Summary of Contents for Eaton HMi VU Series

  • Page 1: Table Of Contents

    Instruction Leaflet IL04801003E Effective February 2012 HMi VU Series Instruction Leaflet Contents Description ..........Page Preface........... 1 Safety Precautions......... 1 Installation..........3 Wiring............. 4 Basic Inspection........4 Hardware Features ........ 7 Panel Cut-Out ........15 Specifications ......... 17...
  • Page 2: Preface

    HMi VU Series Instruction Leaflet Preface Safety Precautions Thank you for purchasing Eaton’s HMi VU Carefully note and observe the following series operator interface. This quick start safety precautions when receiving, inspecting, guide will be helpful in the installation, wiring...
  • Page 3 HMiSoft Screen Editor software overheating. is the only software authorized for creation and editing of applications to be run on Wiring Method Eaton’s HMi and HMi VU series hardware.  Observe voltage specifications.  To avoid personal injury and Failure to do so observe this...
  • Page 4: Installation

    HMi VU Series Instruction Leaflet Installation Installation Notes The panel thickness should be 5 mm  or less for proper mounting. Installation Method: Step 3: Step 1: Torque all fasteners to 6.17lb-inch (0.7N-M) Ensure the pre-installed waterproof gasket is Over torque may cause damage to the operator present and properly aligned.
  • Page 5: Wiring

    HMi VU Series Instruction Leaflet Wiring Basic Inspection • Please observe the following wiring notes. Item Content  Periodically inspect the Use shielded twisted-pair cables for  screws of the connection wiring. between the operator Recommended wiring: interface and device.
  • Page 6 HMi VU Series Instruction Leaflet Pin Definition for HMIVU08CUNBE / HMIVU10WCUNBE Communications COM1 Port (Supports Flow Control) Contact HMIVU06CUNB / HMIVU07CUNBE RS-232 COM1 Port (Supports Flow Control) Contact RS-232 Note: Blank = No Connection. COM2 Port (Supports Flow Control) MODE1...
  • Page 7 HMi VU Series Instruction Leaflet COM3 Port MODE1 MODE2 MODE3 RS-232 RS-422 RS-485 TXD+ (RTS+) RXD+ (CTS+) TXD- (RTS-) RXD- (CTS-) Note1: Blank = No Connection. Note2: When COM2 port is used for RS-422 with flow control, COM3 Port pins 1, 4, 6, and 9 are used for the signals, RTS+, CTS+, RTS- and CTS- as shown in brackets.
  • Page 8: Hardware Features

    HMi VU Series Instruction Leaflet Hardware Features HMIVU06CUNB (Front View) Power LED Indicator (Lights in green when power is applied.) Touch Screen / Display EATON CORPORATION www.eaton.com...
  • Page 9 HMi VU Series Instruction Leaflet HMIVU06CUNB (Rear View) Power Input Terminal USB Host (Note1) COM2 and COM3 USB Slave COM1 System Button Battery Cover NOTE 1. Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3.
  • Page 10 HMi VU Series Instruction Leaflet HMIVU07CUNBE (Front View) Power LED Indicator (Lights in green when power is applied.) Touch Screen / Display EATON CORPORATION www.eaton.com...
  • Page 11 HMi VU Series Instruction Leaflet HMIVU07CUNBE (Rear View) Power Input Terminal USB Host (Note1) COM2 and COM3 USB Slave COM1 System Button Battery Cover Ethernet Port Memory Card Slot Audio Output Port NOTE 1. Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3.
  • Page 12 HMi VU Series Instruction Leaflet HMIVU08CUNBE (Front View) : Power LED Indicator Lights in green when power is applied. (Note1) : Operation LED Indicator (Blue) The operation LED indicator blinks in blue when communicating or accessing data : Alarm LED Indicator (Red) The alarm LED indicator blinks in red when one of the alarms is on.
  • Page 13 HMi VU Series Instruction Leaflet HMIVU08CUNBE (Rear View) Power Input Terminal COM3 (Two LED indicate Read or Write status during the communication process.) COM2 (Two LED indicate Read or Write status during the communication process.) COM1 USB Slave Ethernet Port...
  • Page 14 HMi VU Series Instruction Leaflet HMIVU10WCUNBE (Front View) : Power LED Indicator Lights in green when power is applied. (Note1) : Operation LED Indicator (Blue) The operation LED indicator blinks in blue when communicating or accessing data : Alarm LED Indicator (Red) The alarm LED indicator blinks in red when one of the alarms is on.
  • Page 15 HMi VU Series Instruction Leaflet HMIVU10WCUNBE (Rear View) Power Input Terminal COM2 (Two LED indicate Read or Write status during the communication process.) COM3 (Two LED indicate Read or Write status during the communication process.) COM1 USB Slave Ethernet Port...
  • Page 16: Panel Cut-Out

    HMi VU Series Instruction Leaflet Panel Cut-Out HMIVU06CUNB 0.063"(1.6)~0.24"(6) 6.79"(172.4) 7.24"(184) HMIVU07CUNBE 6.79"(172.4) 0.063"(1.6)~0.24"(6) 7.24"(184) HMIVU08CUNBE EATON CORPORATION www.eaton.com...
  • Page 17 HMi VU Series Instruction Leaflet 8.64"(219.4) 8.94"(227.1) 0.063"(1.6)~0.24"(6) HMIVU10WCUNBE 10.29"(261.3) 0.063"(1.6)~0.24"(6) 10.71"(272) EATON CORPORATION www.eaton.com...
  • Page 18: Specifications

    HMi VU Series Instruction Leaflet Specifications MODEL HMIVU06CUNBE HMIVU07CUNBE HMIVU08CUNBE HMIVU10WCUNBE 10.1” Widescreen 5.6” TFT LCD 7” TFT LCD 8” TFT LCD TFT LCD Display Type (65536 colors) Resolution 320 x 234 pixels 800 x 600 pixels 1024 x 600 pixels...
  • Page 19 In order to ensure the normal operation, it is recommended to use a power supply which the capacity is 1.5 ~2 times the value of the power consumption. For further details, please visit the Eaton website www.eaton.com/electrical. EATON CORPORATION www.eaton.com...