The manual of HP_OWER ONE units contains all the necessary information for optimal use of the equipment under safe conditions for the operator. 1 PURPOSE AND CONTENTS OF THE MANUAL This manual provides basic information as to the selection, installation, operation and maintenance of heat pumps. It is intended for the operators of the appliance and it enables them to use the equipment efficiently, even if they do not have any previous specific knowledge.
3 PERMITTED USE The company excludes any contractual and extra contractual liability for damage caused to persons, animals or objects, by • incorrect installation, setting and maintenance, improper use of the equipment, and the partial or superficial reading of the information contained in this manual.
Up to 3kg total refrigerant in the appliance: category 2 certification. 3kg and more total refrigerant in the appliance: category 1 certification. The gaseous form of R32 refrigerant is heavier than air and if released into the environment, most of it tends to concentrate in poorly ventilated areas.
REFRIGERANT SAFETY DATA SHEET Name: R32. HAZARDS IDENTIFICATION Main hazards: Asphyxiation. Specific hazards: Quick evaporation could cause it to freeze. FIRST AID MEASURES General information: Do not administer to people who are unconscious. Inhalation: Immediately remove to fresh air. Use oxygen or artificial respiration as required. The use of adrenaline or similar drugs should be avoided.
STABILITY AND REACTIVITY Stability: Stable under normal conditions. Materials to avoid: Air, oxidizing agents, humidity. Under normal storage and use conditions, hazardous decomposition products should not be Decomposition products generated. hazardous: TOXICOLOGICAL INFORMATION Acute toxicity: LD/LC50/inhalation/4 hours/on rat >1107000 mg/m Local effects: No known effect.
This is why the Minimum clearances shown below must be strictly guaranteed. MODEL A[mm] B [mm] C [mm] D [mm] E[mm] L[mm] HP_OWER ONE 70R/RK 1500 HP_OWER ONE 90R/RK 1500 HP_OWER ONE 120R/RK 1500 HP_OWER ONE 140R/RK 1500 HP_OWER ONE 160RT/RTK...
In the event of side-by-side units, the minimum Lmin distance between them is 1 m. Covering with canopies or placing near plants or walls should be avoided to prevent air recirculation. In the event of winds stronger than 2.2 m/s the use of wind barriers is recommended.
CAUTION: when sizing the pipes, make sure not to exceed the maximum pressure drop on plant side reported in the technical data table in Paragraph 0 (see useful head). CAUTION: connect the pipes to their fittings always using the key to key method. CAUTION: The return pipe from the system must be installed near the label “WATER INLET”...
Gasket Gasket Hole in bottom panel of outdoor unit Drain fitting Each unit is therefore fitted with a hole on the base of the hydronic kit (on the coil side) to drain condensation which could drip from the pipes of the plumbing system. Since these pipes are well insulated, a minimum amount of condensation is produced anyway and therefore it is not mandatory to connect a drain pipe to this fitting.
6.4.6 Air venting valve The unit is fitted with an air venting valve to automatically remove air that has built up in the circuit, preventing undesirable effects such as premature corrosion and wear, lower performance and low exchange output. The device also features a safety function because, in the event of exchanger breakdown, it allows the refrigerant gas to escape outside, preventing it fro being conveyed to the internal terminals.
ELECTRICAL CONNECTIONS Check that the power supply matches the unit’s electric nominal data (voltage, phases, frequency) displayed on the rating plate on the unit’s side panel. The electric power connections must be made in accordance to the wiring diagram enclosed with the unit and in conformity with national and international standards (providing general circuit breaker, residual current devices for each line, proper earthing of the plant, etc.).
Recommended cable Recommendetightening Model Power supply section torque (maximum lenght 30 m) HP_OWER ONE 70R/RK – 90R/RK 230V / 1ph 3 x 4 mm L/N: 3,4 Nm – PE: 1 Nm HP_OWER ONE 120R/RK 230V / 1ph 3 x 4 mm L/N: 3,4 Nm –...
TERMINAL CONNECTION TYPE Connect the earth cable Power supply Input Connect the neutral cable from the mains 1-Ph/N/PE, 230Vac, 50Hz Connect the phase cable from the mains Connect the earth cable Power supply Input Connect the neutral cable from the mains 3-Ph/N/PE, 400 Vac, 50Hz.
CAUTION: The unit must be connected to the electric mains and placed in STANDBY (powered on) by closing the master switch at least 12 hours before start-up. This will allow the heaters to adequately warm up the compressor crankcase (the heaters are powered automatically when the switch is closed). The heaters are working properly if after a few minutes the temperature of the compressor crankcase is 10-15°C higher than ambient temperature.
10 MAINTENANCE AND PERIODIC CHECKS CAUTION: All the operations described in this chapter MUST BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY. Before performing any intervention on the unit or accessing internal parts, make sure you have disconnected power. The heads and delivery pipe of the compressor are normally quite hot. Be careful when working near the condensing coils.
10.1 CLEANING THE FINNED COIL To correctly clean the coil, follow the instructions below: a) Remove any superficial filth. Debris such as leaves, fibres etc. must be removed without a vacuum cleaner (use a brush or another soft tool carefully avoiding scratching with metal or abrasive parts). If you use compressed air, pay attention to keep the air flow perpendicular to the surface of the coil in order not to bend the aluminium fins.
Page 26
An incorrect decommissioning of the appliance may create serious environmental damage and endanger people’s safety. Therefore, it is recommended that the unit be disposed only by authorised persons with technical training who have attended training courses acknowledged by the competent authorities. It is required to follow the same precautions described in the previous paragraphs.
11.1 Residual risks This paragraph sets forth any residual risks which cannot be eliminated by the manufacturer in the design stage. Risk due to: Precautions/Corrections There is always the risk of the unit falling or tipping over during handling. Follow the instructions in the Handling “Handling”...
Page 28
Measurement Completed Notes Trigger Sources ■ Never use ignition sources, which could ignite the refrigerant, when carrying out operations on the cooling circuit which contains, or contained, flammable refrigerant. Remove all possible sources of ignition, including cigarettes, from the area where installation, repair, dismantling or disposal operations are being carried out, which may lead to a leak of refrigerant.
Page 29
Measurement Completed Notes Repairs on sealed connectors ■ During operations on sealed components, completely isolate the device from the power supply, before removing the sealed covers. ■ If, during operations, the power supply is absolutely necessary: Position a continuously operating refrigerant detector in the most critical places, so that it emits a warning signal in case of potentially dangerous situations.
Page 30
Measurement Completed Notes Leak detection The following leak detection methods are suitable for plants with flammable refrigerant: Leak detection by electronic refrigerant leak detector: ■ Electronic refrigerant leak detectors may not have the required sensitivity or may need to be calibrated for the relevant range. Perform the calibration operations in an area free of refrigerant.
Page 31
Measurement Completed Notes - The cylinders must be kept vertical. - Make sure that the refrigeration system is grounded before proceeding to recharge the system with the refrigerant fluid. - Label the system when charging is complete, (if not already done). - Particular care must be taken not to overload the refrigeration system.
Page 32
Measurement Completed Notes refrigerant fluid storage). The cylinders must be complete with a pressure relief valve and associated shut-off valves, in good working order. The cylinders of Empty cases are collected and, if possible, cooled before recovery takes place. The recovery apparatus must be in good operating condition with a series of instructions relating to the apparatus that is being managed and must be suitable for the recovery of fluids flammable refrigerants.
12 TECHNICAL DATA 12.1 TECHNICAL SHEET Model HP_OWER ONE Unit of TECHNICAL SPECIFICATIONS measurement 70R-70RK 90R-90RK 120R-120RK Cooling capacity (1) 4,82 / 6,18 / 6,80* 4,91 / 7,72 / 8,49* 6,41 / 11,60 / 12,76* min/nom/max Input power (1) 1,28 1,76 2,79 E.E.R.
Page 34
Model HP_OWER ONE Unit of TECHNICAL SPECIFICATIONS measurement 70R-70RK 90R-90RK 120R-120RK A - Length 1047 B - Depth Dimensions and C - Height weights Shipping weight Operating weight A - Length 1080 Dimensions with B - Depth packaging C - Height 1130 Model HP_OWER ONE Unit of...
Model HP_OWER ONE Unit of TECHNICAL SPECIFICATIONS measurement 140R-140RK 160RT-160RTK 180RT-180RTK Power supply 230V/1/50Hz 400V/3P+N+T/50Hz 400V/3P+N+T/50Hz Maximum input power Electrical data Maximum input current 28,6 10,1 12,0 Maximum input power (version -K) Maximum input current (version -K) 29,2 10,3 12,2 A - Length 1044 1044...
13 PRODUCT FICHE EU REGULATION 811/2013 PRODUCT FICHE - HP_OWER ONE MODELS for low-temperature application (Twater=35°C) Supplier's name UNICAL A.G. SPA Model 70R-70RK 90R-90RK 120R-120RK 140R-140RK 160RT-160RTK 180RT-180RTK Seasonal space heating energy efficiency class A+++ A+++ A+++ A+++ A+++ A+++...
Page 38
Technical parameters for heat pump space heaters Model HP_OWER ONE 70R - 70RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C...
Page 39
Technical parameters for heat pump space heaters Model HP_OWER ONE 90R – 90RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 40
Technical parameters for heat pump space heaters Model HP_OWER ONE 120R – 120RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 41
Technical parameters for heat pump space heaters Model HP_OWER ONE 140R – 140RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 42
Technical parameters for heat pump space heaters Model HP_OWER ONE 160RT – 160RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 43
Technical parameters for heat pump space heaters Model HP_OWER ONE 180RT – 180RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for low-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 44
PRODUCT FICHE - HP_OWER ONE MODELS for medium-temperature application (Twater=55°C) Supplier's name UNICAL A.G. SPA Model 70R-70RK 90R-90RK 120R-120RK 140R-140RK 160RT-160RTK 180RT-180RTK Seasonal space heating energy efficiency class Rated heat output average climate conditions 7 kW 7 kW 10 kW...
Page 45
Technical parameters for heat pump space heaters Model HP_OWER ONE 70R – 70RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C...
Page 46
Technical parameters for heat pump space heaters Model HP_OWER ONE 90R – 90RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 47
Technical parameters for heat pump space heaters Model HP_OWER ONE 120R – 120RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 48
Technical parameters for heat pump space heaters Model HP_OWER ONE 140R – 140RK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 49
Technical parameters for heat pump space heaters Model HP_OWER ONE 160RT – 160RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
Page 50
Technical parameters for heat pump space heaters Model HP_OWER ONE 180RT – 180RTK Air-to-water heat pump Sì Water-to-water heat pump Brine-to-water heat pump Low-temperature heat pump Equipped with a supplementary heater Heat pump combination heater Parameters shall be declared for medium-temperature application 35°C Parameters shall be declared for average climate condition Item Symbol...
14 HYDRAULIC CIRCUIT AVAILABLE HEAD PRESSURE Below the characteristic curves corresponding to Head pressure -Water flow without head losses of the hydronic kit. The optimal operating point is shown on each curve under the specified conditions at the apex (4). The circuit’s plant must be designed so as to ensure the nominal water flow rate corresponding to the operating points indicated below.
Page 52
Here also the range of the available head pressures that the unit can provide during the circulator modulation periode. HP_OWER ONE 70R - 70RK - 90R - 90RK HP_OWER ONE 120R - 120RK...
HP_OWER ONE 140R - 140RK - 160RT -160RTK – 180RT - 180 RTK 15 OPERATING LIMITS 15.1 EVAPORATOR WATER FLOW RATE The nominal water flow rate refers to a 5°C temperature difference between the evaporator inlet and outlet. The maximum permitted flow rate features a 3°C temperature difference while the minimum one has an 8°C temperature difference at the nominal conditions as shown in the technical sheet.
15.2 COLD WATER PRODUCTION (SUMMER MODE) A minimum temperature of 5°C is allowed at the evaporator outlet: for lower temperatures, contact the Technical Department. In this case contact our technical department to study the feasibility and assess the changes to be made according to demands. A maximum temperature of 25°C can be maintained at the evaporator outlet in steady-state operation.
Page 55
CHILLER MODE Cooling DOMESTIC HOT WATER MODE...
17.1.2 Model HP_OWER ONE 120R - 120RK IN/OUT: 1”M G E: power supply input 17.1.3 Model HP_OWER ONE 140R - 140RK - 160RT - 160RTK - 180RT - 180RTK IN/OUT: 1”M G E: power supply input 17.2 A...
17.3 SING THE INNER PARTS 17.3.1 Mod. HP_OWER ONE 70R - 70RK - 90R - 90RK DETAIL A SCALE 1 : 3 DETAIL B SCALE 1 : 4 Interlocking tab 1) Remove the cover 2) Undo the screws (number 2; 3; 4) of the sheet metal cover of the user interface and the screw (number 1) of the side panel to separate the front sheet metal from the side panel (Detail A).
Page 64
- [email protected] - www.unical.eu Unical will not be held responsible for possible inaccuracies if due to transcription or printing errors. It also reserves the right to modify its products as deemed necessary or useful, without jeopardising their essential features.