Rack-mounting the A5120 EI switch in a 19-inch
rack
CAUTION:
Switches with 420 mm (16.54 in) depth require either a rack shelf or rear mounting brackets. Front
mounting brackets alone cannot support the weight of these switches.
Table 6
shows installation methods for mounting switches of different depths in a 19-inch standard rack.
The mounting position depends on the depth of the rack.
Table 6 Installation methods
Chassis
A5120-24G EI (2 slots)
A5120-24G EI TAA (2 slots)
A5120-48G EI (2 slots)
A5120-48G EI TAA (2 slots)
A5120-24G EI
A5120-48G EI
A5120-24G-PoE+ EI (2 slots)
A5120-24G-PoE+ EI TAA (2
slots)
A5120-48G-PoE+ EI (2 slots)
A5120-48G-PoE+ EI TAA (2
slots)
Mounting brackets
NOTE:
The M6 screws for fastening the brackets to a rack are user-supplied.
Use front
mounting
Depth
brackets
only
Yes (see
"Rack-
300 mm
mounting
(11.81
using only
in)
front
mounting
brackets"
420 mm
(16.54
No
in)
5
Use front mounting
brackets and a rack
shelf
Yes (see
"Rack-
mounting using front
mounting brackets and
a rack
shelf")
Yes (see
"Rack-
mounting using front
mounting brackets and
a rack
shelf")
Use front and
rear mounting
brackets
No
Yes (see
"Rack-
mounting by
using front and
rear mounting
brackets")