VENTILCONVETTORE PER INSTALLAZIONE CANALIZZATA, ORIZZONTALE E VERTICALE - Manuale installazione FAN COIL FOR HORIZONTAL AND VERTICAL DUCTED INSTALLATION ET VERTICALE GEBLÄSEKONVEKTOR FÜR KANAL-, HORIZONTAL- UND VERTIKALEINBAU FAN COIL PARA INSTALACIÓN CANALIZADA, HORIZONTAL Y VERTICAL - Manual de instalación VES030 VES130 VES230 VES330 VES040...
Manufactured with superior quality materials, in strict compliance with safety standards, the VES is easy and durable in use. The VES fan coil series is designed to be integrated into the VMF system. VMF (Variable Multi Flow) is the system capable of controlling in an intelligent way a complete...
IMPORTANT INFORMATION AND MAINTENANCE WARNING: The fan coil unit is efficiency. and creaks inside the unit, due to connected to the power supply Visual inspection of the state of the the thermal expansion of the various network and the hydraulic circuit. fan coil unit for every maintenance components (plastic and metallic), but Any intervention by personnel not...
VES 340 Coil * The VES units of sizes 0 - 1 - 2 - 3 can be used in 4 pipe installations if they are supplied with the heating coil accessory. Configuration fields By suitably combining the numerous options available it is possible to configure each model in such a way as to meet the most par- ticular of system requirements.
6 Holes for heat exchanger coil 13 Condensate drain tray 20 Right side (load bearing) 7 Hydraulic connections (water inlet) 14 Electric motor 21 Discharge air flange VES 030 VES 040 VES 130 VES 140 VES 230 VES 240 14 15...
Manufactured from any type of air ducting. - Control of the VES unit in a complex renewable materials and can be vacuum The discharge opening includes a network of up to 64 zones with 6 fan cleaned.
OPERATING LIMITS Maximum water inlet temperature °C Maximum recommended water inlet temperature °C Maximum operating pressure (800 kPa) Minimum water flow rate (Main coil) Maximum water flow rate (Main coil) 1500 1500 1500 1500 1500 1500 3000 4000 Minimum water flow rate (Heating only coil) Maximum water flow rate (Heating only coil) 1000 Ambient temperature limits (Ta)
HYDRAULIC CONNECTIONS - Carry out the hydraulic connections. WARNING: Always use a spanner with counter-spanner to connect the piping. The positions, type and diameters of the hydraulic connections are shown in the dimensional data. It is recommended to properly insulate the water piping to avoid condensate drips during cooling operation.
The electrical power cable must be of the can support the motor electrical load, H05V-K or N07 V-K type with 300/500V SPEED SELECTION: VES 030 - 040 - 130 - 140 - 230 - 330 VES 0 - 1 - 2 Velocità...
VES 3 Velocità - Speed - Vitesse- Geschwindigkeit-Velocidad Collegamento Motore - Connection to Motor - Connexion à moteur- Verbindung zum Motor - Conexión a Motor STANDARD High High High High High ROTATING THE COIL If the hydraulic connections require the...
Page 12
SCHEMI ELETTRICI • WIRING DIAGRAMS • SCHEMAS ELECTRIQUES • SCHALTPLÄNE • ESQUEMAS ELÉCTRICOS PXAE SIT3 + SIT5 Gli schemi elettrici sono soggetti ad un continuo aggiornamento, è obbligatorio quindi fare riferimento a quelli a bordo macchina. A l l w i r i n g d i a g r a m s a r e c o n s t a n t l y...