Door Closer Installation
Armset Shoe
Power Adjustment Valve - 5
Power Adjustment Valve - 5
Dust Cap
Armset Shoe
SPRING POWER-ADJUSTMENT CHART FOR DOOR SELECTIONS
(Up to 1200mm Door Height)
D o o r C lo s e r S ize
A pplic a ble do o r
( 2 - 4 )
we ight ( k g)
EN2
30-45
EN3
45-65
EN4
65-80
XL8800 Series
4
3 8
1 1 3
C
2
b
30/60
EN1154:1996 / A1:2002 / AC:2006
EN1634-1:2008 FD30/FD60 Timber Doors
Fig 1 Application Only
Door Closer Body
Door Closer Body
SPRING POWER ADJUSTING VALVE
Controls opening and closing force
Factory setting size 3
Adjust according to table to change closer size when needed
N o . o f t urns
A pplic a ble m a x.
F ro m f a c t o ry s e t
do o r widt h ( m m )
po s it io n
900
-5
1000
0
1200
5