Revision Revision This revision applies to the following documentation: Operating instructions ® "MOVIPRO ADC", part number 22749055/EN, edition 04/2016. Replacements • Chapter 3.1 is replaced by "Type designation" (→ 2 5) • Chapter 3.5.2 is replaced by "Communication and control unit" (→ 2 6) • Chapter 3.7.2 is replaced by "Accessory components" (→ 2 8) •...
Device structure Type designations of the function units Type designations of the function units 2.2.1 Communication and control unit Control/communication – Fieldbus: PROFIBUS DP‑V1 DeviceNet™ PROFINET IO EtherNet/IP™/Modbus TCP SBus Control type: Slave gateway Storage medium: SD memory card OMH for parameterizable and programmable functions DIP switch Technology level:...
Page 7
Device structure Type designations of the function units Communication package: Without communication package PLUS SBus interface CAN interface – external (electrically isolated) RS485 interface – external (electrically isolated) PLUS SBus interface CAN interface – external (electrically isolated) S485 interface – external (with DC 24 V) PLUS SBus interface...
Device structure Accessory components Accessory components The following accessories are available depending on the device design. For further ® information, refer to the following documentation: “MOVIPRO Accessories” ad- dendum to operating instructions. If you are not sure which accessories you need, the SEW‑EURODRIVE staff will be glad to help you with your selection.
Device structure Communication unit Part number Mounting bracket kit, BW sizes 1 and 2 18229689 Connection components STO jumper plug 11747099 Fan subassembly Fan subassembly 12709700 Communication unit 2.4.1 Control type The device is equipped with an SBus slave controller-type control. The slave controller is used to connect several devices to a master controller.
Integrated safety technology Prerequisites Integrated safety technology Prerequisites INFORMATION Startup must be performed correctly, to prevent hazards caused by failure of the safety components. Only use the device in combination with functional safety techno- logy if you have read the "Functional Safety" manual and if all requirements for operation are fulfilled.
Integrated safety technology Safety concept 3.4.1 Additional safety function Depending on the device configuration, additional drive-related safety functions can be used: • SBC (Safe Brake Control): Safe brake control according to EN 61800‑5‑2 Refer to the type designation of the "power section" function unit to find out if your device is configured for this: Type designation "power section"...
Electrical installation Connection blocks Electrical installation Connection blocks The connection designation of your device is specified on the connection block label on the front of the device. Make sure that the latches of the connections engage after you plugged the plug con- nector into the connections.
Page 13
Electrical installation Connection blocks 4 kW, 7.5 kW [9] [8] 21833310475 → Encoder option connections X4102 CAN bus – system bus X4101 CAN bus – system bus X2012 Motor with brake control (→ 2 37) → "PC/laptop connection" (→ 2 63) X1213 AC 400 V input/DC 24 V supply for interface box (up to 22 kW - coded) (→ 2 17) X1214 AC 400 V input/DC 24 V supply for supply cable (up to 22 kW - coded)
Page 14
Electrical installation Connection blocks 11 kW, 15 kW, 22 kW [10] 21833341067 → Encoder option connections X4102 CAN bus – system bus X4101 CAN bus – system bus X2016 Motor with brake control (→ 2 48) → "PC/laptop connection" (→ 2 63) X1213 AC 400 V input/DC 24 V supply for interface box (up to 22 kW - coded) (→ 2 17) X1214 AC 400 V input/DC 24 V supply for supply cable (up to 22 kW - coded)
Page 15
Electrical installation Connection blocks 4.1.2 Fieldbus connections Depending on the design, the device has the following fieldbus connections: PROFIBUS Connections Fieldbus Function unit [1] X4201 – input PROFIBUS PFH-P1.A..-B11-I1.. [2] X4202 – output DeviceNet™ Connections Fieldbus Function unit [1] X4241 – input DeviceNet™...
Page 16
Electrical installation Connection blocks Push-pull SCRJ Connections Fieldbus Function unit [1] X4234_11 Ethernet fieldbus, PFH-E2.A..-B64-I1.. [2] X4234_12 Push-pull SCRJ/POF EtherNet/IP™, Modbus/TCP Connections Fieldbus Function unit [1] X4233_11 Ethernet fieldbus, PFH-E3.A..-B53-I1.. [2] X4233_12 Push-pull RJ45 Connections Fieldbus Function unit [1] X4232_11 Ethernet fieldbus, PFH-E3.A..-B63-I1..
Electrical installation X1213: AC 400 V input/DC 24 V supply for interface box X1213: AC 400 V input/DC 24 V supply for interface box Function • AC 400 V input to supply devices up to 22 kW • DC 24 V output and input • Signal contact for external maintenance switch •...
Page 18
Electrical installation X1213: AC 400 V input/DC 24 V supply for interface box Hinged frame Name Function – PE connection 4.2.1 Coding The following table shows the assignment of the different coding to the respective device power ratings and the corresponding power interfaces: Device power Coding of the connections Interface box...
Page 19
Electrical installation X1213: AC 400 V input/DC 24 V supply for interface box Device power Coding of the connections Interface box PZM2xA-A150-D03-00 11 kW PZM2xA-A220-D04-00 PZM2xA-A150-D03-00 15 kW PZM2xA-A220-D04-00 22 kW PZM2xA-A220-D04-00 ® Revision – MOVIPRO...
Page 20
Electrical installation X1213: AC 400 V input/DC 24 V supply for interface box 4.2.2 Interface box connections 45035998228608907 Covers of the screw fitting holes (M25 × 1.5) Covers of the screw fitting holes (M32 × 1.5) Terminal strip, power input ® ® Connection to MOVIPRO (Han 10 B, female) 1) The screw fittings are not included in the scope of delivery.
Page 21
Electrical installation X1213: AC 400 V input/DC 24 V supply for interface box 4.2.3 X1 terminal strip of the interface box [10] 27021599719541387 Terminal strip X1 (power input terminal strip) Terminal cross section Name Function VO24 DC 24 V output 0.2 – 6 mm Reference potential/DC 24 V output +24V_C DC 24 V input 0V24_C 0V24 reference potential –...
Page 22
Electrical installation X1213: AC 400 V input/DC 24 V supply for interface box 4.2.4 DC 24 V supply ® The MOVIPRO is equipped with a DC 24 V output that can be used to supply the ® MOVIPRO from the DC link. To use the DC 24 V supply from the DC link, you must jumper the following terminals in the interface box: •...
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable X1214: AC 400 V input/DC 24 V supply for supply cable Function • AC 400 V input to supply devices up to 22 kW • Output and input for DC 24 V • Signal contact for external maintenance switch •...
Page 24
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable Hinged frame Name Function – PE connection 4.3.1 Important information about the DC 24 V supply The internal components can be supplied with DC 24 V either from the device or via an external DC 24 V backup voltage.
Page 25
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable If you do not use an external maintenance switch, you must jumper the DC 24 V to the signal contact (SC). Connection variant Connection variant DC 24 V supply external DC 24 V supply internal X1214 X1214...
Page 26
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable Device power Coding of the connections 4 kW 7.5 kW 11 kW 15 kW ® Revision – MOVIPRO...
Page 27
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable Device power Coding of the connections 22 kW 4.3.4 Connection cable 2.2 kW/4 kW device power IEC/UL Cables Length/installation Type Component type Part number: 18131433 Cable design: 4G2.5 Variable length D/2.5 – ®...
Page 28
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable 7.5 kW device power UL Cables Length/installation Type Component type Part number: 18195237 Cable design: 4G4.0 Variable length – ® 10 B ↔ open with conductor end sleeves Part number: 18195253 Cable design: 4G4.0 Variable length –...
Page 29
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable 11 kW device power UL Cables Length/installation Type Component type Part number: 18174183 Cable design: 4G6.0 Variable length – ® 10 B ↔ open with conductor end sleeves Part number: 18131468 Cable design: 4G6.0 Variable length –...
Page 30
Electrical installation X1214: AC 400 V input/DC 24 V supply for supply cable Conductor assignment Part number Signal name Core color 18131433 Black/1 18131468 Black/2 18174183 Black/3 18195237 Green/yellow 18195253 Wiring diagram The following figure shows the wiring diagram of the connection cables. 14792950155 ®...
Electrical installation X2011: Motor with brake control X2011: Motor with brake control NOTICE Damage or malfunction due to motors with built-in brake rectifiers. Damage to the drive system or its environment. • Do not use motors with built-in brake rectifiers in conjunction with this device. Function Power connection for motor with brake up to 4 kW Connection type...
Page 32
Electrical installation X2011: Motor with brake control 4.4.1 Connection cable 2.2 kW device power IEC Cable Length/installation Type Component type Part number: 18125794 Cable design: 4G1.5 DRN80 – 100 DRL71 – 80 Variable length D/1.5 ® Q 8/0 ↔ open (terminal box connection M4) Part number: 18127703W DRN80 – 100W Cable design: 4G1.5 DRL71 – 80W Variable length D/1.5...
Page 33
Electrical installation X2011: Motor with brake control Cable Length/installation Type Component type Part number: 18127738 Cable design: 4G1.5 DRN80 – 100 DRL71 – 80 Variable length D/1.5 ® Q 8/0 ↔ ASB8 Part number: 18125859 Cable design: 4G1.5 CMP63 – 80 Variable length E/1.5 ®...
Page 34
Electrical installation X2011: Motor with brake control Cable Length/installation Type Component type Part number: 18144284m DRN80 – 100m Cable design: 4G2.5 DRL71 – 80m Variable length D/2.5 ® Q 8/0 ↔ IS m Part number: 18174442 Cable design: 4G2.5 DRN80 – 100 DRL71 – 80 Variable length D/2.5 ®...
Page 35
Electrical installation X2011: Motor with brake control Conductor assignment Part number Signal name Color coding Black/U1 Black/V1 Black/W1 Black/1 18125794 Black/2 18143776 Black/3 Black/4 Black/5 PE connection Green-yellow + shield end (Inner shield) Connecting the hybrid cable The following figure shows the connection of the hybrid cable to the terminal box of the motor.
Page 36
Electrical installation X2011: Motor with brake control Adapter cable 2.2 kW device power IEC/UL Cable Length/installation Type Component type Part number: 18161243 Cable design: 4G2.5 All connection cables ® with Han 6B Variable length D/2.5 Note the motor assign- ments to the device (only 2.2 kW).
Electrical installation X2012: Motor with brake control X2012: Motor with brake control NOTICE Damage or malfunction due to motors with built-in brake rectifiers. Damage to the drive system or its environment. • Do not use motors with built-in brake rectifiers in conjunction with this device. Function Power connection for motor with brake up to 7.5 kW Connection type...
Page 38
Electrical installation X2012: Motor with brake control 4.5.1 Connection cable 4 kW device power IEC Cable Length/installation Type Component type Part number: 18118135 Cable design: 4G1.5 DRN80 – 100 DRL71 – 100 Variable length D/1.5 ® 6 B ↔ open (terminal box connection M4) Part number: 18118143 Cable design: 4G1.5 DRN112 DRL112 – 132 Variable length...
Page 39
Electrical installation X2012: Motor with brake control Cable Length/installation Type Component type Part number: 18118186 Cable design: 4G1.5 DRN80 – 112 DRL71 – 132 Variable length D/1.5 ® 6 B ↔ ABB8 Part number: 18118194 Cable design: 4G1.5 DRN80 – 112 DRL71 – 132 Variable length D/1.5 ® 6 B ↔ ASB8 Part number: 18122027 Cable design: 4G1.5 CMP63 –...
Page 40
Electrical installation X2012: Motor with brake control 4 kW device power UL Cable Length/installation Type Component type Part number: 18108334 Cable design: 4G2.5 DRN80 – 100 DRL71 – 100 Variable length D/2.5 ® 6 B ↔ open (terminal box connection M4) Part number: 18108342 Cable design: 4G2.5 DRN112 DRL112 – 132 Variable length D/2.5...
Page 41
Electrical installation X2012: Motor with brake control Cable Length/installation Type Component type Part number: 18108202 Cable design: 4G2.5 DRN80 – 112 DRL71 – 100 Variable length D/2.5 ® 6 B ↔ ASB8 Part number: 18110525 Cable design: 4G2.5 CMP63 – 80 Variable length E/2.5 ® 6 B ↔ SB12 7.5 kW device power IEC Cable Length/installation Type...
Page 42
Electrical installation X2012: Motor with brake control Cable Length/installation Type Component type Part number: 18108318 m DRN80 – 112 m Cable design: 4G2.5 DRL71 – 100 m Variable length D/2.5 ® 6 B ↔ IS m Part number: 18108326 W DRN80 – 112 W Cable design: 4G2.5 DRL71 – 100 W Variable length D/2.5 ® 6 B ↔ IS W Part number: 18108202 Cable design: 4G2.5 DRN80 – 112 DRL71 – 100...
Page 43
Electrical installation X2012: Motor with brake control 7.5 kW device power UL Cable Length/installation Type Component type Part number: 18120601 Cable design: 4G4 DRN112 – 132 DRL112 – 132 Variable length D/4.0 ® 6 B ↔ open (terminal box connection M5) Part number: 18120628 Cable design: 4G4 DRN80 – 132 DRL71 – 90 Variable length...
Page 44
Electrical installation X2012: Motor with brake control Cable Length/installation Type Component type Part number: 18122035 Cable design: 4G4 CMP63 – 100 Variable length E/4.0 ® 6 B ↔ SB14 Conductor assignment Part number Motor termi- Color coding Hybrid cable Connection nal DR.. mo- designation device Black...
Page 45
Electrical installation X2012: Motor with brake control Connecting the hybrid cable The following figure shows the connection of the hybrid cable to the terminal box of the motor. Also observe the wiring diagram of the respective motor. GNYE BK/W1 BK/V1 BK/U1 BK/3 BK/1...
Page 46
Electrical installation X2012: Motor with brake control 7.5 kW device power IEC/UL Cable Length/installation Type Component type Part number: 18157475 Cable design: 4G6 Variable length Connection cable: Mo- D/6.0 ® tor cable with Han 6B ® ® 6 B ↔ Han 6 B Phase reversal cable INFORMATION If you are using an encoder, note that you also need an encoder signal reversal cable in addition to the phase reversal cable.
Page 47
Electrical installation X2012: Motor with brake control 7.5 kW device power UL Cable Length/installation Type Wiring diagram type Part number: 18122000 U1 – V1 Cable design: 4G6 V1 – U1 W1 – W1 Fixed length 13 – 13 D/6.0 14 – 14 15 – 15 TF+ – TF+ ® ® 6 B ↔ Han 6 B TF- – TF- ® Revision –...
Electrical installation X2016: Motor with brake control X2016: Motor with brake control NOTICE Damage or malfunction due to motors with built-in brake rectifiers. Damage to the drive system or its environment. • Do not use motors with built-in brake rectifiers in conjunction with this device. Function Power connection for motor with brake up to 22 kW Connection type...
Page 49
Electrical installation X2016: Motor with brake control 4.6.1 Connection cables 11 kW device power IEC Cable Length/installation Type Component type Part number: 18110452 Cable design: 4G6 DRN112 – 132 DRL112 – 132 Variable length D/6.0 ® 10 B ↔ open (terminal box connection M5) Part number: 18110479 Cable design: 4G6 DRN160 DRL160...
Page 50
Electrical installation X2016: Motor with brake control Cable Length/installation Type Component type Part number: 18120652 Cable design: 4G4 DRN112 – 160 DRL112 – 132 Variable length D/4.0 ® 10 B ↔ ABB8 Part number: 18146252 m DRN80 – 132m Cable design: 4G4 DRL71 – 90m Variable length D/4.0 ® 10 B ↔ IS2 m Part number: 18146228 W DRN80 –...
Page 51
Electrical installation X2016: Motor with brake control Cable Length/installation Type Component type Part number: 18110436 Cable design: 4G6 DRN160 DRL160 Variable length D/6.0 ® 10 B ↔ ABB8 Part number: 18110533 Cable design: 4G6 CMP80 – 100 Variable length E/6.0 ® 10 B ↔ SBB6 Part number: 18122051 Cable design: 4G4 CMP63 –...
Page 52
Electrical installation X2016: Motor with brake control Cable Length/installation Type Component type Part number: 18110479 Cable design: 4G6 DRN180 DRL180 Variable length D/6.0 ® 10 B ↔ open (terminal box connection M6) Part number: 18110436 Cable design: 4G6 DRN180 DRL180 Variable length D/6.0 ® 10 B ↔ ABB8 Part number: 18123562W Cable design: 4G6...
Page 53
Electrical installation X2016: Motor with brake control 15 kW device power IEC Cable Length/installation Type Component type Part number: 18110452 Cable design: 4G6 DRN180 DRL180 Variable length D/6.0 ® 10 B ↔ open (terminal box connection M5) Part number: 18110479 Cable design: 4G6 DRN180 DRL180 Variable length D/6.0 ®...
Page 54
Electrical installation X2016: Motor with brake control Cable Length/installation Type Component type Part number: 18110533 Cable design: 4G6 CMP80 – 100 Variable length E/6.0 ® 10 B ↔ SBB6 15 kW device power UL Cable Length/installation Type Component type Part number: 18121985 Cable design: 4G10 DRN180 DRL180 Variable length D/10.0...
Page 55
Electrical installation X2016: Motor with brake control Cable Length/installation Type Component type Part number: 18182151 Cable design: 4G10.0 CMP80 – 112 Variable length D/10 ® 10B ↔ SBB10 22 kW device power IEC Cable Length/installation Type Component type Part number: 18121985 Cable design: 4G10 DRN180 DRL180 Variable length D/10.0...
Page 56
Electrical installation X2016: Motor with brake control Cable Length/installation Type Component type Part number: 18182151 Cable design: 4G10.0 CMP80 – 112 Variable length D/10 ® 10B ↔ SBB10 Conductor assignment Part number Motor termi- Color coding Hybrid cable Connection nal DR.. mo- designation device Black Motor phase U Black...
Page 57
Electrical installation X2016: Motor with brake control Connecting the hybrid cable The following figure shows the connection of the hybrid cable to the terminal box of the motor. Also observe the wiring diagram of the respective motor. GNYE BK/W1 BK/V1 BK/U1 BK/3 BK/1...
Page 58
Electrical installation X2016: Motor with brake control 15 kW device power IEC Cable Length/installation Type Component type Part number: 18164226 Cable design: 4G6 Connection cable: Mo- Variable length D/6.0 tor cable with ® 10 B ® ® 10 B ↔ Han 10 B Phase reversal cable INFORMATION If you are using an encoder, note that you also need an encoder signal reversal cable in addition to the phase reversal cable.
Page 59
Electrical installation X2016: Motor with brake control 22 kW device power IEC Cable Length/installation Type Wiring diagram type Part number: 18113745 U1 – V1 Cable design: 4G10 V1 – U1 W1 – W1 Fixed length 13 – 13 D/10.0 14 – 14 15 –...
Startup With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) Startup With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) 5.1.1 Startup procedure The following step-by-step instructions give an overview of the device startup proce- dure and lists other applicable documentation: 1. Install the motor. Refer to the operating instructions of the motor for more informa- tion.
Page 61
Startup With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) The following figure shows the position of the DIP switches on the system bus module: 9007215129149451 [1] DIP switch for setting the baud rate [5] Knurled screw [2] DIP switch for setting the slave device number [6] System bus output [3] Not connected [7] System bus input...
Page 62
Startup With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) Setting the baud rate Use the S1 DIP switch to set the baud rate: External SBus baud rate S1/1 S1/2 SBus baud rate 125 kBaud SBus baud rate 250 kBaud SBus baud rate 500 kBaud SBus baud rate 1000 kBaud Setting the slave device number Use the S2 DIP switch to set the slave device number.
Page 63
Startup With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) 5.1.3 PC/laptop connection The following figure shows the connection between a PC/laptop and the Ethernet ser- vice interface of the device: 21895030155 Master unit Ethernet service interface (Ethernet RJ45) of master device Commercially available Ethernet cable Ethernet interface of the laptop Slave unit...
Page 64
Startup With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) 5.1.4 SBus addresses of the power sections in the slave controller From the master controller's viewpoint, the SBus addresses of the components are di- vided depending on the setting of the S2 DIP switch for the devices. The following chart depicts how each SBus address is divided for the respective slave device num- ber: Internal...
Operation With device type PHC2.A‑A...M1-..1A-00/... Operation With device type PHC2.A‑A...M1-..1A-00/... 6.1.1 Status and error messages If you use a parameterizable device, the following status messages are possible. Code Meaning Measure A1.0 DC 24 V operation, frequency in- verter not ready A1.1 Controller inhibit active A1.2 No enable...
Page 66
Operation With device type PHC2.A‑A...M1-..1A-00/... Code Meaning Measure BUS ERR Fault • Check the fieldbus wiring to the higher-level controller. • Fault in fieldbus parameters • Check the fieldbus parameter or fieldbus stations incorrectly setting of the device and the higher-level controller.
Page 67
Operation With device type PHC2.A‑A...M1-..1A-00/... Code Meaning Measure Fault Communication error with the power section, caused by e.g.: • Parameter channel 2 not acti- • Activate parameter channel 2. vated (P889) • Manual operation not finished • Activate manual operation. Deactivate it afterwards.
Page 68
Operation With device type PHC2.A‑A...M1-..1A-00/... Code Meaning Measure SF22 Warning • Start the data management again. • Error during data manage- ment, data recovery to device failed SF23 Warning Set the device to one of the fol- lowing states: • Error during data recovery to device, controller inhibit not •...
Page 69
Operation With device type PHC2.A‑A...M1-..1A-00/... Code Meaning Measure • The bootloader update is be- • Do not switch off the device. ing executed. • Wait until the bootloader up- date has been completed. If the device does not respond as expected after 5 minutes, proceed as described in chapter "SD memory card as spare part" (→ 2 74).
Page 70
Operation With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) 6.2.1 Status and error messages The device’s status display shows the current operating status. There are two kinds of status and error messages: from the device and from the user program. Status and error messages from the device are issued when no user program is active.
Page 71
Operation With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) Code Possible cause Measure SF 200 • There is an internal system • Restart the slave device. error. Check whether the slave device starts correctly. • If the status message is dis- played repeatedly, contact SEW‑EURODRIVE Service.
Service With device type PHC2.A‑A...M1-..1A-00/... Service With device type PHC2.A‑A...M1-..1A-00/... 7.1.1 Device replacement The device allows for a quick device replacement. It is equipped with a replaceable SD memory card on which all device data is stored. If the device has to be replaced, the plant can be started up again quickly by simply exchanging the SD memory card.
Page 73
Service With device type PHC2.A‑A...M1-..1A-00/... 7-segment display: Status LED S2: Flashes green/orange Data backup of the communication and control unit is restored. This process can take several minutes. Do not switch off the device during this time. > 5 minutes Chapter Wrong bootloader software "SD memory card as...
Page 74
Service With device type PHC2.A‑A...M1-..1A-00/... SD memory card as spare part If you have ordered an SD card as spare part, it is possible that the versions of the bootloader software are different for the SD memory card and your device. In this case, the device remains in the following state for more than 5 minutes: 7-segment display Status LED S2...
Service With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) With device type PHC2.A‑A...M1-Z14A-00/... (SBus slave controller) 7.2.1 Device replacement The device allows for a quick device replacement. If the device has to be replaced, the plant can be started up again quickly by simply exchanging all plug-in contacts. For successful startup after device replacement, you must configure the S1 DIP switch and the S2 DIP switch on the slave controller's system bus module.
Technical data Communication unit Technical data Communication unit 8.1.1 Slave controller control type External SBus interface Bus system CAN (specification 2.0, parts A and B) ® Protocol variant MOVILINK via SBus Supported baud rates Configurable via S1 DIP switch 125 kBaud 250 kBaud 500 kBaud 1000 kBaud...
Declaration of conformity Declaration of conformity EU Declaration of Conformity Translation of the original text 901500116/EN SEW-EURODRIVE GmbH & Co. KG Ernst-Blickle-Straße 42, D-76646 Bruchsal declares under sole responsibility that the following products ® Drive systems of the product family MOVIPRO SDC PHC2.A-A...M1-..0A-00/...
Page 80
SEW-EURODRIVE—Driving the world SEW-EURODRIVE GmbH & Co KG Ernst-Blickle-Str. 42 76646 BRUCHSAL GERMANY Tel. +49 7251 75-0 Fax +49 7251 75-1970 [email protected] www.sew-eurodrive.com...