  • Page 1 YASKAWA AC Drive-J1000 Option RS-232C Interface Technical Manual Type SI-232/J, SI-232/JC To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. J1000 MANUAL NO. TOBP C730600 32A...
  • Page 2 Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is...
  • Page 3: Table Of Contents

    7 TROUBLESHOOTING ..20 8 SPECIFICATIONS ... .21 9 YASKAWA LOCATIONS..22 10 REVISION HISTORY ..23...
  • Page 4: Preface And Safety

    Yaskawa AC Drive -RS-232C Interface Option Technical Manual J1000 Read this manual first. The Technical Manual is packaged with the RS-232C Interface Option and contains a basic overview of wiring, settings, functions, and fault diagnoses. YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 5 Yaskawa representative. ◆ Terms Note: Indicates a supplement or precaution that does not cause drive damage. Drive: Yaskawa AC Drive -J1000 Series Yaskawa AC Drive -J1000 RS-232C Interface Option: Option YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 6 DANGER Indicates a hazardous situation, which, if not avoided, will result in death or serious injury. W ARNING Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 7 1 Preface and Safety CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. NOTICE Indicates an equipment damage message. YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 8: Receiving

    U.S. PC Interface WV103 D-sub 9 pin - RJ-45 Cable Provided with an RJ-45 cable USB Copy Unit JVOP-181 and a USB cable Available soon LED Operator JVOP-182 (Contact Yaskawa for details) YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 9 WV003 ◆ Tool Requirements Use a flat-blade screwdriver with the dimensions below for installation or removal of the option cover and RS-232C option. Blade width 3.0 mm max. Blade thickness 0.6 mm max. YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 10: Product Overview

    SI-232/JC is more easily connected and disconnected than SI-232/ J. This is useful when copying parameter settings between multiple drives. ◆ Applicable Models The RS-232C Option is used with these Yaskawa drive models. Drive Drive Software Version <1> ≥1010 CIMR-J <1>...
  • Page 11: Option Components

    Figure 1 J1000 A – RJ-45 Port C – Drive Connector B – Option D – Connection Model Tabs <1> Number <1> Connection tabs are found only on the RS-232C interface (SI- 232/J). YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 12 4 Option Components ◆ Dimensions The installed Option interface adds 17.8 mm (0.70 in) to the total depth of the drive. 2.8(0.11) 15(0.60) mm(in) YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 13: Installation Procedure

    The drive charge LED will extinguish when the DC bus voltage is below 50Vdc. Measure drive DC bus voltage to confirm safe level. YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 14 5 Installation Procedure NOTICE Damage to Equipment Use only Yaskawa connection cables or recommended cables. Failure to comply may cause the drive or option to function incorrectly. Properly connect the connectors. Failure to comply may prevent proper operation and possibly damage equipment.
  • Page 15 Insert the connector on the back of the interface into the CN5 port and click into position. Note: The RS-232C Interface (SI-232/J) has three additional connection tabs that must also click into place to properly mount the option.
  • Page 16 Removing the option interface Use a flat-blade screwdriver as shown in the diagram to press gently against the small openings and disconnect the option unit. J 1 0 underside of interface unit flat-blade screwdriver YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 17 5 Installation Procedure ◆ Connecting Peripheral Devices to the RS-232C Interface Option NOTICE: Only use specific cables recommended by Yaskawa. Yaskawa cannot guarantee proper operation if non-specified cables are used. AC drive J1000 connect SI-232/JC SI-232/J J1000 J1000 <4> <1>...
  • Page 18 <2> Only use the RJ-45 cable supplied with the USB Copy Unit. <3> Only use the USB cable supplied with the USB Copy Unit. <4> Only use the cable, PN: WV103, when connecting the drive to a PC. YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 19: Related Drive Parameters

    0: Disabled - The drive will o2-06 when Digital not stop when the digital Operator is operator is removed. Disconnected 1: Enabled - The drive will fault (OPR) and coast to stop when the digital operator is removed. YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 20: Troubleshooting

    • Turn off the drive input power and drive or cables are disconnect the LED operator damaged • Next reconnect the operator and turn the drive input power back on YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 21: Specifications

    8 Specifications 8 Specifications ◆ Drive Specification Item Specification SI-232/J: RS-232C Interface for use with remote Model digital operator Number SI-232/JC: RS-232C Interface for use with copy unit and PC communication Storage/ Installation Indoors (an area free from oil mist and dust)
  • Page 22: Yaskawa Locations

    No.18 Xizang Zhong Road. Room 1702-1707, Harbour Ring Plaza Shanghai 200001, China Phone 86-21-5385-2200 Fax 86-21-5385-3299 YASKAWA ELECTRIC (SHANGHAI) CO., LTD. BEIJING OFFICE Room 1011A, Tower W3 Oriental Plaza, No.1 East Chang An Ave., Dong Cheng District, Beijing 100738, China...
  • Page 23: Revision History

    MANUAL NO. TOBP C730600 32A Published in Japan December 2007 07-12 Date of publication Date of original publication Date of Rev. Section Revised Content Publication December 2007 – – First edition YASKAWA ELECTRIC TOBPC73060032A RS-232C Interface Technical Manual...
  • Page 24 Specifications are subject to change without notice for ongoing product modifications and improvements. © 2007 YASKAWA ELECTRIC CORPORATION. All rights reserved. MANUAL NO. TOBP C730600 32A...