Summary of Contents for Fujitsu ASYG30KMTA

  • Page 1 AIR CONDITIONER Wall mounted type SERVICE MANUAL INDOOR ASYG30KMTA ASYG36KMTA OUTDOOR AOYG30KMTA AOYG36KMTA SR_AS019EF_02 2019.12.24...
  • Page 2 • Product specifications and design are subject to change without notice for future improvement. • For further details, please check with our authorized dealer. Trademarks The following term and logo are trademarks of Fujitsu General Limited in the United States, other countries or both: ™...
  • Page 3 CONTENTS 1. GENERAL INFORMATION 2. TECHNICAL DATA AND PARTS LIST...
  • Page 5 1. GENERAL INFORMATION 2019.11.20 SR_CH01_AS019EF_01...
  • Page 6: Table Of Contents

    CONTENTS 1. GENERAL INFORMATION 1. Specifications....................01-1 1-1. Indoor units........................01-1 1-2. Outdoor units ........................01-3 2. Dimensions....................01-4 2-1. Indoor unit ........................01-4 2-2. Outdoor unit........................01-6...
  • Page 7: Specifications

    1. Specifications 1-1. Indoor units Wall mounted Type Inverter heat pump Model name ASYG30KMTA ASYG36KMTA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Rated Btu/h 27,300 32,100 Cooling 2.9—9.0 2.9—10.0 Min.—Max.
  • Page 8 Specifications for ErP Lot 10 Model name ASYG30KMTA ASYG36KMTA Cooling Energy efficiency class Heating (Average) Cooling 8.00 9.40 Pdesign Heating (Average) 6.50 7.10 SEER Cooling 6.67 6.14 kWh/kWh SCOP Heating (Average) 4.54 4.52 Annual energy consumption kWh/a QHE (Average) 2,001...
  • Page 9: Outdoor Units

    1-2. Outdoor units Type Inverter heat pump Model name AOYG30KMTA AOYG36KMTA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Starting current 10.2 13.9 Cooling 3,750 Airflow rate Heating 3,750 Type × Q'ty Propeller ×...
  • Page 10: Dimensions

    2. Dimensions 2-1. Indoor unit ¢ Models: ASYG30KMTA and ASYG36KMTA Unit: mm 1,150 1,150 Outline of unit - (01-4) - 2-1. Indoor unit 2. Dimensions...
  • Page 11  Installation space requirement Provide sufficient installation space for product safety. Unit: mm Outline of unit 50 or more 50 or more 70 or more 140 or more 1,500 or more - (01-5) - 2-1. Indoor unit 2. Dimensions...
  • Page 12: Outdoor Unit

    2-2. Outdoor unit ¢ Models: AOYG30KMTA and AOYG36KMTA Unit: mm 35.7 Top view 3 Way valve (Liquid) 3 Way valve (Gas) 25 67 Ф28: Cable port Pipe port Ф28: Cable port Ф28: Cable port Ф28: Cable port Ф28: Cable port Ф28: Cable port Pipe port Pipe port...
  • Page 13 2. TECHNICAL DATA AND PARTS LIST 2019.11.20 SR_CH02_AS019EF_01...
  • Page 14 CONTENTS 2. TECHNICAL DATA AND PARTS LIST 1. Precautions....................02-1 2. Indoor unit parts list..................02-2 2-1. Models: ASYG30KMTA and ASYG36KMTA ..............02-2 3. Outdoor unit parts list.................02-6 3-1. Models: AOYG30KMTA and AOYG36KMTA ..............02-6 4. Accessories ....................02-10 4-1. Indoor unit ........................02-10 4-2. Outdoor unit........................02-10 5.
  • Page 15: Precautions

    • Service parts information and design are subject to change without notice for product improve- ment. • For the latest information of the service parts, refer to our Service Portal. https://fujitsu-general.force.com/portal/ • Precise figure of the service parts listed in this manual may differ from the actual service parts. - (02-1) -...
  • Page 16: Indoor Unit Parts List

    2. Indoor unit parts list 2-1. Models: ASYG30KMTA and ASYG36KMTA ¢ Exterior parts - (02-2) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
  • Page 17 9387074017 Wire cover assy ♦ 9315212016 Air clean filter assy ♦ 9318912005 Remote controller holder ♦ 9383712005 Remote controller ♦ — Casing — — Front panel — - (02-3) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
  • Page 18 ¢ Evaporator and control - (02-4) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
  • Page 19 Evaporator total assy ♦ 9361756007 Insulation(drain)-T ♦ — Rear panel — — Box shield assy — — Control box — — PCB holder A — — Control cover — - (02-5) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
  • Page 20: Outdoor Unit Parts List

    3. Outdoor unit parts list 3-1. Models: AOYG30KMTA and AOYG36KMTA ¢ Exterior parts and chassis - (02-6) - 3-1. Models: AOYG30KMTA and AOYG36KMTA 3. Outdoor unit parts list...
  • Page 21 Item no. Part no. Part name Service part 9383880001 Top panel assy ♦ 9383779008 Protective net ♦ 9375361013 Net rubber ♦ 9900984038 Thermistor (Heat exchanger) ♦ 9900727154 Thermistor assy ♦ 9383607004 Thermo holder ♦ 9383874000 Right panel sub assy ♦ 9383879005 Rear pipe cover ♦...
  • Page 22 ¢ Compressor - (02-8) - 3-1. Models: AOYG30KMTA and AOYG36KMTA 3. Outdoor unit parts list...
  • Page 23 Item no. Part no. Part name Service part 9383858000 Sound insulation unit ♦ 9900565091 Thermistor (Outdoor temp.) ♦ 9900186029 Pressure switch ♦ 9374425648 4-way valve assy ♦ 9970194016 Solenoid ♦ 9375250140 Accumulator assy ♦ 9970209000 Expansion valve coil ♦ 9370947328 Expansion valve assy ♦...
  • Page 24: Accessories

    4. Accessories 4-1. Indoor unit ¢ Models: ASYG30KMTA and ASYG36KMTA Part name Exterior Q’ty Part name Exterior Q’ty Operating manual Drain hose insulation Installation manual Cloth tape Wall hook bracket Tapping screw (large) Remote controller Tapping screw (small) Battery Air cleaning filters...
  • Page 25: Optional Parts

    5. Optional parts 5-1. Indoor unit ¢ Controllers Exterior Part name Model name Summary Easy finger touch operation with LCD panel. Backlit LCD enables easy operation in a dark room. Wired remote UTY-RNRYZ* Wire type: Non-polar 2-wire controller Optional communication kit is necessary for installation.
  • Page 26 ¢ Others Exterior Part name Model name Summary Required when external device is External connected. UTY-XWZXZ5 connect kit Use to connect with external devices External input and air conditioner PCB. UTY-XCSXZ2 and output PCB Optional External connect kit is necessary for installation. Communication Use to connect Non-polar 2-core wired UTY-TWRXZ2...
  • Page 27: Refrigerant System Diagrams

    6. Refrigerant system diagrams 6-1. Models: AOYG30KMTA and AOYG36KMTA Heat exchanger 3-Way ( INDOOR ) valve 2-Way valve Pressure switch 4-Way valve Strainer Expansion valve Heat exchanger Strainer ( OUTDOOR ) : Cooling : Heating : Thermistor (Compressor temperature) : Thermistor (Discharge temperature) : Thermistor (Outdoor temperature) : Thermistor (Heat Exchanger Out temperature) : Thermistor (Room temperature)
  • Page 28: Wiring Diagrams

    7. Wiring diagrams 7-1. Indoor unit ¢ Models: ASYG30KMTA and ASYG36KMTA - (02-14) - 7-1. Indoor unit 7. Wiring diagrams...
  • Page 29: Outdoor Unit

    7-2. Outdoor unit ¢ Models: AOYG30KMTA and AOYG36KMTA - (02-15) - 7-2. Outdoor unit 7. Wiring diagrams...
  • Page 30: Pc Board Diagrams

    8. PC board diagrams - (02-16) - 8. PC board diagrams...
  • Page 31: Models: Asyg30Kmta And Asyg36Kmta

    8-1. Models: ASYG30KMTA and ASYG36KMTA CONTROL UNIT 30 model : EZ-01909HSE 36 model : EZ-0190AHSE 2-WIRE REMOTE CONTROL UNIT ( OPTION ) UTY-TWRXZ2 UL1007 AWG22 CN300 REMOTE CN13 UL1007 AWG22 WHITE B03B-XNISK-A-1 CONTROLLER UL1061 AWG26 B07B-PASK-1 CN301 WHITE ( 2-WIRE )
  • Page 32: Models: Aoyg30Kmta And Aoyg36Kmta

    8-2. Models: AOYG30KMTA and AOYG36KMTA INVERTER ASSEMBLY 30 model : EZ-0190DHUE 36 model : EZ-01915HUE P700 Thermistor Characteristics. Temperature Thermistor 0.33 k 0.12 k 0.08 k Thermistor ( Heatsink temp. ) 4.10 4.62 4.75 UL1015 5V-1 AWG20 GREEN BLACK P700 THERMISTOR ( HEATSINK TEMP.