Warnings - Cisco 1552S Installation Manual

Hazardous locations
Table of Contents
Additional Considerations for Hazardous Locations
The access point hazardous location option complies with safety standards for Class I, Division 2/Zone
2 hazardous locations where ignitable concentrations of flammable gases, vapors, or liquids are not
likely to exist under normal operation conditions.
When you select the hazardous location option as part of the ordering process, Cisco configures the
system to contain the new components. Assembly instructions placed in the shipping box provide
information and assembly procedures. The hazardous location option configures the access point as
follows:
Caution
Caution
Caution

Warnings

Do not disconnect connections to this equipment unless power has been removed or you have verified
Warning
that the area is nonhazardous. Secure any external connections that mate to this equipment by using
screws, sliding latches, threaded connectors, or other means provided with this product. Substitution
of components may impair suitability for Class I, Zone 2, Division 2. Statement 1062
When used in a Class I, Zone 2, Division 2 hazardous location, this equipment must be mounted with
Warning
a proper wiring method that complies with the governing electrical codes. Statement 1069
Warning
If you connect or disconnect the console cable with power applied to the unit or any device on the
network, an electrical arc can occur. This could cause an explosion in hazardous location
installations. Be sure that power is removed or the area is nonhazardous before proceeding.
To verify unit operation, perform POST on the device in a nonhazardous location before installation.
Statement 1080
Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
2-36
Do not install a battery in a Hazardous Location environment. Battery packs are not approved for
Hazardous Locations.
The AC power connections are moved to the inside of the access point by installing an AC entry
board containing a terminal block. To comply with hazardous location requirements, AC power must
be installed through rigid metal conduit to the terminal block.
The electrical rating for hazardous location installations has a lower voltage rating (100-240
VAC, 50/60 Hz, 1A) than a non-hazardous location installation (100-480 VAC).
Do not use 12 VDC input connection in hazardous locations.
Caution: Power injector (AIR-PWRINJ1500-2=) is not certified for installation within
hazardous locations environments.
Chapter 2
Before You Begin