A - Screw Driver Small Flat B - Screw Driver Phillips #2 C - Screw Driver Torx T-20 D - Hexagonal Key 3 mm E - 5/16" / 7/16" / 1" Drill Bit F - Needle Nose Pliers Confidant RFID Exit Device Operators PK3664-T 04-17...
2- Inventory Exit Device Operator Hardware Bag Double Enclosure Confidant RFID with battery holder Drilling Template NOTES: 1- FOR DIMENSIONS AND TOLERANCES REFER TO: DOOR PREPARATION DRAWING CORRESPONDING IP #. 2- FOR EXIT DEVICE AND MORTISE LOCK CUT-OUT 3-15/32 REFER TO EXIT DEVICE MANUFACTURER [88,5] INSTALLATION INSTRUCTIONS.
These instructions are designed for use by maintenance professionals or lock installers who are familiar with common safety practices and competent to perform the steps described. dormakaba is not responsible for damage or malfunction due to incorrect installation, that may arise.
5- Attach and clamp spindle clip to spindle as shown Ensure legs are firmly clamped against the spindle For the spindle position, see the table in the document named "spindle position" Confidant RFID Exit Device Operators PK3664-T 04-17...
6- Install outside lever Left Hand WARNING CAUTION IMPORTANT Hold down the outside lever against the outside housing while tightening the lever set screw. Right Hand Confidant RFID Exit Device Operators PK3664-T 04-17...
7- Prepare the door for the appropriate exit device DRILLING TEMPLATE BACKSET 8- Install the mortise (If applicable) For mortise exit devices, install the mortise according to the manufacturer's instructions. 9- Install lock on door Confidant RFID Exit Device Operators PK3664-T 04-17...
G Attach the base (S-base) to the adpator plate (G) with the two screws. Put the cover (S-cover) as shown, and put the screw (S-screw). H Follow the manufacturer’s instructions to complete the installation of the exit device and the appropriate strike Confidant RFID Exit Device Operators PK3664-T 04-17...
Page 10
(Bluetooth and/or Messenger Version) (Suite) ANTENNA BLE ANTENNA MODULE POSITION MESSENGER ANTENNA MESSENGER ANTENNA POSITION MODULE ANTENNA POSITION BLE ANTENNA POSITION EXIT DEVICE EXIT DEVICE SURFACE MOUNT RIM, MORTISE, VERTICALE ROD CONCEALED ROD Confidant RFID Exit Device Operators PK3664-T 04-17...
C - Rotate Outside Lever to Check Bolt or Rod Retraction D - Release Outside Lever, Should Move Freely E - Activate Panic Bar to Check Bolt or Rod Retraction 13- Program lock - With Jack Cable Confidant RFID Exit Device Operators PK3664-T 04-17...
For security reasons, lock must be programmed BEFORE installing the battery door. Every time the battery door is removed pass an emergency card or connect lock to a dormakaba Programming Unit to reset the tamper alarm. Audit information is not affected.
Annex A • Install outside housing with gasket (Exterior and ocean front versions) Annex B • Remove battery holder Unscrew Remove Door Unclip Battery Holder Remove Battery Holder Confidant RFID Exit Device Operators PK3664-T 04-17...
Page 14
Customer Services & Support Ilco: 1.877.468.3555 / + 1.514.340.9025 Saflok: 1.800.999.6213 / + 1.248.837.3700 General information: www.kabalodging.com Online consumable orders: www.ilcostore.com www.saflokstore.com To access all of our easy steps, please visit our support website: www.kabalodgingsupport.com www.dormakaba.com...