Haier HSU-12LNA/022L(W) Operational Manual

Split type on-off room air conditioner
loading

Summary of Contents for Haier HSU-12LNA/022L(W)

  • Page 2 Haier Customer Services Center Haier Customer Services Center Haier Customer Services Center House No. 34-G C-16, Block # 5, Rashid Minhas Road, Banglow # A/41, Block-A, Unit # 9, Gulberg-III (Firdous Market). Nr. NIPA Chorangi. Mir Faza Town, Latifabad. Lahore - I...
  • Page 3 Dear Valued Customer, We congratulate and thank you for your trustworthy selection of Haier Air Conditioner. Haier the manufacturer of quality products, feel very proud while delivering reliable, durable and energy saving home appliances in accordance with the rapid growing living standards of Pakistan.
  • Page 4: Table Of Contents

    Cautions Table of Contents Safety Instructions and warnings PAGE Before starting the air conditioner, read the information giving in the User's Cautions Guide carefully. The user's Guide contains very important observations Parts & Functions 4-5-7-9 relating to the assembly, operation and maintenance of the air conditioner.
  • Page 5 Parts and Function Cautions surfaces. If the refrigerant spurts out and gets into eyes, it may result in Indoor Unit serious eye injuries. Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things Test running switch(manual) into the inlet/outlet and swing louver.
  • Page 6: Specifications

    6.8 A Rated Current 9.1 A UAN : 042-1111-42437 UAN : 042-1111-42437 For your best opinion or For your best opinion or e-mail : [email protected] e-mail : [email protected] any complain, please dial any complain, please dial Customer Care Customer Care INLET...
  • Page 7 Parts and Function Parts and Function Operation Buttons and display of the remote controller. Power ON/OFF LO, MED, HI, AUTO TEMP HEALTH TURBO/QUIET POWER ON/OFF TURBO/QUIET MODE SWING COOL COOL AUTO RUN, COOL, DRY, HEAT and FAN Operation TEMP TEMP HOUR SWING LEFT/RIGHT AIR FLOW...
  • Page 8: Operation

    Operation Parts and Function Operation Buttons and display of the remote controller. Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. COOL The distance between the signal transmission HEAT head and the receive hole should be within 7m without any obstacle as well.
  • Page 9 Operation Operation Load the battery Auto run, Fan operation Enjoy yourself by just a gentle press. Be sure while loading the batteries that these are in line the "+"/"-" pole request (1) Unit start as illustrated. Press ON/OFF button, unit starts. Previous operation status appears on display.
  • Page 10 Operation Operation (4) Unit Stop Cool, Heat and Dry operation Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. Vertical flap closed Recommendations: Use Cool in summer Use Heat in winter automatically. Use Dry in spring, autumn and in damp climate Hints (1) Unit start Remote controller can memorize settings in each operation mode.
  • Page 11 Operation Operation (3) Fan Speed selection (5) Air flow direction adjustment Press FAN button, For each press, fan speed changes as follows: After operation mode is selected vertical flap will open automatically according to the mode. Referring to the fig. COOL operation starts when room AUTO temp is higher than temp setting...
  • Page 12 Operation Operation (6) Unit stop TIMER Operation Press ON/OFF button. Only time remains on LCD. All indicators on indoor unit go out. Set CLOCK Correctly before starting Timer Vertical flap closes automatically. operation (referring to page 6) you can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall...
  • Page 13 Operation Operation (4) Confirming your setting Airflow Position After setting correct time, press SET button to confirm, "ON" or "OFF" stop After unit start flashing. (1) Select your desired operation mode Time displayed: Unit starts or stops at with "MODE BUTTON". x hour x min.
  • Page 14 Operation Operation Test operation: Emergency operation and test operation CUse this switch in the test operation when the room temperature is less 16 C, do not use it in the normal operation. Emergency operation: Continue to press the test operation switch for more Carry out this operation only when the remote controller then 5 seconds.
  • Page 15 Operation Operation Update Sleep mode Press sleep button ten times with in 5 sec if you will hear 4 times (pi) sound then it is activated and if you hear 2 times (pi) sound then sleep mode is deactivated. Power Failure Resume Function Only some of the models have this function.
  • Page 16: Installation

    Installation Installation Selection of Installation Place Power Source Indoor, Outdoor Unit Selection of pipe Description 12 LT 12 LNF 18 LT 18 LNF 24 LT 12 HT 18 HT 24 HT Liquid Pipe ( ) 6.35mm 6.35mm 6.35mm 6.35mm 9.52mm 6.35mm 6.35mm 9.52mm...
  • Page 17 Installation Installation Drawing for the installation of indoor and outdoor unit...
  • Page 18 Installation Installation Indoor Unit Push the button of unlock from left and right side as shown in picture, then push it out of socket and take out the inlet grill.
  • Page 19 Installation Installation Connecting the indoor/outdoor Electric Cable...
  • Page 20 Installation Installation Outdoor Unit...
  • Page 21 Installation Installation When connecting pipe exceeds 16.4 feet, 6g refrigerant shall be added per exceeding feet. Charge according to the following list. 16.4ft. 23ft. 33ft.
  • Page 22 Maintenance Maintenance * Different models have different appearance. Cleaning of air filter. Cleaning of unit casing 1. Open inlet grill by pulling 2. Remove air filter it upward. Push up the filter's center tab slightly until it is caesure of the stopper.
  • Page 23: Maintenance

    Maintenance Maintenance Replacement of Electrostatic Filter Better use of air conditioner Detach the Air Filters. Proper room temperature Cleaning of the air filter Proper Detach the Electrostatic Filters. Once every temperature two weeks Be careful with fins. Closing of doors and windows Effective use of the timer during operation Replace the old filter with...
  • Page 24: Trouble Shooting

    Trouble Shooting Trouble Shooting Please check the instructions before service. Phenomenon Cause or check points Phenomenon Cause or check points Does not work at all Is power plug inserted? Is there a power failure? The system does not When unit is stopped, it won's restart Is fuse blown out? restart immediately.