Confirm Mounting Rack or Outdoor Enclosure Availability

5.13 Confirm Mounting Rack or Outdoor Enclosure Availability
Reference:
If the BS will be housed inside a building, it is typically mounted in a standard 19- or 23-inch rack. Rack
adapters are needed to mount the equipment in a standard 23-inch rack. If the BS will be housed
outdoors, the Service Provider must select and make ready an outdoor enclosure. The Service Provider
can supply an outdoor enclosure from any one of a multitude of vendors. Please refer to
"BWX 8305 Basestation Outdoor Enclosure Manufacturers"
5.13.1 Accessibility
BS equipment is required to be installed in a restricted access location, in accordance with NEC/CEC
standards. Only authorized personnel should have access to this equipment.
5.14 Confirm Power & Grounding Readiness
The BS can be ordered with one of the following power inputs:
The Service Provider is responsible for providing earth grounding and for meeting all regulatory
standards related to power and grounding.
5.14.1 Power Requirements
Please refer to the Technical Specifications for power requirements. When - 48 VDC or +24 VDC input
power is used, the BS must be connected to a power supply/rectifier that is IEC 60950-1 certified (UL
listed to UL60950-1 in North America) and have a ground SELV output. It must be installed in
accordance with NEC/CEC Articles 800/810/830. A UL listed disconnect device, such as a circuit
breaker or fuse, must be installed between the power supply and the BS chassis connections.
BWX 8305 Basestation Installation and Commissioning Guide
5-4
Appendix F, "BWX 8305 Basestation Outdoor Enclosure Manufacturers"
+ 24 VDC
- 48 VDC
100/240, 47/63 Hz VAC
Chapter 5
for recommended manufacturers.
Pre-installation
Appendix F,
OL-16336-02