15.3.5 Symptom: The pump is blocked

15.3.6 Symptom: The pump is making noise (cavitation)

EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Possible cause
Various malfunctions.
(a)
We recommend to purge air with the air purge function of the unit (to be performed by
the installer). If you purge air from the heat emitters or collectors, mind the following:
WARNING
Air purging heat emitters or collectors. Before you purge air from heat emitters or
collectors, check if
If not, you can purge air immediately.
If yes, make sure that the room where you want to purge air is sufficiently
ventilated. Reason: Refrigerant might leak into the water circuit, and
subsequently into the room when you purge air from the heat emitters or
collectors.
Possible causes
If the unit has been powered off for a
long time, lime might block the rotor of
the pump.
(a)
If you cannot deblock the rotor of the pump with this method, you will need to
disassemble the pump and turn the rotor by hand.
Possible causes
There is air in the system
Check if
home screen of the user interface. See
"To display the help text in case of a
malfunction" [
information about the malfunction.
or
is displayed on the home screen of the user interface.
Remove the screw of the stator housing
and use a screwdriver to turn back and
forth the ceramic shaft of the rotor until
the rotor is deblocked.
Note: Do NOT use excessive force.
1
3
2
Purge air manually (see
manual air
automatic air purge function (see
perform an automatic air
4
purge" [
 225]).
15
Troubleshooting
|
Corrective action
or
is displayed on the
4
 241] for more
Corrective action
(a)
2
Corrective action
"To perform a
4
purge" [
 224]) or use the
"To
Installer reference guide
237