Page 1
AIR CONDITIONER Wall mounted type SERVICE MANUAL INDOOR ASYG30KMTA ASYG36KMTA OUTDOOR AOYG30KMTA AOYG36KMTA SR_AS019EF_02 2019.12.24...
Page 2
• Product specifications and design are subject to change without notice for future improvement. • For further details, please check with our authorized dealer. Trademarks The following term and logo are trademarks of Fujitsu General Limited in the United States, other countries or both: ™...
Page 3
CONTENTS 1. GENERAL INFORMATION 2. TECHNICAL DATA AND PARTS LIST...
Page 5
1. GENERAL INFORMATION 2019.11.20 SR_CH01_AS019EF_01...
1. Specifications 1-1. Indoor units Wall mounted Type Inverter heat pump Model name ASYG30KMTA ASYG36KMTA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Rated Btu/h 27,300 32,100 Cooling 2.9—9.0 2.9—10.0 Min.—Max.
Page 8
Specifications for ErP Lot 10 Model name ASYG30KMTA ASYG36KMTA Cooling Energy efficiency class Heating (Average) Cooling 8.00 9.40 Pdesign Heating (Average) 6.50 7.10 SEER Cooling 6.67 6.14 kWh/kWh SCOP Heating (Average) 4.54 4.52 Annual energy consumption kWh/a QHE (Average) 2,001...
1-2. Outdoor units Type Inverter heat pump Model name AOYG30KMTA AOYG36KMTA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Starting current 10.2 13.9 Cooling 3,750 Airflow rate Heating 3,750 Type × Q'ty Propeller ×...
2. Dimensions 2-1. Indoor unit ¢ Models: ASYG30KMTA and ASYG36KMTA Unit: mm 1,150 1,150 Outline of unit - (01-4) - 2-1. Indoor unit 2. Dimensions...
Page 11
Installation space requirement Provide sufficient installation space for product safety. Unit: mm Outline of unit 50 or more 50 or more 70 or more 140 or more 1,500 or more - (01-5) - 2-1. Indoor unit 2. Dimensions...
2-2. Outdoor unit ¢ Models: AOYG30KMTA and AOYG36KMTA Unit: mm 35.7 Top view 3 Way valve (Liquid) 3 Way valve (Gas) 25 67 Ф28: Cable port Pipe port Ф28: Cable port Ф28: Cable port Ф28: Cable port Ф28: Cable port Ф28: Cable port Pipe port Pipe port...
Page 13
2. TECHNICAL DATA AND PARTS LIST 2019.11.20 SR_CH02_AS019EF_01...
Page 14
CONTENTS 2. TECHNICAL DATA AND PARTS LIST 1. Precautions....................02-1 2. Indoor unit parts list..................02-2 2-1. Models: ASYG30KMTA and ASYG36KMTA ..............02-2 3. Outdoor unit parts list.................02-6 3-1. Models: AOYG30KMTA and AOYG36KMTA ..............02-6 4. Accessories ....................02-10 4-1. Indoor unit ........................02-10 4-2. Outdoor unit........................02-10 5.
• Service parts information and design are subject to change without notice for product improve- ment. • For the latest information of the service parts, refer to our Service Portal. https://fujitsu-general.force.com/portal/ • Precise figure of the service parts listed in this manual may differ from the actual service parts. - (02-1) -...
2. Indoor unit parts list 2-1. Models: ASYG30KMTA and ASYG36KMTA ¢ Exterior parts - (02-2) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
Page 17
9387074017 Wire cover assy ♦ 9315212016 Air clean filter assy ♦ 9318912005 Remote controller holder ♦ 9383712005 Remote controller ♦ — Casing — — Front panel — - (02-3) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
Page 18
¢ Evaporator and control - (02-4) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
Page 19
Evaporator total assy ♦ 9361756007 Insulation(drain)-T ♦ — Rear panel — — Box shield assy — — Control box — — PCB holder A — — Control cover — - (02-5) - 2-1. Models: ASYG30KMTA and ASYG36KMTA 2. Indoor unit parts list...
3. Outdoor unit parts list 3-1. Models: AOYG30KMTA and AOYG36KMTA ¢ Exterior parts and chassis - (02-6) - 3-1. Models: AOYG30KMTA and AOYG36KMTA 3. Outdoor unit parts list...
Page 21
Item no. Part no. Part name Service part 9383880001 Top panel assy ♦ 9383779008 Protective net ♦ 9375361013 Net rubber ♦ 9900984038 Thermistor (Heat exchanger) ♦ 9900727154 Thermistor assy ♦ 9383607004 Thermo holder ♦ 9383874000 Right panel sub assy ♦ 9383879005 Rear pipe cover ♦...
Page 22
¢ Compressor - (02-8) - 3-1. Models: AOYG30KMTA and AOYG36KMTA 3. Outdoor unit parts list...
Page 23
Item no. Part no. Part name Service part 9383858000 Sound insulation unit ♦ 9900565091 Thermistor (Outdoor temp.) ♦ 9900186029 Pressure switch ♦ 9374425648 4-way valve assy ♦ 9970194016 Solenoid ♦ 9375250140 Accumulator assy ♦ 9970209000 Expansion valve coil ♦ 9370947328 Expansion valve assy ♦...
5. Optional parts 5-1. Indoor unit ¢ Controllers Exterior Part name Model name Summary Easy finger touch operation with LCD panel. Backlit LCD enables easy operation in a dark room. Wired remote UTY-RNRYZ* Wire type: Non-polar 2-wire controller Optional communication kit is necessary for installation.
Page 26
¢ Others Exterior Part name Model name Summary Required when external device is External connected. UTY-XWZXZ5 connect kit Use to connect with external devices External input and air conditioner PCB. UTY-XCSXZ2 and output PCB Optional External connect kit is necessary for installation. Communication Use to connect Non-polar 2-core wired UTY-TWRXZ2...
8-1. Models: ASYG30KMTA and ASYG36KMTA CONTROL UNIT 30 model : EZ-01909HSE 36 model : EZ-0190AHSE 2-WIRE REMOTE CONTROL UNIT ( OPTION ) UTY-TWRXZ2 UL1007 AWG22 CN300 REMOTE CN13 UL1007 AWG22 WHITE B03B-XNISK-A-1 CONTROLLER UL1061 AWG26 B07B-PASK-1 CN301 WHITE ( 2-WIRE )
8-2. Models: AOYG30KMTA and AOYG36KMTA INVERTER ASSEMBLY 30 model : EZ-0190DHUE 36 model : EZ-01915HUE P700 Thermistor Characteristics. Temperature Thermistor 0.33 k 0.12 k 0.08 k Thermistor ( Heatsink temp. ) 4.10 4.62 4.75 UL1015 5V-1 AWG20 GREEN BLACK P700 THERMISTOR ( HEATSINK TEMP.