Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Table of Contents GP10 Model Number Configurator Dimensions & Weights Drive Ratings Efficiency and Watts Loss Installation Environment and Connection Operating Environment Installation Method Connection Basic Connection Diagrams Connecting the Main Circuit and Ground Terminals Connecting the Control Terminals Terminal Configuration...
GP10 GP10 Model Number Configurator Model Number Configurator GP10 GP10 GP10 Model Number Configurator Model Number Configurator Model Number Configurator Description Description GP10 GP10 E1ST E1ST 3 3 3 3 3 4 4 4 4 4...
GP10 Drive Ratings Efficiency and Watts Loss Rated Output Rated Output Efficiency at 2KHz Efficiency at Watts Loss at Watts Loss at Current (A) Power (KVA) 15KHz (%) 2KHz (W) 15KHz (W) Internal DB (W) HP Rating 230VAC 0.25 0.59 92.0...
Installation Environment and Connection 1. Operating Environment CAUTION Install this product in a location that meets the condi- tions listed in Table below. Ensure that the drive and heat sink surfaces are kept free of foreign matter such as lint, paper dust, small chips of wood or metal, and dust.
Page 10
A drive of 40HP or more can be converted to external Installation of Open Type with NEMA 12 Heatsink Drive cooling simply by moving the upper and lower mounting (40 Hp and above) brackets as shown in Fig. 2-2-3. Remove the M6 bracket screws, move the brackets, then secure the brackets using the M5 case mounting screws.
3. Connection Remove the main cover before connecting the terminal blocks as follows. Basic Connection 1. Always connect power to the L1/R, L2/S, and L3/T main circuit power terminals on the drive. Connecting power to another terminal will damage the drive. Check that the input voltage is within the maximum allowable voltage marked on the nameplate, etc.
Basic Connection Diagram (Sink Logic) 20 Hp and above Up to 15 Hp Note: The control circuit common terminals [11], (CM) and are isolated (*1) Use a drive with rated voltage matching the power supply voltage. (*2) Use as required. (*3) Use this peripheral device when necessary.
Page 13
Basic Connection Diagram to PLC (Sink Logic) 20 Hp and above Up to 15 Hp See page 2-4 for notes Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 14
Basic Connection Diagram (Source Logic, Typically used in Europe) 20 Hp and above Up to 15 Hp Note: The control circuit common terminals [11], (CM) and are isolated (*1) Use a drive with rated voltage matching the power supply voltage. (*2) Use as required.
Page 15
Basic Connection Diagram to PLC (Source logic, Typically used in Europe) 20 Hp and above Up to 15 Hp See page 2-6 for notes Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Connecting the Main Circuit and Ground Terminals Table: Functions of main circuit terminals and ground termnals Symbol Terminal Name Description L1/R,L2/S,L3/T Main circuit power terminals Connects a 3-phase power supply U,V,W Inverter output terminals Connects a 3-phase motor R0,T0 Input terminals for auxiliary control power Connects a backup AC power supply to the control circuit (not supported for drives of 1 Hp or less) P1,P(+)
Page 17
The GP10 drive of 20 Hp or more, does not contain a drive circuit for the braking resistor. To improve braking (4) DC reactor terminals (P1 and P(+)) performance, an external braking unit (option) and an 1.
Page 18 When shipped from the factory, CN UX is con- nected to the U1 side. RO-TO L1/R-L3T Fig. 2-3-5 Connection 20 Hp or more, 100 Hp or more parallel resistors, 200 Hp or more parallel braking units. (7) Ground terminal The grounding connector should be sized in accordance <3D view of part A>...
Connecting the Control Terminals The table below lists the functions of the control circuit terminals. A control circuit terminal should be connected according to its function setting. Terminal Classification Symbol Terminal Name Function Analog input Potentiometer power supply Used for +10V DC power supply for frequency setting POT (resistance of 1 to 5k Ohms) Voltage input 1.
Page 20
Digital input Forward operation / Used for forward operation (when FWD-CM is on) or Stop command deceleration and stop (when FWD-CM is opened) Reverse operation / Used for reverse operation (when REV-CM is on) or Stop command deceleration and stop (when REV-CM is opened) Digital input 1 The coast-to-stop command, external alarm, alarm reset, multi- step frequency selection, and other functions (from an external...
Page 21
Transistor Transistor output 1 A running signal, frequency equivalence signal, overload early warning output signal, and other signals from the drive are output (as transistor output) to arbitrary ports. For details, see "Setting the Terminal Functions E20 to E23" in Section 5.2 Function Explanation. * ...
Page 22
(2) Digital input terminals (FWD, REV, X1 to X9, PLC, (6) Wiring of control circuit (inverter of 40 Hp or more) and CM) 1. Pull out the control circuit wiring along the left panel 1. Digital input terminals (e.g., FWD, REV, X1 to X9) are as shown in Fig.
Terminal Configuration 1. Main circuit terminals 60 To 100 Hp 230 VAC 1/4 to 1 Hp 230 VAC 125 to 200 Hp 460 VAC 1/2 to 1 Hp 460 VAC R0 T0 L1/R L2/S L3/T DB P1 P(+) N(–) U P(+) N(–) L1/R L2/S L3/T DB...
2 9 2 Note: • GP10 Drives rated 100 Hp and above are furnished with a DC link reactor. This reactor must be installed between terminal P1 and P+ prior to commissioning of the Drive. • The weight of the DC Link Reactor is not included with that of the Drive.
Function Selection Function Selection List F: Fundamental Functions Unit Factory Setting Data Change Func. Min. Name Setting Range LCD Display Formst during op 30 HP 40 HP DATA PRTC Data protection 0, 1 Frequency command 1 FREQ CMD 1 0 to 11 Operation method OPR METHOD 0 to 4...
Page 27
E: Terminal Extensions Functions Factory Setting Data Change Func. Name Setting Range Unit Format During op LCD Display Min. 30 HP 40 HP X1 terminal function X1 FUNC 0 to 32 X2 terminal function X2 FUNC X3 terminal function X3 FUNC X4 terminal function X4 FUNC 5-18/21...
Page 28
Factory Setting Data Change Func. Name Setting Range Unit Format during op LCD Display Min. 30 HP 40 HP JOG frequency JOG Hz 0.00 to 120.00 Hz 0.01 5.00 5-29 PATTERN (mode select) PATTERN 0,1,2 operation (Stage 1) STAGE 1 Operation time: 0.00 to 6000 s 0.01 0.00 F1...
Page 29
A: Alternative Motor Parameters Factory Setting Data Change Func. Name LCD Display Setting Range Unit Min. 30 HP 40 HP Format During op Maximum frequency 2 MAX Hz-2 50 to 120 Hz Base frequency 2 BASE Hz-2 25 to 120 Hz Rated voltage 2 RATED V-2 230V class: 230...
Protective Operations List of Protective Functions In the event of an abnormality in the inverter’s operation, the protective function will activate immediately to trip the inverter and display the alarm name on the LED monitor while the motor coasts to a stop. A list of the alarms with their explanations is included in the table below, and troubleshooting charts in Section 7.
Alarm Reset 10ms or more To release the trip status, enter the reset command by pressing the RESET key on the keypad panel or sending the appropriate signal to the RST terminal after removing Reset command the cause of the trip. Since the reset command is an Keypad panel display edge operation, input a command sequence such as Normal display...
Warranty Registration Card located inside back cover. OUT-OF WARRANTY PROCEDURES When the defective part has been identified, contact your local authorized Saftronics drives distributor to order replacement parts. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 47
Outline Dimensions Open Type-Variable Torque/ Constant Torque Surface Mount Through Panel Mount 230V Series-Variable Torque, Constant Torque DIMENSION Inch (mm) Mtg. Weight 2 3 0 V Bolts Lb (kg) 4 0 / 3 0 1 3 . 4 9 . 4 1 2 .
Page 48
Alternative Through Panel Mount (bottom bracket support by Surface Mount Through Panel Mount customer supply. 3 or 4 dia. C 4-dia.1.4 (35) Lifting bolts H2 H1 Holes for Holes for mtg. bolts Holes for mtg. bolts mtg. bolts H3 H1 4-ØC 460V Series Open Type-Variable Torque, Constant Torque DIMENSIONS inches (mm)
Page 49
Outline Dimensions Open Type with NEMA 12 Heatsink Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
EMC Directive to be demonstrated to both an integrator of GP10 drives and to his customer or the installer and the user. GP10 drive is supplied ‘CE-marked’, signifying compliance with EC Directive 89/336/EEC when fitted with speci- fied filter units installed and earthed in accordance with this sheet.
Page 54
Figure 5 Outline Dimensions (RF3880-F11) Figure 5 Outline Dimensions (RF3880-F11) Figure 5 Outline Dimensions (RF3880-F11) Figure 5 Outline Dimensions (RF3880-F11) Figure 5 Outline Dimensions (RF3880-F11) Figure 6 Figure 6 Figure 6 Figure 6 Figure 6 230V all Hp 230V all Hp 230V all Hp 230V all Hp 230V all Hp...
Page 55
GP10 460V 400 Hp and higher Figure 7 Figure 7 Figure 7 GP10 460V 400 Hp and higher GP10 460V 400 Hp and higher GP10 460V 400 Hp and higher Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 57
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...