Unical HP_OWER ONE 70R User's And Installer's Manual

Unical HP_OWER ONE 70R User's And Installer's Manual

Hide thumbs Also See for HP_OWER ONE 70R:
Table of Contents
ONE
70R – 90R – 120R – 140R – 160RT – 180RT
70RK – 90RK – 120RK – 140RK – 160RTK – 180RTK
User's and Installer's ManUal
Table of Contents
loading

Summary of Contents for Unical HP_OWER ONE 70R

  • Page 1 70R – 90R – 120R – 140R – 160RT – 180RT 70RK – 90RK – 120RK – 140RK – 160RTK – 180RTK User’s and Installer’s ManUal...
  • Page 3: Table Of Contents

    6.4.7 HYDRAULIC CIRCUIT ............................... 15 REFRIGERANT DIAGRAM HP_OWER ONE 70R – 70RK - 90R – 90RK ............... 16 REFRIGERANT DIAGRAM HP_OWER ONE 120R – 120RK ..................17 REFRIGERANT DIAGRAM HP_OWER ONE 140R - 140RK - 160RT – 160RTK - 180RT - 180RTK ......17 ELECTRICAL CONNECTIONS ............................
  • Page 4 ACCES ....................................57 17.3 SING THE INNER PARTS ..............................58 17.3.1 Mod. HP_OWER ONE 70R - 70RK - 90R - 90RK ....................... 58 17.3.2 Mod. HP_OWER ONE 120R - 120RK.......................... 58 17.3.3 Mod. HP_OWER ONE 140R - 140RK - 160RT - 160RTK - 180RT - 180RTK ............. 59...
  • Page 5: Purpose And Contents Of The Manual

    The manual of HP_OWER ONE units contains all the necessary information for optimal use of the equipment under safe conditions for the operator. 1 PURPOSE AND CONTENTS OF THE MANUAL This manual provides basic information as to the selection, installation, operation and maintenance of heat pumps. It is intended for the operators of the appliance and it enables them to use the equipment efficiently, even if they do not have any previous specific knowledge.
  • Page 6: Permitted Use

    3 PERMITTED USE The company excludes any contractual and extra contractual liability for damage caused to persons, animals or objects, by • incorrect installation, setting and maintenance, improper use of the equipment, and the partial or superficial reading of the information contained in this manual.
  • Page 7: Personal Protective Equipment

     Up to 3kg total refrigerant in the appliance: category 2 certification.  3kg and more total refrigerant in the appliance: category 1 certification. The gaseous form of R32 refrigerant is heavier than air and if released into the environment, most of it tends to concentrate in poorly ventilated areas.
  • Page 8: Refrigerant Safety Data Sheet

    REFRIGERANT SAFETY DATA SHEET Name: R32. HAZARDS IDENTIFICATION Main hazards: Asphyxiation. Specific hazards: Quick evaporation could cause it to freeze. FIRST AID MEASURES General information: Do not administer to people who are unconscious. Inhalation: Immediately remove to fresh air. Use oxygen or artificial respiration as required. The use of adrenaline or similar drugs should be avoided.
  • Page 9: Specific R32 Gas Warnings

    STABILITY AND REACTIVITY Stability: Stable under normal conditions. Materials to avoid: Air, oxidizing agents, humidity. Under normal storage and use conditions, hazardous decomposition products should not be Decomposition products generated. hazardous: TOXICOLOGICAL INFORMATION Acute toxicity: LD/LC50/inhalation/4 hours/on rat >1107000 mg/m Local effects: No known effect.
  • Page 10: Average Versions

    5 AVERAGE VERSIONS Model Description HP_OWER ONE 70R Size 7kW HP_OWER ONE 70RK Size 7kW + Antifreeze kit HP_OWER ONE 90R Size 9kW HP_OWER ONE 90RK Size 9kW + Antifreeze kit HP_OWER ONE 120R Size 12kW HP_OWER ONE 120RK Size 12kW + Antifreeze kit...
  • Page 11: Lifting And Handling

    This is why the Minimum clearances shown below must be strictly guaranteed. MODEL A[mm] B [mm] C [mm] D [mm] E[mm] L[mm] HP_OWER ONE 70R/RK 1500 HP_OWER ONE 90R/RK 1500 HP_OWER ONE 120R/RK 1500 HP_OWER ONE 140R/RK 1500 HP_OWER ONE 160RT/RTK...
  • Page 12: Plumbing Connections

    In the event of side-by-side units, the minimum Lmin distance between them is 1 m. Covering with canopies or placing near plants or walls should be avoided to prevent air recirculation. In the event of winds stronger than 2.2 m/s the use of wind barriers is recommended.
  • Page 13: Features Of The Circuit Water

    CAUTION: when sizing the pipes, make sure not to exceed the maximum pressure drop on plant side reported in the technical data table in Paragraph 0 (see useful head). CAUTION: connect the pipes to their fittings always using the key to key method. CAUTION: The return pipe from the system must be installed near the label “WATER INLET”...
  • Page 14: Filling The System

    Gasket Gasket Hole in bottom panel of outdoor unit Drain fitting Each unit is therefore fitted with a hole on the base of the hydronic kit (on the coil side) to drain condensation which could drip from the pipes of the plumbing system. Since these pipes are well insulated, a minimum amount of condensation is produced anyway and therefore it is not mandatory to connect a drain pipe to this fitting.
  • Page 15: Air Venting Valve

    6.4.6 Air venting valve The unit is fitted with an air venting valve to automatically remove air that has built up in the circuit, preventing undesirable effects such as premature corrosion and wear, lower performance and low exchange output. The device also features a safety function because, in the event of exchanger breakdown, it allows the refrigerant gas to escape outside, preventing it fro being conveyed to the internal terminals.
  • Page 16: Hydraulic Circuit

    6.4.7 HYDRAULIC CIRCUIT HP_OWER ONE 70R - 70RK - 90R - 90RK HP_OWER ONE 120R - 120RK HP_OWER ONE 140R - 140RK - 160RT - 160RTK - 180RT - 180RTK UTILITY INLET TEMPERATURE PROBE TEOE UTILITY OUTLET TEMPERATURE PROBE DRAIN VALVE...
  • Page 17: Refrigerant Diagram Hp_Ower One 70R - 70Rk - 90R - 90Rk

    REFRIGERANT DIAGRAM HP_OWER ONE 70R – 70RK - 90R – 90RK CODE DESCRIPTION CODE DESCRIPTION COMPRESSOR H/CS UTILITY WATER OUTLET CO/EV CONDENSER (IN CHILLER MODE) H/CR UTILITY WATER INLET EV/CO EVAPORATOR (IN CHILLER MODE) PEHTC HIGH PRESSURE TRANSDUCER ELECTRONIC EXPANSION VALVE...
  • Page 18: Refrigerant Diagram Hp_Ower One 120R - 120Rk

    REFRIGERANT DIAGRAM HP_OWER ONE 120R – 120RK REFRIGERANT DIAGRAM HP_OWER ONE 140R - 140RK - 160RT – 160RTK - 180RT - 180RTK...
  • Page 19: Electrical Connections

    ELECTRICAL CONNECTIONS Check that the power supply matches the unit’s electric nominal data (voltage, phases, frequency) displayed on the rating plate on the unit’s side panel. The electric power connections must be made in accordance to the wiring diagram enclosed with the unit and in conformity with national and international standards (providing general circuit breaker, residual current devices for each line, proper earthing of the plant, etc.).
  • Page 20: Power Supply

    Recommended cable Recommendetightening Model Power supply section torque (maximum lenght 30 m) HP_OWER ONE 70R/RK – 90R/RK 230V / 1ph 3 x 4 mm L/N: 3,4 Nm – PE: 1 Nm HP_OWER ONE 120R/RK 230V / 1ph 3 x 4 mm L/N: 3,4 Nm –...
  • Page 21 USER TERMINAL BLOCK: HP_OWER ONE 70R - 70RK - 90R - 90RK - 120R - 120RK - 140R - 140RK HP_OWER ONE 160RT - 160RTK - 180RT - 180RTK...
  • Page 22: Startup

    TERMINAL CONNECTION TYPE Connect the earth cable Power supply Input Connect the neutral cable from the mains 1-Ph/N/PE, 230Vac, 50Hz Connect the phase cable from the mains Connect the earth cable Power supply Input Connect the neutral cable from the mains 3-Ph/N/PE, 400 Vac, 50Hz.
  • Page 23: Switching On The Unit

    CAUTION: The unit must be connected to the electric mains and placed in STANDBY (powered on) by closing the master switch at least 12 hours before start-up. This will allow the heaters to adequately warm up the compressor crankcase (the heaters are powered automatically when the switch is closed). The heaters are working properly if after a few minutes the temperature of the compressor crankcase is 10-15°C higher than ambient temperature.
  • Page 24: Maintenance And Periodic Checks

    10 MAINTENANCE AND PERIODIC CHECKS CAUTION: All the operations described in this chapter MUST BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY. Before performing any intervention on the unit or accessing internal parts, make sure you have disconnected power. The heads and delivery pipe of the compressor are normally quite hot. Be careful when working near the condensing coils.
  • Page 25: Cleaning The Finned Coil

    10.1 CLEANING THE FINNED COIL To correctly clean the coil, follow the instructions below: a) Remove any superficial filth. Debris such as leaves, fibres etc. must be removed without a vacuum cleaner (use a brush or another soft tool carefully avoiding scratching with metal or abrasive parts). If you use compressed air, pay attention to keep the air flow perpendicular to the surface of the coil in order not to bend the aluminium fins.
  • Page 26 An incorrect decommissioning of the appliance may create serious environmental damage and endanger people’s safety. Therefore, it is recommended that the unit be disposed only by authorised persons with technical training who have attended training courses acknowledged by the competent authorities. It is required to follow the same precautions described in the previous paragraphs.
  • Page 27: Residual Risks

    11.1 Residual risks This paragraph sets forth any residual risks which cannot be eliminated by the manufacturer in the design stage. Risk due to: Precautions/Corrections There is always the risk of the unit falling or tipping over during handling. Follow the instructions in the Handling “Handling”...
  • Page 28 Measurement Completed Notes Trigger Sources ■ Never use ignition sources, which could ignite the refrigerant, when carrying out operations on the cooling circuit which contains, or contained, flammable refrigerant. Remove all possible sources of ignition, including cigarettes, from the area where installation, repair, dismantling or disposal operations are being carried out, which may lead to a leak of refrigerant.
  • Page 29 Measurement Completed Notes Repairs on sealed connectors ■ During operations on sealed components, completely isolate the device from the power supply, before removing the sealed covers. ■ If, during operations, the power supply is absolutely necessary: Position a continuously operating refrigerant detector in the most critical places, so that it emits a warning signal in case of potentially dangerous situations.
  • Page 30 Measurement Completed Notes Leak detection The following leak detection methods are suitable for plants with flammable refrigerant: Leak detection by electronic refrigerant leak detector: ■ Electronic refrigerant leak detectors may not have the required sensitivity or may need to be calibrated for the relevant range. Perform the calibration operations in an area free of refrigerant.
  • Page 31 Measurement Completed Notes - The cylinders must be kept vertical. - Make sure that the refrigeration system is grounded before proceeding to recharge the system with the refrigerant fluid. - Label the system when charging is complete, (if not already done). - Particular care must be taken not to overload the refrigeration system.
  • Page 32 Measurement Completed Notes refrigerant fluid storage). The cylinders must be complete with a pressure relief valve and associated shut-off valves, in good working order. The cylinders of Empty cases are collected and, if possible, cooled before recovery takes place. The recovery apparatus must be in good operating condition with a series of instructions relating to the apparatus that is being managed and must be suitable for the recovery of fluids flammable refrigerants.
  • Page 33: Technical Data

    12 TECHNICAL DATA 12.1 TECHNICAL SHEET Model HP_OWER ONE Unit of TECHNICAL SPECIFICATIONS measurement 70R-70RK 90R-90RK 120R-120RK Cooling capacity (1) 4,82 / 6,18 / 6,80* 4,91 / 7,72 / 8,49* 6,41 / 11,60 / 12,76* min/nom/max Input power (1) 1,28 1,76 2,79 E.E.R.
  • Page 34 Model HP_OWER ONE Unit of TECHNICAL SPECIFICATIONS measurement 70R-70RK 90R-90RK 120R-120RK A - Length 1047 B - Depth Dimensions and C - Height weights Shipping weight Operating weight A - Length 1080 Dimensions with B - Depth packaging C - Height 1130 Model HP_OWER ONE Unit of...
  • Page 35: Unit And Auxiliary Electrical Data

    Model HP_OWER ONE Unit of TECHNICAL SPECIFICATIONS measurement 140R-140RK 160RT-160RTK 180RT-180RTK Power supply 230V/1/50Hz 400V/3P+N+T/50Hz 400V/3P+N+T/50Hz Maximum input power Electrical data Maximum input current 28,6 10,1 12,0 Maximum input power (version -K) Maximum input current (version -K) 29,2 10,3 12,2 A - Length 1044 1044...
  • Page 36 Altitude [m] 1000 1500 2000 0,9964 0,9941 0,9888 0,9869 Correction factor Heating Power 0,9931 0,9841 0,9853 0,9755 Correction factor Input Power - Heating 0,9888 0,9762 0,9618 0,9466 Correction factor Cooling Power 1,0106 1,0235 1,0386 1,0560 Correction factor Input Power - Cooling...
  • Page 37: Product Fiche Eu Regulation 811/2013

    13 PRODUCT FICHE EU REGULATION 811/2013 PRODUCT FICHE - HP_OWER ONE MODELS for low-temperature application (Twater=35°C) Supplier's name UNICAL A.G. SPA Model 70R-70RK 90R-90RK 120R-120RK 140R-140RK 160RT-160RTK 180RT-180RTK Seasonal space heating energy efficiency class A+++ A+++ A+++ A+++ A+++ A+++...
  • Page 38 Technical parameters for heat pump space heaters Model HP_OWER ONE 70R - 70RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C...
  • Page 39 Technical parameters for heat pump space heaters Model HP_OWER ONE 90R – 90RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 40 Technical parameters for heat pump space heaters Model HP_OWER ONE 120R – 120RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 41 Technical parameters for heat pump space heaters Model HP_OWER ONE 140R – 140RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 42 Technical parameters for heat pump space heaters Model HP_OWER ONE 160RT – 160RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 43 Technical parameters for heat pump space heaters Model HP_OWER ONE 180RT – 180RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 44 PRODUCT FICHE - HP_OWER ONE MODELS for medium-temperature application (Twater=55°C) Supplier's name UNICAL A.G. SPA Model 70R-70RK 90R-90RK 120R-120RK 140R-140RK 160RT-160RTK 180RT-180RTK Seasonal space heating energy efficiency class Rated heat output average climate conditions 7 kW 7 kW 10 kW...
  • Page 45 Technical parameters for heat pump space heaters Model HP_OWER ONE 70R – 70RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C...
  • Page 46 Technical parameters for heat pump space heaters Model HP_OWER ONE 90R – 90RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 47 Technical parameters for heat pump space heaters Model HP_OWER ONE 120R – 120RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 48 Technical parameters for heat pump space heaters Model HP_OWER ONE 140R – 140RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 49 Technical parameters for heat pump space heaters Model HP_OWER ONE 160RT – 160RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 50 Technical parameters for heat pump space heaters Model HP_OWER ONE 180RT – 180RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
  • Page 51: Hydraulic Circuit Available Head Pressure

    14 HYDRAULIC CIRCUIT AVAILABLE HEAD PRESSURE Below the characteristic curves corresponding to Head pressure -Water flow without head losses of the hydronic kit. The optimal operating point is shown on each curve under the specified conditions at the apex (4). The circuit’s plant must be designed so as to ensure the nominal water flow rate corresponding to the operating points indicated below.
  • Page 52 Here also the range of the available head pressures that the unit can provide during the circulator modulation periode. HP_OWER ONE 70R - 70RK - 90R - 90RK HP_OWER ONE 120R - 120RK...
  • Page 53: Operating Limits

    HP_OWER ONE 140R - 140RK - 160RT -160RTK – 180RT - 180 RTK 15 OPERATING LIMITS 15.1 EVAPORATOR WATER FLOW RATE The nominal water flow rate refers to a 5°C temperature difference between the evaporator inlet and outlet. The maximum permitted flow rate features a 3°C temperature difference while the minimum one has an 8°C temperature difference at the nominal conditions as shown in the technical sheet.
  • Page 54: Cold Water Production (Summer Mode)

    15.2 COLD WATER PRODUCTION (SUMMER MODE) A minimum temperature of 5°C is allowed at the evaporator outlet: for lower temperatures, contact the Technical Department. In this case contact our technical department to study the feasibility and assess the changes to be made according to demands. A maximum temperature of 25°C can be maintained at the evaporator outlet in steady-state operation.
  • Page 55 CHILLER MODE Cooling DOMESTIC HOT WATER MODE...
  • Page 56: Correction Factors For Use Of Glycol

    16 CORRECTION FACTORS FOR USE OF GLYCOL Glycol rate Freezing point (°C) IPCF WFCF PDCF -3,2 0,985 1,02 1,08 -7,8 0,98 0,99 1,05 1,12 -14,1 0,97 0,98 1,10 1,22 -22,3 0,965 0,97 1,14 1,25 -33,8 0,955 0,965 1,33 CCF: Capacity correction factor IPCF: Input power correction factor WFCF: Water flow rate correction factor...
  • Page 57: Dimensions

    17 DIMENSIONS 17.1.1 Model HP_OWER ONE 70R - 70RK - 90R - 90RK IN/OUT: 1”M G E: power supply input...
  • Page 58: Model Hp_Ower One 120R - 120Rk

    17.1.2 Model HP_OWER ONE 120R - 120RK IN/OUT: 1”M G E: power supply input 17.1.3 Model HP_OWER ONE 140R - 140RK - 160RT - 160RTK - 180RT - 180RTK IN/OUT: 1”M G E: power supply input 17.2 A...
  • Page 59: Sing The Inner Parts

    17.3 SING THE INNER PARTS 17.3.1 Mod. HP_OWER ONE 70R - 70RK - 90R - 90RK DETAIL A SCALE 1 : 3 DETAIL B SCALE 1 : 4 Interlocking tab 1) Remove the cover 2) Undo the screws (number 2; 3; 4) of the sheet metal cover of the user interface and the screw (number 1) of the side panel to separate the front sheet metal from the side panel (Detail A).
  • Page 60: Mod. Hp_Ower One 140R - 140Rk - 160Rt - 160Rtk - 180Rt - 180Rtk

    17.3.3 Mod. HP_OWER ONE 140R - 140RK - 160RT - 160RTK - 180RT - 180RTK DETAIL A SCALE 1 : 1 DETAIL B SCALE 1 : 2 1) Remove the cover by undoing the screws (number 1; 2; 3; 4; 5; 6; 7; 8;9). 2) Undo the screws (number 10;...
  • Page 61: Register Of Operations Of Maintenance

    18 REGISTER OF OPERATIONS OF MAINTENANCE...
  • Page 64 - [email protected] - www.unical.eu Unical will not be held responsible for possible inaccuracies if due to transcription or printing errors. It also reserves the right to modify its products as deemed necessary or useful, without jeopardising their essential features.