Omron S8FS-G Series Manual

Omron S8FS-G Series Manual

Switch mode power supply
Hide thumbs Also See for S8FS-G Series:
New Product
Switch Mode Power Supply
S8FS-G (15/30/50/100/150/300/600-W Models)
Superior Performance and
Reliability, Meets a Wide Range
of Standards, Allowing Great
Usability.
• Superior basic performance that ensures reliability
Ambient temperatures up to 70°C, greater
resistance to rusting with aluminum/stainless steel
case, and applications at altitudes up to 3,000 m.
• Certification for Global Standards
North America: UL 508 (Listing)*, CSA C22.2
Europe: Overvoltage Category III (EN 50178)
EMI: Class B (EN 61204-3)
No need for control circuit transformers for which the
Machinery Directive is specified. (IEC 61558-2-16)
* Refer to pages 4 to 10 for certified models.
• Conforms to SEMI F47-0706 (200 VAC input).
• Great Usability
The Terminal Block Cover prevents screws from
dropping out and the Front Cover prevents
ingress of foreign matter.
Lineup
Output voltage
5 V
12 V
15 V
24 V
48 V
Model Number Structure
Model Number Legend
Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below.
S8FS- G@@@ @@ @ @-@ @
1
2
3
1. Power Ratings
2. Output voltage
015: 15 W
05: 5 V
030: 30 W
12: 12 V
050: 50 W
15: 15 V
100: 100 W
24: 24 V
150: 150 W
48: 48 V
300: 300 W
600: 600 W
*1. Applicable only for 600 W and 24 V.
*2. Applicable only for 100 W or more and 24 V.
15 W
30 W
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
---
---
4
5
6
3. Configuration
C:
With cover/Direct mounting
CD: With cover/DIN Rail mounting
4. Option (1)
None: Screw terminal block
! Refer to Safety Precautions for All Power Supplies and Safety
Precautions on page 26.
Power rating
50 W
100 W
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
---
---
5. Option (2) *1
6. Option (3) *2
150 W
300 W
Yes
---
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
None: None
W:
Parallel operation
None: None
R:
Remote control
600 W
---
Yes
Yes
Yes
Yes
1
Table of Contents
loading

Summary of Contents for Omron S8FS-G Series

  • Page 1 New Product Switch Mode Power Supply S8FS-G (15/30/50/100/150/300/600-W Models) Superior Performance and Reliability, Meets a Wide Range of Standards, Allowing Great Usability. • Superior basic performance that ensures reliability Ambient temperatures up to 70°C, greater resistance to rusting with aluminum/stainless steel case, and applications at altitudes up to 3,000 m.
  • Page 2 S8FS-G Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. With Cover/Direct Mounting Power ratings Input voltage Output voltage (VDC) Output current Built-in fan Model S8FS-G01505C 12 V 1.3 A S8FS-G01512C 15 W...
  • Page 3 24 V 14 A S8FS-G30024CD 48 V S8FS-G30048CD 12 V 50 A S8FS-G60012CD 15 V 40 A S8FS-G60015CD 600 W 24 V 27 A S8FS-G60024CD 48 V 13 A S8FS-G60048CD Note: Ask your OMRON representative for pricing information on optional models.
  • Page 4: Specifications

    S8FS-G Specifications Power rating 15 W Item Output voltage 12 V 15 V 24 V 80% typ. 84% typ. 84% typ. 85% typ. 100 VAC input Efficiency * 80% typ. 84% typ. 84% typ. 86% typ. 200 VAC input 80% typ. 84% typ.
  • Page 5 S8FS-G Power rating 30 W Item Output voltage 12 V 15 V 24 V 81% typ. 84% typ. 86% typ. 86% typ. 100 VAC input Efficiency * 81% typ. 86% typ. 88% typ. 88% typ. 200 VAC input 81% typ. 86% typ.
  • Page 6 S8FS-G Power rating 50 W Item Output voltage 12 V 15 V 24 V 81% typ. 84% typ. 86% typ. 86% typ. 100 VAC input Efficiency * 82% typ. 86% typ. 88% typ. 89% typ. 200 VAC input 82% typ. 86% typ.
  • Page 7 S8FS-G Power rating 100 W Item Output voltage 12 V 15 V 24 V 79% typ. 84% typ. 85% typ. 87% typ. 100 VAC input Efficiency * 81% typ. 86% typ. 87% typ. 89% typ. 200 VAC input 81% typ. 86% typ.
  • Page 8 S8FS-G Power rating 150 W Item Output voltage 12 V 15 V 24 V 48 V 78% typ. 84% typ. 85% typ. 87% typ. 85% typ. 100 VAC input Efficiency *1 81% typ. 87% typ. 88% typ. 89% typ. 88% typ. 200 VAC input 81% typ.
  • Page 9 S8FS-G Power rating 300 W Item Output voltage 12 V 15 V 24 V 48 V 81% typ. 81% typ. 82% typ. 82% typ. 100 VAC input Efficiency * 85% typ. 85% typ. 87% typ. 87% typ. 200 VAC input 85% typ.
  • Page 10 S8FS-G Power rating 600 W Item Output voltage 12 V 15 V 24 V 48 V 84% typ. 84% typ. 85% typ. 88% typ. 100 VAC input Efficiency * 88% typ. 88% typ. 89% typ. 92% typ. 200 VAC input 88% typ.
  • Page 11 S8FS-G Ratings, Characteristics, and Functions The value is when both rated output voltage and rated output current are satisfied. Efficiency Do not use an inverter output for the Power Supply. Inverters with an output frequency of Voltage range 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may Frequency result in ignition or burning.
  • Page 12 S8FS-G Connections Block Diagrams S8FS-G015@@@ (15 W) S8FS-G030@@@ (30 W) S8FS-G050@@@ (50 W) AC(L) Fuse 250 VAC DC OUTPUT Noise filter 15/30 W: 3.15 A INPUT 50 W: 4 A Inrush current Rectifier Smoothing Rectifier AC(N) protection circuit smoothing circuit Control circuit Over current...
  • Page 13 S8FS-G S8FS-G300@@@ (300 W) AC(L) Fuse Noise 250 VAC DC OUTPUT filter INPUT 12 A Rectifier Inrush Harmonic current Smoothing Rectifier AC(N) suppression current circuit smoothing circuit (power factor protection improvement) Drive circuit Over current detection Rectifier Control circuit smoothing circuit circuit Voltage detection circuit...
  • Page 14 S8FS-G Construction and Nomenclature Nomenclature S8FS-G015@@@ S8FS-G100@@@ S8FS-G300@@@ S8FS-G030@@@ S8FS-G150@@@ S8FS-G600@@@ S8FS-G050@@@ S8FS-G@@@24C-R S8FS-G@@@24C-WR (12) (11) (10) (11) (10) Terminal name Name Function Input terminals Connect the input lines to these terminals. *1 Protective Earth terminal Connect the ground line to this terminal. *2 DC output terminals Connect the load lines to these terminals.
  • Page 15: Engineering Data

    S8FS-G Engineering Data Derating Curves Output Derating 15 W, 30 W, 50 W, 300 W, and 600 W 100 W and 150 W -30 -20 -10 -30 -20 -10 Ambient Temperature (°C) Ambient Temperature (°C) Note: At less than 100 VAC, derate the load at 1.3%/V. Note: At less than 100 VAC, derate the load at 1.3%/V.
  • Page 16 S8FS-G This Power Supply can be used at an altitude of 3,000 m. Between 2,000 and 3,000 m, derate the load according to the following derating curve. 15 W, 30 W and 50 W 100 W and 150 W 45 °C max. 35 °C max.
  • Page 17: Overload Protection

    S8FS-G Engineering Data Overload Protection Remote Control Function (Only Remote control) The load and the Power Supply are automatically protected from This function is to turn ON/OFF the output by applying a voltage to the overcurrent damage by this function. Overload protection is activated remote control connector from a DC power Supply (external power if the output current rises above 105 to 160% of the rated current.
  • Page 18 S8FS-G Dimensions (Unit: mm) Power Supplies 15 W and 30 W S8FS-G015@@C S8FS-G030@@C (14.3) 20.5 Panel mounting holes dimensions ±0.5 Using the screw Using the mounting holes holes in the in the Power Supply Power Supply ±1 Two, 3.5 dia. Side ±0.5 Two, M3...
  • Page 19 S8FS-G S8FS-G050@@C (14.3) 20.5 ±0.5 Panel mounting holes dimensions Using the screw Using the mounting holes holes in the in the Power Supply Power Supply ±1 Two, 3.5 dia. Side 55.5 ±0.5 55.5 ±0.5 Two, M3 Mounting Two, M3 ±0.5 (Depth 5 mm max.) 45.5 ±0.5...
  • Page 20 S8FS-G 100W S8FS-G100@@C (14.3) Two, M3 (Depth 5 mm max.) 85.5 ±0.5 ±0.5 ±1 3.5 dia. 122.5 Seven, M3.5 ±0.5 5.25 ±1 ±0.5 Three, M3 (Depth 6 mm max.) 3.5 dia. ±0.5 ±1 ±0.5 28.5 28.5 ±0.5 Panel mounting holes dimensions Using the mounting holes in the Using the screw holes Power Supply...
  • Page 21 S8FS-G 150W S8FS-G150@@C (14.3) ±0.5 84.5 ±0.5 Two, M3 (Depth 5 mm max.) ±1 3.5 dia. 152.5 Seven, M3.5 ±0.5 ±1 Three, M3 (Depth 6 mm max.) ±0.5 3.5 dia. ±0.5 ±0.5 ±1 28.5 28.5 10.5 ±0.5 Panel mounting holes dimensions Using the mounting holes in the Using the screw holes in the Power Supply...
  • Page 22 S8FS-G 300W S8FS-G300@@C Two, M4 (Depth 5 mm max.) 28.5 ±0.5 Panel mounting holes dimensions Using the screw holes in the Power Supply Two, 4.5 dia. Side ±1 Mounting ±0.5 Four, 4.5 dia. 50.5 Bottom Mounting ±0.5 ±0.5 (14.1) Seven, M3.5 (3.5) ±1 ±0.5...
  • Page 23 S8FS-G 600W S8FS-G600@@C Four, M4 (Depth 5 mm max.) Four, M4 20.5 11 ±0.5 ±1 Three, M3.5 ±0.5 (3.7) (16.1) ±1 ±0.5 ±1 12.5 ±0.5 (14.1) Four, M4 (Depth 5 mm max.) Panel mounting holes dimensions Using the screw holes in the Power Supply Four, 4.5 dia.
  • Page 24 S8FS-G Mounting Brackets (Order Separately) Use the Front-mounting Brackets together with DIN Rail-mounting Power Supplies (S8FS-G@@@@@CD). Power rating Mounting direction Model 15 W, 30 W, 50 W Front-mounting S82Y-FSG-30F 100 W, 150 W and 300 W 600 W Front-mounting S82Y-FSG-60F S82Y-FSG-30F Two, ±0.1...
  • Page 25: End Plate

    S8FS-G DIN Rail (Order Separately) (Unit: mm) Mounting Rail (Material: Aluminum) PFP-100N PFP-50N 7.3 ± 0.15 35 ± 27 ± 0.15 15(5) * 1,000 (500) * * Values in parentheses are for the PFP-50N. Mounting Rail (Material: Aluminum) PFP-100N2 35 ± 29.2 1,000 End Plate...
  • Page 26: Safety Precautions

    S8FS-G Safety Precautions Refer to Safety Precautions for All Power Supplies. Warning Indications Precautions for Safe Use Indicates a potentially hazardous Ambient Operating and Storage Environments situation which, if not avoided, may CAUTION • Store the Power Supply at a temperature of −25 to 75°C and a result in minor or moderate injury or in humidity of 90% max.
  • Page 27: Overcurrent Protection

    S8FS-G • Use the following material for the wires to be connected to the Mounting S8FS-G to prevent smoking or ignition caused by abnormal loads. S8FS-G015@@@ to 150@@@ 20 mm min. 20 mm min. Terminals and Wiring (Screw terminal block type) Recommendes Terminals Model...
  • Page 28: Series Operation

    S8FS-G Output Voltage Adjuster (V. ADJ) Parallel Operation • The output voltage adjuster (V. ADJ) may possibly be damaged if Parallel operation is used when the output current from one Power it is turned with unnecessary force. Do not turn the adjuster with Supply is insufficient for the load.
  • Page 29: Backup Operation

    (OFF). Check the following five points. If there is still no output voltage, contact your OMRON representative. • Checking Overload Protection: Remove the load wires and check whether the load is in an overload state or is short-circuited.
  • Page 30 Note: The maximum ratings must be within the derating curve. If the Power Supply fails for reasons attributable to OMRON within the above warranty period, OMRON will repair or replace the faulty part of the Power Supply at the place of purchase or the place where the Power Supply delivered without charge.
  • Page 31: Terms And Conditions Agreement

    Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements.
  • Page 32 OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. • +31 (0) 23 568 13 00 • www.industrial.omron.eu Authorized Distributor: Controllers & I/O •...

Table of Contents