Siemens SIMATIC Field PG M6 Operating Instructions Manual

Siemens SIMATIC Field PG M6 Operating Instructions Manual

Programming device
Table of Contents

Quick Links

SIMATIC
Programming device
SIMATIC Field PG M6
Operating Instructions
12/2018
A5E43198909-AA
___________________
Preface
___________________
Overview
___________________
Safety instructions
___________________
Installing and connecting the
device
___________________
Commissioning the device
___________________
Operating the device
___________________
Expanding the device
___________________
Maintaining and repairing the
device
___________________
Technical specifications
___________________
Technical support
___________________
Labels and symbols
___________________
Abbreviations
1
2
3
4
5
6
7
8
9
A
B
C
Table of Contents
loading

Summary of Contents for Siemens SIMATIC Field PG M6

  • Page 1 ___________________ Preface ___________________ Overview ___________________ SIMATIC Safety instructions ___________________ Installing and connecting the device Programming device SIMATIC Field PG M6 ___________________ Commissioning the device ___________________ Operating the device Operating Instructions ___________________ Expanding the device ___________________ Maintaining and repairing the device...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Connecting the device ......................33 4.3.1 Connecting the power supply ....................33 4.3.2 Connect SIMATIC S7 or PROFIBUS ..................35 4.3.3 Connecting the device to systems and networks ..............36 4.3.4 Connecting peripheral devices ....................37 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 4 Restoring operating system and partitions ................70 8.2.3 Installing software and drivers ....................71 Configuring firmware/BIOS ....................72 Backing up data ........................72 Modifying the partitions ......................72 Recycling and disposal ......................72 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 5 Labels and symbols ..........................112 Overview ..........................112 Safety ............................ 112 Operator controls ........................112 Certificates, approvals and markings ..................113 Interfaces ..........................114 Abbreviations ............................115 Abbreviations ........................115 Index ..............................117 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 6: Preface

    Validity of this documentation This documentation is valid for all available versions of the SIMATIC Field PG M6 and describes the factory state as of December 2018. Position in the information scheme These operating instructions are included on the supplied data storage medium.
  • Page 7: Security Information

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 8: Overview

    Information on: Online at: Manager Remote maintenance of SIMATIC IPC Remote Manager • • SIMATIC industrial PCs (IPCs) (http://support.automation via a management PC .siemens.com/WW/view /en/48707158) Using Intel ®Active Management • Technology (Intel® AMT) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 9 SIMATIC IPC Image Partition • • directories, drive partitions. Creator (https://w3.siemens.com/mcms /pc-based-automation/en /industrial-pc/expansion _components_accessories /image-and-partition-creator /Pages/Default.aspx) SIMATIC NET Industrial communication Online at: SIMATIC NET • (http://w3.siemens.com/mcms /automation/en/industrial- communications/Pages /Default.aspx) See also Microsoft® Windows® 10 (https://support.industry.siemens.com/cs/ww/de/view/109749498/en?dl=en) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 10: Product Highlights

    Overview 2.1 Product description 2.1.2 Product highlights The SIMATIC Field PG M6 is a robust and turn-key programming tool for the components of SIMATIC industrial automation. SIMATIC Field PG M6 Greatest possible mobility ensured ● Notebook design (dimensions, weight) optimal for use in confined spaces at the plant as well as when traveling ●...
  • Page 11: Application Areas

    2.1.3 Application areas The compact SIMATIC Field PG M6 is designed for use in the field, for example for: ● configuring, programming as well as simulating automation solutions in the office ● commissioning, maintenance and servicing automation solutions on site at the plant ●...
  • Page 12: Design Of The Device

    Overview 2.2 Design of the device Design of the device 2.2.1 Exterior design View with closed display ① Status indicators ② Device handle ③ Display latch SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 13 ① DisplayPort (DPP) ② 2 x Ethernet ③ USB 3.1; Gen. 2; Type A ④ MPI/DP ⑤ DVI-I ⑥ RS232/TTY (TTY functionality, depending on the HW configuration variant) ⑦ Ventilation air outlet SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 14 Exchangeable drive unit ⑤ Card reader for: SIMATIC Memory Card • ⑥ 2 x USB 3.0 ports, with cover Top port: USB 3.0 Type A Bottom port: USB 3.0 Type A with charging function SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 15 Overview 2.2 Design of the device View from below ① Rating plate ② Cover for memory modules ③ Battery SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 16: Operator Controls

    Switch PG on/off (hold the button down for approximately 1 second; the response depends • on the Windows power option settings) Switch PG off in the event of a fault (hold down for more than 5 seconds) • SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 17: Clickpad

    When you only use the clickpad to move the cursor, the whole area (including the mouse buttons) is available. Pressing the left mouse button selects an object. The response to the right mouse button depends on the user program. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 18 If working in an interference-prone environment cannot be avoided, deactivate the tap function (mouse button emulation) using the clickpad driver. Afterwards use the clickpad keys below the clickpad for operation. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 19: Keyboard

    All the keys of the keyboard are equipped with a repeat function, i.e. the character is repeated for as long as the key is pressed. Keyboard labeling The keyboard comes with international and German labeling. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 20 This function is activated using the Num Lock key. The characters and numbers labeled on the front of the number pad keys can be used by simultaneously pressing Fn and one of these keys. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 21 Hibernation mode (depending on the configuration of the Power Button in the Windows Power Options) Fn + F7 Reduce volume Fn + F8 Increase volume Fn + F9 Reduce brightness of screen Fn + F10 Increase brightness of screen SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 22: Status Displays

    Device is switched off Mass storage GREEN Access to external memory: Drive (SSD), optical drive (DVD) MPI interface GREEN MPI interface active Card reader GREEN Module programming (S5 and S7 modules) active SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 23 The WLAN status indicator is located to the right of the keypad LEDs and indicates whether WLAN is active. Symbol Meaning Status indicator Description WLAN ORANGE WLAN switched on WLAN switched off SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 24: Accessories

    (http://www.automation.siemens.com/mcms/pc-based- automation/en/industrial-pc/expansion_components_accessories) Order accessories from the SIEMENS Industry Mall 1. Navigate to the Internet URL of the Industry Mall (https://mall.industry.siemens.com). 2. Log in with your customer data (login on the top right). 3. Select the user language. 4. Navigate to the programming devices in the product catalog (tree structure on the left): "Automation technology >...
  • Page 25: Safety Instructions

    Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. NOTICE Warranty If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 26 ● Always pull the mains connector and disconnect the battery before you install or remove modules which are sensitive to ESD. ● Handle modules fitted with ESDs by their edges only. ● Do not touch any wiring posts or conductors on modules containing ESDs. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 27: Safety Guidelines For Transport

    (condensation). If you notice any condensation, wait around 12 hours before you switch on the device. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 28: Notes On Protecting Administrator Accounts

    To do this, use secure passwords and a standard user account for normal operation. Other measures, such as the use of security policies, should be applied as needed. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 29: Installing And Connecting The Device

    ● Check the delivery unit for any visible transport damage. ● Check the delivery and your specially ordered accessories against the packaging list to ensure nothing is missing. Please inform your local dealer of any disagreements or transport damages. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 30: Device Identification Data

    The rating plate is located on the underside of the device. Example: COA label The COA label is located on the underside of the device. Example COA label for the Microsoft® Windows® 10 operating system: SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 31 1. Enter the order number, serial number and production status in the table above. 2. Transfer the Microsoft Windows Product Key to the table. This is always required to reinstall the operating system. 3. Enter the Ethernet addresses in the table. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 32: Positioning The Device

    ● Open the display by sliding the lock of the display in the direction of the arrow. ● Flip the display open and adjust it to a convenient viewing angle. The display can be adjusted to any inclination angle between 0 and 150 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 33: Connecting The Device

    When working on the device or if the device is not used for a long period of time, always disconnect it fully from the power supply. Shut down the operating system and if you are using the device in mains operation, pull out the power plug. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 34 ① power supply on the left hand side of the device. 3. Plug the external power supply into a socket with a grounded protective conductor. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 35: Connect Simatic S7 Or Profibus

    *) Electrically isolated within the safety extra-low voltage circuit (SELV) NOTICE Risk of damage to the device You could damage the port on the Field PG if you use the wrong connecting cable. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 36: Connecting The Device To Systems And Networks

    You can link the Field PG to an Industrial Wireless LAN network using the integrated WLAN interface. You can find additional information here: Industrial Wireless Communication (IWLAN) (http://w3.siemens.com/mcms/automation/en/industrial-communications/industrial-wireless- communication/Pages/industrial-wireless-communication.aspx) SIEMENS Industry Online Support For more information, the SIEMENS Industry Online Support (https://support.industry.siemens.com) is also available. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 37: Connecting Peripheral Devices

    You can also connect monitors with other appropriate interfaces to the connections for DisplayPort and DVI-I with appropriate adapters. Connecting devices to the USB socket Connect devices such as drives, mouse, keyboard, printer and USB headsets to the USB sockets. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 38 – CTIA: Standard for Apple® audio devices Note Connection of microphone and headphones with two 3.5mm jacks An adapter is needed to simultaneously connect a microphone and headphones to a 3.5-mm-jack. See also Technical specifications (Page 77) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 39: Commissioning The Device

    ● The power supply is connected or the battery is fully charged. Initial startup: Commissioning the operating system Your device is delivered with preinstalled device drivers and SIEMENS software products. After switching on the device for the first time, you can make the following menu-driven personnel settings: ●...
  • Page 40 5. Follow the rest of the instructions on the screen. Once the user has logged on for the first time and the Windows® user interface has loaded, commissioning of the operating system is complete. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 41: Changing The Display Language, Region And Formats Of The Operating System

    The settings of the registered user are copied to the system account and the standard user account for this purpose. 1. Select: "Start > Settings > Time & language". 2. In the "Region & language" area, for the "Add a language" option define a desired "default" language. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 42: Use Of Simatic Software With License Key

    Note Software installed on the SIMATIC Field PG M6 for which a license key is not included in the scope of delivery cannot be used or will only run in Trial mode. SIMATIC Field PG M6...
  • Page 43: Rechargeable Battery

    Risk of fire - Hazardous to people and the environment The improper disposal of batteries may cause fire. Observe the local regulations for the disposal of recyclable materials. Dispose of batteries properly. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 44 End your work and save your data. There are now only a few minutes battery running time left. Please note that for a complete disconnection from the mains the mains connector must be removed. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 45 A loss of capacity over time is technology-dependent and, as with all manufacturers of comparable devices, it is excluded from the warranty. In the case of a significant drop of efficiency we recommend that you replace the battery. Use only Siemens original spare parts.
  • Page 46: Using Batteries

    3. Open the battery cover in the direc- tion of the arrow and, if necessary, remove the old battery. Insert the new battery. 4. Close the cover and turn the device over again. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 47: Operating Modes

    You can recognize these states by the fact that all device status indicators are switched off after removing the power supply. This way you can ensure the device is not switched on and the battery is not unintentionally discharged during transportation. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 48: Operating The Device

    SSDs with different capacities can be used. Note Please use only drives recommended by Siemens. The order data for the drives can be found in the catalog. The corresponding status indicator for the system lights up when the drive is accessed. See sectionStatus displays (Page 22).
  • Page 49 A data storage medium which is hard to read but still readable is in the drive. ● Display flashes initially and then is continuously lit: The data storage medium inserted is not readable and is defective. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 50: Usb Socket With Charging Function

    If you also want to use the charging function in cordless operating mode while the device is shutdown, activate the the corresponding function in the BIOS Setup dialog Power > USB Charger. Note Disable this function again to maintain the minimum possible discharge rate of the battery pack. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 51: Card Reader

    – SIMATIC Memory Card for S7-400 (long design) – SIMATIC Memory Card for S7-300 (short design) SIMATIC Micro Memory Card ● SIMATIC Micro Memory Card for S7-300/C7/ET200 SMC (SIMATIC MC) ● SIMATIC Memory Card for S7-1x00 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 52: Editing Smcs, Sd Cards And Multimedia Cards

    Inserting or removing a card while it is in use could damage it. The card may not be removed as long the status indicator is lit, see section "Status displays (Page 22)". Observe the ESD guidelines (Page 75). SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 53: Modifying Simatic Micro Memory Cards

    Plugging in or removing the module while the module is being changed could damage the module. Do not remove the SIMATIC Micro Memory Card if the module programming status display is lit. Note the ESD Guidelines (Page 75). SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 54: Editing Simatic Memory Cards

    Note Malfunction The simultaneous use of MPI/DP Online and a SIMATIC Memory Card can cause malfunctions. Simultaneous use is not supported. Terminate the use of the SIMATIC Memory Card before using MPI/DP. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 55: Editing Smart Cards

    Card Reader. The Smart Card Reader is located on the right-hand side of the device. When inserting the card, pay attention to the correct positioning of the card. The chip must face upward. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 56: Wlan And Bluetooth

    The infrastructure network uses access points to connect computers to wired networks with the aid of WLAN. These can be a local network (e.g. company networks) or a global network (e.g. Internet). SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 57: Safety Notices For Wlan And Bluetooth Operation

    Siemens. The user alone is responsible for remedying faults that have been caused by such an unauthorized change, or for the use or the replacement of the device.
  • Page 58: Notes On Simatic Software

    You have the following options for starting the TIA Portal: ● Click the TIA Portal icon on the Windows desktop: ● Click the Start button and select the following path: All Programs > Siemens Automation > TIA Portal V1x SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 59: Intel Active Management Technology

    AMT enables virtually unrestricted access to the AMT PC. Protect access to the AMT PC by means of password. You can find additional information on this under Enabling Intel® AMT / basic configuration (Page 105). SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 60: Trusted Platform Module (Tpm)

    Some countries restrict the use of Trusted Platform Modules. Use of Trusted Platform Modules in these countries is not permitted. • Observe all regulations of the country in which the device will be operated. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 61: Expanding The Device

    Refer to the ESD Guidelines (Page 75) for a description of these measures. Note Please use only Siemens memory modules as these have been qualified and cleared for use in this device. You will find the order data in the catalog.
  • Page 62 2. Remove the screw (Torx T6) that holds the cover. 3. Remove the cover. 4. Carefully push the two clamps to the side. The memory module folds up. 5. Pull the memory module out of the slot. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 63 Display of the current memory configuration The memory expansion is automatically detected. The RAM configuration is indicated in the BIOS Setup, "Main" menu. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 64: Maintaining And Repairing The Device

    SSD), a T8 Torx screwdriver and a transport and storage bag. SSD kits are available with the following order numbers: ● 6ES7791-2BA24-0AA0 (256 GB SSD) ● 6ES7791-2BA22-0AA0 (512 GB SSD) ● 6ES7791-2BA25-0AA0 (2 TB SSD) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 65 With the SATA to USB 3.0 adapter (order no. 6ES7790-1AA01-0AA0), you can easily create an image of your system for backup purposes, or as the basis for system-specific installations. See also Accessories (Page 24) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 66: Replacing The Ssd

    ● All connecting cables have been removed from the device. Removing the SSD unit 1. Open the display. 2. Remove both screws (Torx T8) on the cover of the SSD unit. 3. Open the cover and pull out the SSD unit. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 67 1. Carefully slide the new SSD unit into the slot as far as it will go. 2. Close the cover, and secure it with the two screws. See also ESD Guidelines (Page 75) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 68: Replacing The Backup Battery

    Batteries are subject to wear and tear and should be replaced after five years to make sure that your device works correctly. Note The backup battery should only be replaced by the SIEMENS Repair Service. You can find information on this on the Internet at: SIEMENS Repair Service (https://support.industry.siemens.com/cs/ww/en/sc/2154).
  • Page 69: Installing The Operating System, Software And Drivers

    1. Select "Start > Settings > Update & security > Windows Update > Check for update". Windows® determines the updates that are not installed. 2. Then start the download and installation process. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 70: Restoring Operating System And Partitions

    Restoring operating system and partitions You can restore the factory settings of the target system (i.e. the volume partitions, the operating system with installed device drivers, and the SIEMENS software products). This allows you to restore your device quickly if it has suffered damage.
  • Page 71: Installing Software And Drivers

    2. Start the "START.CMD" script from this DVD. 3. Select "Software" or "Drivers" in the index. 4. Select the device and operating system. 5. Select the desired software component or driver. 6. Click on the "Install" icon. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 72: Configuring Firmware/Bios

    (images). It supports burning DVD media. SIMATIC IPC Image & Partition Creator can be ordered using the Siemens online ordering system (https://mall.industry.siemens.com). For more information about SIMATIC IPC Image & Partition Creator, refer to the corresponding product documentation.
  • Page 73: Technical Specifications

    Technical specifications Certificates and approvals ISO 9001 certificate The Siemens quality assurance system for all product creation processes (development, production and sales) meets ISO 9001 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 74: Directives And Declarations

    Connecting peripherals Noise immunity requirements to EN 61000-6-2 are met if connected peripherals are suitable for industrial applications. Peripheral devices must only be connected using shielded cables. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 75: Esd Guidelines

    The electrostatic discharge current may lead to latent failure of a module, that is, this damage may not be significant immediately, but in operation may cause malfunction. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 76 In this way, the discharged energy can not affect the sensitive devices. Discharge your body before you start taking any measurements on a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 77: Technical Specifications

    IEC 60529 Safety Protection class Safety class II according to IEC 61140 Safety specifications IEC 62368-1/EN 62368-1 • UL 62368-1 Second Edition • CAN/CSA C22.2 No. 62368-1-14 Second Edition • SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 78 -20 °C to + 60 °C at max. 20 °C/h (no condensation) Relative humidity tested to IEC 60068-2-78, IEC 60068-2-30, IEC 60068-2-14 During operation 5% to 85% at 30° C (no condensation) Storage/transport 5% to 95% at 25° C (no condensation) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 79 +35° C. Graphic Graphic controller Intel® HD Graphics 630 Graphic controller memory is assigned in the system memory Resolutions/frequencies/colors According to the setting options of the graphics driver SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 80 Up to 1.73 Gbps Keyboard Variant Standard notebook Key distance 19 mm Key drop 2.5 mm Labeling International / German • AZERTY layout (optional) • Pointing device integrated Clickpad with integrated key function SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 81 - Shielding of the DP12 connection line Physical port RS485, electrically isolated Ethernet 2 x Gigabit Ethernet (RJ45) DC-In DC power supply input, jack plug Headphones, microphone, headset UAJ connection for 3.5mm jack SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 82 • Status indicators on the device ● Charge level ● Device status ● Access to SSD ● MPI/DP ● S5 and S7 modules ● Num Lock ● Caps Lock ● WLAN active SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 83: Interface Description

    Short designation Meaning Input/output VBUS + 5 V (fused) Output Data line Input/output Data line Input/output Ground – Data line Input Data line Input Ground – Data line Output Data line Output SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 84 Input/output Data cable (USB 2.0) Input/output Data cable (USB 2.0) Input/output Not assigned VBUS + 5 V (fused) Output RX1- Data cable (USB 3.0) Input RX1+ Data cable (USB 3.0) Input Ground SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 85 9-pin male connector. For this, you only have to plug the adapter onto the COM1 socket and secure it with the two hexagonal head screws. The V.24 and TTY ports of the COM1 can be used alternatively. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 86 Hotplug detect Input TX0N TDMS data 0- Output TX0P TDMS data 0+ Output Ground – Not used – Not used – Ground – TXCP TDMS clock + Output TXCN TDMS clock - Output SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 87 ML_Lane3- DP data 3- Output CONFIG1 CAD Cable Adapter Detect Input CONFIG2 Ground (pull-down) AUX_CH+ Auxiliary channel+ Bi-directional Ground AUX_CH- Auxiliary channel- Bi-directional Hot Plug Detect Input Ground DP_PWR +3.3V (fused) Output SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 88 – LTG_A Signal line A of MPI module Input/output RTS_PG RTS output signal of the MPI module. The Output control signal is "1" when the PG is sending. Shield- on connector casing SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 89 The pins of a 3.5 mm jack are assigned as follows depending on the audio device: Ring 1 Ring 2 Sleeve Headphone out (stereo) Line out (stereo) Line in (stereo) Microphone in (mono) Headset (OMTP) Headset (CTIA) SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 90: Connecting Cables

    DMA channels) are assigned dynamically by the Windows OS, depending on the hardware configuration, drivers and connected external devices. You can view the current assignment of the system resources, or any conflicts with the operating systems. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 91: Firmware/Bios Description

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 92189178. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 92: Opening The Bios Selection Menu

    Depending on the device version, the default settings can differ from the figures shown. The following message appears briefly on the display at the end of the self-test: Press ESC for boot options 2. Press to open the BIOS selection menu: SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 93 Start Intel® Management Engine BIOS Extension (MEBx) so that the Engine BIOS Exten- hardware can be configured for use of the Intel® Active Management sion Technology (iAMT). Available as of Windows 8 or later SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 94: Structure Of The Bios Setup Menu

    ③ Settings, submenus and Information about your device is displayed in the center device-specific information left-hand area; here you can edit settings which are partly in submenus. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 95 Short help texts on the currently selected setup parame- ters are displayed in the center right-hand area. ⑤ Key assignment The key assignment for navigation in the BIOS Setup is found in the footer. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 96: Exit Menu

    Save the BIOS Setup settings as user-specific profile. • Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 97: Bios Setup Settings

    Enabled On-board Ethernet 1 Enabled Ethernet 1 Address 00:1B:1B:41:42:7B (exam- ple) On-board Ethernet 2 Enabled Ethernet 2 Address 00:1B:1B:0A:85:10 (exam- ple) WLAN Last State Enabled SD card Enabled ExpressCard Enabled Touchpad Enabled SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 98 Software Controlled Select Owner EPOCH input type No change in Owner EPOCHs Intel (VMX) Virtualization Tech- Enabled nology Active Processor Cores Hyper-Threading Enabled Enabled Intel® SpeedStep™ Enabled Intel® Speed Shift Technology Enabled SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 99 Enabled Quiet Boot Enabled Network Stack Disabled PXE Boot capability Disabled Add Boot Options Auto USB Boot Disabled EFI Device First Enabled Timeout Legacy / Boot Device Priority Normal Boot Menu Standard SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 100: Bios Update

    6. Save the BIOS Setup settings with "Save and Exit". Preparing a BIOS update NOTICE Irretrievable loss of data If you are using BitLocker drive encryption, pause it before you perform the BIOS update. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 101 There may be several reboots after a BIOS update. These reboots are initiated by the Management Engine (ME). The reboots are required by the ME in order to prepare for the changes of the BIOS update. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 102: Alarm, Error And System Messages

    Keyboard error Field PG: Internal keyboard defective and no • external keyboard connected Other devices: Keyboard defective or not • connected PLD configuration failed Programming of the PLC on the motherboard has failed. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 103: Boot Mode And Partitions In The Delivery State

    The following table lists the partitioning for data storage media ≥ 200 GB on delivery: Partition Name Size File system First Boot 260 MB FAT32 Second 128 MB None Third System Remainder NTFS, not compressed SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 104: Active Management Technology (Iamt)

    SIMATIC IPC with Intel® AMT from it. The following figure shows remote maintenance of SIMATIC IPCs with Intel® AMT, e.g. for troubleshooting a corrupt operating system or incorrect BIOS settings: SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 105: Overview Of Amt

    1. To open the BIOS selection menu, press the key while the device is booting. 2. Use the arrow keys to select "MEBx" and confirm with the key. 3. Select "MEBx Login". SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 106 6. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network with "Activate Network Access". 7. Confirm the dialogs that appear with "Y". Drivers are automatically installed once with the Windows system start in the subsequent restart. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 107: Reset Intel® Amt To Default Settings With Un-Configure

    4. Confirm with "Y". On a German keyboard, this means pressing the key. The device continues to boot with the factory settings of the management engine. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 108: Determining The Network Address

    To allow a user with administrator privileges to avoid this code query, follow these steps: 1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx. 2. Select "Opt-in Configurable from Remote IT". SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 109: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com/cs/ww/en/) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
  • Page 110: Troubleshooting

    < \ > key not available incorrect keyboard driver is with German keyboard driver: < ß> being used with international keyboard driver: < \> SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 111: Problems With Wlan

    In the "classical view" you can select the "Mouse" menu directly. 3. Select the "Device settings" tab and click the "Settings" tab. 4. Select the "Tap" button and deactivate the "Activate tapping" check box. 5. Click "Apply". SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 112: Labels And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 113: Certificates, Approvals And Markings

    Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 114: Interfaces

    LAN interface, not approved for con- Line Out necting WAN or telephone Serial interface Microphone input USB port Universal Audio Jack USB 2.0 HiSpeed interface Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 115: Abbreviations

    Liquid Crystal Display Liquid crystal display LEDs Light Emitting Diode Light emitting diode MLFB Machine-readable product designation Order number Multi Media Card Memory card of the format 32 mm x 24.5 mm SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 116 VT-D Virtualization Technology for Directed I/O Enables the direct assignment of a device (e.g. network adapter) to a virtual device. WLAN Wireless LAN Wireless local area network SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 117: Index

    ESD directives, 75 ESD guidelines, 26 Ethernet address, 31 Caps Lock key, 20 Ethernet interface, 36, 81 Card reader Ethernet RJ45, 36 Status indicator, 22 Expansion Certificate of Authenticity, 40 Memory, 61 Certificates, 73 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 118 PROFIBUS, 36 PROFIBUS / MPI, 81 Network card, 56 New Zealand, 73 RS232/TTY (COM1), 13, 36 RS485, 81 Num Lock key, 20 USB 3.1; Gen. 2, Numeric pad, 20 USB 3.1; Gen. 2, SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 119 Order number, 64 Repairs, 25 SSD unit, 64 Replacing the Standard user account, 41 SSD unit, 66 Standby mode, 47 RoHS Directive, 74 Starting, 58 RS232 interface, 36, 81 Startup, 102 RS485 interface, 81 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...
  • Page 120 USB socket with charging function, 50 Technical specifications, 81 Using rechargeable batteries, 46 Weight, 77 WinCC flexible Starting, 58 Wireless LAN, 36 Regulations, 73 WLAN General information, 56 Status indicator, 23 Technical specifications, 80 Troubleshooting, 18 SIMATIC Field PG M6 Operating Instructions, 12/2018, A5E43198909-AA...

Table of Contents