Removal procedure of 18000/24000/36000 btu/h class
Hide thumbs Also See for 2MXS18NMVJU:
Table of Contents

Outdoor Fan / Fan Motor

2. Outdoor Fan / Fan Motor
Warning
Step
1
Remove the drip proof
cover.
2
Disconnect the
connector [S70].
3
Release the fan motor
lead wire from the
groove and the hook.
4
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Drip proof cover
[S70]
Hook
Groove
Fan motor lead wire
Points
(R22283)
[S70]: fan motor
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
(R22284)
Lead wire
(R22285)
Removal Procedure
Si121558EA
Outdoor fan
(R3249)