ESCALIB
Site spiral Stair Tower with side exit
loading

Summary of Contents for Honeywell COMBISAFE ESCALIB

  • Page 1 ESCALIB Site spiral Stair Tower with side exit...
  • Page 2: Main Components

    ESCALIB: SPIRAL STAIR TOWER WITH SIDE EXIT MAIN COMPONENTS: “T ” opmosT module (= module + barrier gate). Description Code Weight (kg) Foldaway erection Base CT5000 guardrail. Module CT5001 Barrier gate CT5002 Swivel guardrail swings out of the way for access at the required level.
  • Page 3: Configuration Of The Module

    CONFIGURATION OF THE MODULE The Module: All the module’s faces are secured by swivel guardrails. The triangular steps reaching into the corners A sticker on the modules and (0.51 x 1.00 m) act as bases indicates the orientation landings for resting and of the stair tower depending on the height required and gives allowing users to pass.
  • Page 4 USE OF THE ERECTION GUARDRAIL Erection guardrail in closed position: Gravity keeps the erection guardrail horizontal. It thereby enables safe slinging and safe fitting or removal of a module or barrier gate. WARNING: The erection guardrail must not be used as a substitute for the barrier gate. WARNING: During transport, reset the erection guardrail horizontally to keep to a road legal height.
  • Page 5 ASSEMBLING AND DISMANTLING Example of an Escalib with 3 modules. WARNING: Check that the ground on which the staircase Escalib is to be erected is able to withstand the load. WARNING: Comply with the general rules for handling and stability. nTermedIaTe modules REQUIREMENTS: >...
  • Page 6 WARNING: The erection guardrail must not be used as a substitute for the barrier gate. “T ” opmosT module 7 - With slings attached to the 2 6 - Fitting lifting rings, the topmost module and bolting is fitted. the barrier gate with M16x100 screw: the Bolt the 4 uprights together using erection guardrail is positioned...
  • Page 7 ASSEMBLING AND DISMANTLING FROM SCAFFOLDS Example of an Escalib with 3 modules. WARNING: Check that the ground on which the staircase Escalib is to be erected is able to withstand the load. WARNING: Comply with the general rules for handling and stability. 1 - The base must be oriented ac- 2 - Fitting and 3 - Access inside...
  • Page 8 WARNING: The erection guardrail must not be used as a substitute for the barrier gate. REQUIREMENTS: > Remove the anchorages as the Escalib is beeing dismantled. > Dismantle in the reverse order of assembly. 6 - With the sling still tied, fit the 7 - At the access modules to the base with M24 levels, the guardrails...
  • Page 9: Lifting And Moving

    LIFTING AND MOVING (No more than 8 modules stacked) WARNING: Check that the ground on which the staircase Escalib is to be erected is able to withstand the load. WARNING: Comply with the general rules for handling and stability. REQUIREMENTS: >...
  • Page 10 CONFIGURATION OF THE STAIRS Dimensions: Barrier gate Number of Wall Height of floor slab Height modules face serviced (m) 20 m 19.7 to 20.1 2.52 m 19.0 to 19.7 max. floor 19 m module. slab at 18.4 to 19.0 18 m 17.8 to 18.4 17.2 to 17.6...
  • Page 11 CONFIGURATION OF THE STAIRS Configuration of a Escalib : Example of Escalib with 2 modules: The last 4 steps are only accessible when the upper module is fitted. With 2 modules, the height serviced is limited to 5 m. 5.2 to 5.8 4.6 to 5.0 5.0 to 5.2 max.
  • Page 12 ANCHORAGE To make it easier to size the anchor points and ground bearing for the Escalib, the ground load calculations and the forces at the anchor points are given for the various configurations. If the anchors used cannot withstand Assumptions: the load calculated, increase the module 8 I - Wind action as in EN 1991-1-4:...
  • Page 13 Example: An 8-module Escalib located in Paris is subject to a peak wind pressure q p of 54 daN/m², corresponding to a wind speed of 107 km/h. In configuration I, the Escalib is anchored every 3 modules. Each anchors must withstand the following stresses: - shearing : V = 300 daN, - pullout : T = 200 daN.
  • Page 14 INDIVIDUAL CASE EXAMPLES These examples are for illustration purpose only. Contact the technical support for details Suspended: Roofer access: The Escalib can be suspended. When the Escalib cannot be Cantilevered out on H-beams, anchored to the facade, it can be the modules are assembled then steadied by push-pull props and positioned by crane to quickly...
  • Page 15: Spare Parts

    SPARE PARTS Spare parts for maintenance: MODULE ASSEMBLY GUARD RAILS Description Code Weight (kg) Description Code Weight (kg) M24x35 grade 8.8 hex head screw CT50015 0.27 + washer 1 Straight guardrail CT50005 Captive nut + pin CT50016 0.15 2 Curved guardrail CT50006 3 Guardrail with captive nut plate for CT50007...
  • Page 16 TRANSPORT Transport: For transport, Escalib must be loaded as illustrated in the figure. They must be firmly strapped in place to avoid any risk of becoming dislodged during transport. Each Escalib module is placed upright (1.68 x 1.68 m overall size). The bases can be placed on their side, alongside the modules, if necessary.