It is imperative that you have your water tested for at the least the parameters listed below. I f the water exceeds the listed parameters CALMAG YORKSHIRE LIMITED strongly recommends that appropriate pretreatment ...
your local environmental health officer. It is always recommended to install pre-‐filtration of at least 5 microns prior to a CALMAG YORKSHIRE LIMITED UV disinfection system. CALMAG YORKSHIRE LIMITED provides pre-‐filters housings a nd c artridges a s s tandard o n t he C ALULTRA 1 2 a nd C ALULTRA 2 2 u nits a nd d o r ecommend p re-‐filters o n ...
System S izing All CALMAG YORKSHIRE LIMITED UV systems are rated for a specific flow rate under specific water quality parameters. The equipment has been designed to ensure that the appropriate dose will be delivered provided all ...
P oint o f U se ( POU) t he s ystem s hould b e t he f inal s tep b efore t he d rinking t ap. Step 2: CALMAG YORKSHIRE LIMITED strongly recommends that the 5 micron filter included be installed before ...
Page 8
Installation example unit connect ASSEMBLED. ring installation unit unit ring unit unit P a g e...
Page 9
Step 11: (Applies only if you have a UV sensor). The UV sensor for the system is packaged in a separate plastic bag. Carefully remove the sensor from its packaging and insert the sensor into the UV sensor port (remove the protective ...
Step 2: Remove the cartridge from the filter housing and fill with 1-‐2 cups of household bleach (most household bleaches a re 5 .25% c hlorine). R eplace f ilter h ousing a nd s lowly t urn o n t he w ater s upply. Step 3: Go to each location in the home or facility (including outdoor taps) and run some water until chlorine can ...
Operation The CALMAG YORKSHIRE LIMITED system comes with a feature laden controller that incorporates both the lamp driver (ballast) and control features in one water-‐tight case. CAUTION: Prior to performing any maintenance on ...
Page 13
a t t he e nd o f 1 2 m onths t o r eplace t he u ltra v iolet b ulb. The Calmag Home Screen will then constantly scroll from right to left indicating that the unit is functioning ...
Page 14
On the Calmag domestic systems (without the UV monitor), the default screen shows the CALMAG YORKSHIRE LIMITED Home Screen. At any point during the operation the user is able to scroll through the CALMAG ...
Page 15
Once the UV output drops below 56%, the numbers and warning sign switch to red and a 15 second intermittent audible c hirp i s g iven o ff b y t he b allast. W hen t he o utput d rops b elow 5 1%, t he d isplay s witches t o a s olid r ed a nd a ...
Page 16
At any point during this sequence, the audible chirp can be deferred by holding the controller button down for a period o f f ive s econds. T he s creen s hown b elow w ill a ppear f or f ive s econds i ndicating t hat t he a udible d efferal h as been ...
Page 17
UV S ENSOR F AILURE: A ssuming t he s ystem h as a U V S ensor i nstalled, i f a t a ny t ime during the operation of the system, a UV sensor fails, the controller will return both an ...
It is imperative that you complete the warranty registration process. This not only registers your UV disinfection system for the provided CALMAG YORKSHIRE LTD warranty, but also allows Calmag Yorkshire Ltd to provide you with any important product updates or technical bulletins concerning your product. The registration process is a ...
Page 20
CALMAG Y ORKSHIRE L IMITED E QUIPMENT SPECIFICATIONS CalUltra d omestic u ltra v iolet s ystems MODEL CalUltra 1 2 CalUltra 2 2 ...