Hide thumbs Also See for ONS 15310-MA SDH:

Quick Links

Install the Cisco ONS 15310-MA SDH
This chapter provides procedures for installing the Cisco ONS 15310-MA SDH shelf, cards, and
fiber-optic cable. To view a summary of the tools and equipment required for installation, see the
"Required Tools and Equipment" section on page
Before You Begin
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
78-18668-01
NTP-H149 Unpack and Inspect the ONS 15310-MA SDH Shelf Assembly, page
this procedure before continuing with the
page
1-5.
NTP-H150 Install the Shelf Assembly, page
assembly in a rack before continuing with the
on page 1-12
or before completing one of the following optional procedures.
NTP-H169 Install the Cable Management Bracket, page
to install the cable management bracket.
NTP-H166 Remove the Blank Sheet Metal Covers, page
to access the backplane.
NTP-H167 Install the EIAs, page
interface assemblies (EIAs) before continuing with the
procedure on page
1-12.
NTP-H151 Install the Power and Ground, page
with the
"NTP-H152 Install the Fan-Tray Assembly" procedure on page
NTP-H152 Install the Fan-Tray Assembly, page
with the
"NTP-H153 Install the 15310E-CTX-K9 Cards" procedure on page
NTP-H153 Install the 15310E-CTX-K9 Cards, page
common- control/cross-connect cards.
NTP-H154 Install the Ethernet Cards, page
Ethernet card.
NTP-H187 Install STM-N Cards and Connectors, page
to install STM-N cards and connectors.
NTP-H155 Install the Electrical Cards, page
electrical card.
C H A P T E R
1-3.
"NTP-H150 Install the Shelf Assembly" procedure on
1-5—Complete this procedure to install the shelf
"NTP-H151 Install the Power and Ground" procedure
1-6—As needed, complete this procedure
1-9—As needed, complete this procedure
1-10—As needed, complete this procedure to install the electrical
"NTP-H151 Install the Power and Ground"
1-12—Complete this procedure before continuing
1-14—Complete this procedure before continuing
1-16—Complete this procedure to install the
1-19—As needed, complete this procedure to install an
1-20—As needed, complete this procedure
1-23—As needed, complete this procedure to install an
Cisco ONS 15310-MA SDH Procedure Guide, R9.0
1
1-5—Complete
1-14.
1-16.
1-1
Table of Contents
loading

Summary of Contents for Cisco ONS 15310-MA SDH

  • Page 1 C H A P T E R Install the Cisco ONS 15310-MA SDH This chapter provides procedures for installing the Cisco ONS 15310-MA SDH shelf, cards, and fiber-optic cable. To view a summary of the tools and equipment required for installation, see the “Required Tools and Equipment”...
  • Page 2 Statement 1040 Note The ONS 15310-MA SDH is designed to comply with Telcordia GR-1089-CORE Type 2 and Type 4. Acceptable applications include Central Office Environments (COEs), Electronic Equipment Enclosures (EEEs), Controlled Environment Vaults (CEVs), huts, and Customer Premise Environments (CPEs).
  • Page 3 Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring. Required Tools and Equipment You will need the following tools and equipment to install and test the ONS 15310-MA SDH. lncluded Materials These materials are shipped with the ONS 15310-MA SDH. The number in parentheses provides the quantity of the item included in the package.
  • Page 4 Bit error rate (BER) tester, E1 and DS-3/E3 • In this chapter, the terms “ONS 15310-MA SDH” and “shelf assembly” are used interchangeably. In the Note installation context, these terms have the same meaning. Otherwise, shelf assembly refers to the physical steel enclosure that holds cards and connects power, and ONS 15310-MA SDH refers to the entire system, both hardware and software.
  • Page 5 NTP-H149 Unpack and Inspect the ONS 15310-MA SDH Shelf Assembly, page 1-5 Required/As Needed Required Onsite/Remote Onsite Security Level None Note The ONS 15310-MA SDH installations are suitable for Network Telecommunication facilities and locations where NEC are applicable. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 78-18668-01...
  • Page 6 • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006 Complete the necessary rack mount task DLP-H248 Mount a Single ONS 15310-MA SDH in a Rack, Step 1 page 18-49.
  • Page 7 If you are installing the extended bracket, install two 8-32 x 0.31 inch (0.79 cm) screws, torqued to 15 Step 3 to 18 inch-lbs, through the top of the bracket directly into the ESD faceplates adjacent to Slots 1 and 6 on either side of shelf (Figure 1-2). Cisco ONS 15310-MA SDH Procedure Guide, R9.0 78-18668-01...
  • Page 8 Blank Sheet Metal Covers” procedure on page 1-9 to access the backplane. If not, continue with the “NTP-H151 Install the Power and Ground” procedure on page 1-12. Stop. You have completed this procedure. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 78-18668-01...
  • Page 9 Blank sheet metal cover Blank sheet metal cover installed on the B Side installed on the A Side Step 2 Store the panels for later use. Attach the backplane cover(s) whenever EIA(s) are not installed. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 78-18668-01...
  • Page 10 Onsite/Remote Onsite Security Level None Connect only SELV services to the high-density EIAs on the ONS 15310-MA SDH. Caution Determine which high-density EIA is designed for installation on the B Side and which is designed for Step 1 installation on the A Side (Figure 1-4).
  • Page 11 1-5). Alternate between the jack screws until the EIA is full seated onto the chassis and the jack screws are hand tight. The EIA is fully mated when both jack screws are fully threaded into the chassis. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-11 78-18668-01...
  • Page 12 This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045 Warning Read the installation instructions before connecting the system to the power source. Statement 1004 Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-12 78-18668-01...
  • Page 13 Use copper conductors only. Statement 1025 Warning Caution Always use the supplied ESD wristband when working with a powered ONS 15310-MA SDH. Plug the wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf. Step 1 Verify that the proper fuse panel is installed (20-amp fuse per shelf minimum).
  • Page 14 Onsite Security Level None Do not operate an ONS 15310-MA SDH without a fan-tray air filter. A fan-tray air filter is mandatory Caution for compliance with IEC 60950-1 standard. You must place the edge of the air filter flush against the front of the fan-tray assembly compartment Caution when installing the fan tray on top of the filter.
  • Page 15 To verify that the tray has plugged into the backplane, look at the fan tray and listen to determine that Step 7 the fans are running. Figure 1-7 shows the location of the fan-tray assembly. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-15 78-18668-01...
  • Page 16 Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement 1029 Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-16 78-18668-01...
  • Page 17 Statement 1085 Caution Do not install a 15310E-CTX-K9 card in an ONS 15310-MA SDH if the ambient temperature exceeds 149 degrees F (65 degrees C). Always use the supplied ESD wristband when working with a powered ONS 15310-MA SDH. Plug the Caution wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf.
  • Page 18 Required Tools and Equipment The 15310E-CTX-K9 cards are hot-pluggable, which means they can be inserted or removed Note without turning off the power to the ONS 15310-MA SDH. Figure 1-8 Installing a 15310E-CTX-K9 Card Verify the 15310E-CTX-K9 card LED activity: Step 2 The red FAIL LED turns on for 30 to 45 seconds.
  • Page 19 The CRAFT ports of ONS15310-MA SDH are intra-building ports used only for setup and maintenance purposes by trained personnel and are not connected during normal operation. Statement 1085 Do not install an Ethernet card in an ONS 15310-MA SDH if the ambient temperature exceeds 149 Caution degrees F (65 degrees C).
  • Page 20 Verify that the card is inserted correctly and close the ejector on the card. The Ethernet cards are hot-pluggable, which means they can be inserted or removed without Note turning off the power to the ONS 15310-MA SDH. Verify the Ethernet card LED activity: Step 2 Verify that the red FAIL LED is off.
  • Page 21 During the boot process, a Locked-enabled, disabled STM-N port will output a line alarm indication Note signal (AIS-L) to any Unlocked-enabled far-end receivers. See the Cisco ONS 15310-MA SDH Troubleshooting Guide for further information about the AIS-L condition. Install higher-capacity cards first; for example, install an STM-64 card before installing an STM-12 card.
  • Page 22 Chapter 1 Install the Cisco ONS 15310-MA SDH Required Tools and Equipment Refer to the card’s reference section in the “Optical Cards” chapter of the Cisco ONS 15310-MA SDH Reference Manual for more information about slot and bandwidth restrictions. Step 2 Open the card latches/ejectors.
  • Page 23 Caution wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf. Do not install an electrical card in an ONS 15310-MA SDH if the ambient temperature exceeds 149 Caution degrees F (65 degrees C).
  • Page 24 NTP-H156 Install the Filler Cards Purpose This procedure installs the filler cards (blank faceplates) in any unused ONS 15310-MA SDH traffic or 15310E-CTX-K9 card slot. The filler cards are detectable in CTC. Tools/Equipment Filler card(s) for empty traffic card slots (15310-EXP-FILLER) and/or a...
  • Page 25 User data channel (UDC) cable: EIA/TIA-232 port cable, CAT-5 terminated with RJ-45 Management LAN cable, CAT-5 terminated with RJ-45 Prerequisite Procedures NTP-H150 Install the Shelf Assembly, page 1-5 Required/As Needed As needed Onsite/Remote Onsite Security Level None Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-25 78-18668-01...
  • Page 26 Caution Always use the supplied ESD wristband when working with a powered ONS 15310-MA SDH. Plug the wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf.
  • Page 27 Purpose This procedure installs and removes SFPs. SFPs are hot-swappable input/output devices that plug into SFP slots on the ONS 15310-MA SDH faceplate to link the port with the fiber-optic network. SFPs are known as pluggable port modules (PPMs) in CTC. You can preprovision the multirate SFPs using the “DLP-H192 Provision a Multirate Pluggable Port Module”...
  • Page 28 To install fiber-optic cables in the ONS 15310-MA SDH, a fiber cable with the corresponding connector Note type must be connected to the transmit and receive ports on the SFPs. On ONS 15310-MA SDH ports, the transmit and receive fiber for each optical signal are contained within a single SFP port.
  • Page 29 As needed, gently route the fiber cables away from the shelf. You might want to use the optional tie-down Step 4 bar. Continue with the “NTP-H164 Perform the Shelf Installation Acceptance Test” procedure on page 1-30. Step 5 Stop. You have completed this procedure. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-29 78-18668-01...
  • Page 30: Table Of Contents

    ONS 15310-MA SDH Shelf Installation Task Summary Description Completed NTP-H149 Unpack and Inspect the ONS 15310-MA SDH Shelf Assembly, page 1-5 NTP-H150 Install the Shelf Assembly, page 1-5 NTP-H169 Install the Cable Management Bracket, page 1-6 NTP-H167 Install the EIAs, page 1-10...
  • Page 31: Required/As Needed

    16-107 as necessary. Verify that no unexplained conditions appear on the network. If unexplained conditions appear, resolve them before continuing. Refer to the Cisco ONS 15310-MA SDH Troubleshooting Guide. Complete the “DLP-H223 Export CTC Data” task on page 18-20 to export alarm and condition information.
  • Page 32: Step

    If you are not logged into CTC and you need to remove a card, continue with Step 3. When you log into Step 1 CTC, troubleshoot the mismatched equipment (mismatchofEquipment) or Improper Removal (IMPRMVL) alarm using the Cisco ONS 15310-MA SDH Troubleshooting Guide. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-32 78-18668-01...
  • Page 33 17-41. Note 1:1 electrical protection groups are created automatically in the ONS 15310-MA SDH and can only be deleted after the protect card of a 1:1 protection group is deleted. The card has circuits; see the “DLP-H120 Delete Overhead Circuits” task on page 17-26 and the •...
  • Page 34 Caution wristband cable into either of the ESD jacks, on the far left and right faceplates in the shelf. Place the door hinge flush against the inside of the ONS 15310-MA SDH chassis flange on the left Step 1 (Figure 1-9).
  • Page 35 Step 8 Close the front door. Be careful not to crimp any cables that are connected to the installed cards. Caution Stop. You have completed this procedure. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-35 78-18668-01...
  • Page 36: Ntp-H158 Install The Electrical Cables

    Onsite Security Level None Caution Always use the supplied ESD wristband when working with a powered ONS 15310-MA SDH. For detailed instructions on how to wear the ESD wristband, refer to the Cisco ONS Electrostatic Discharge (ESD) and Grounding Guide.
  • Page 37: Step 2

    Using the 1/4-inch nut driver, install the six hexagonal standoffs onto the mounting holes that held the six panhead screws. Align the holes on the rear cover with the hexagonal standoffs (Figure 1-11). Step 3 Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-37 78-18668-01...
  • Page 38: Stop. You Have Completed This Procedure

    The rear cover has oval cut-outs to allow this operation. Stop. You have completed this procedure. Cisco ONS 15310-MA SDH Procedure Guide, R9.0 1-38 78-18668-01...

Table of Contents