Removing The Operate Switch; Removing The Reset Switch - Epson GT-9000 Service Manual

Image scanners
Hide thumbs Also See for GT-9000:
Table of Contents
Disassembly and Assembfy

3.2.10 Removing the Operate Switch

1. Remove thedocument cover and the uppercase. (Refer to Section 3.2Q.)
2. Remove thecarriageassembly. (Refer to Section 3Q3.)
3. Remove the bottom plate. (Refer to [email protected].)
4. Disconnect connector CN3 on the B027 PSB/PSE board.
5. Remove the CBB-tite (M3 x 10) screw.
Remove the operate switch.
6.
Figure 3-14. Removing the Operate Switch
3.2.11 Removing the Reaet Switch
1. Remove thedocument cover and the uppercase. (Refer to Section 3.2.2.)
2. Remove thecarriageassernbly. (Refer to Section 3Q3.)
3. Remove the bottom plate. (Refer to Swtion3.2.4.)
4. Disconnect connector CN70n the B027 MAIN board.
5. Remove the CBB-tite (M3 x 10) screw.
6. Remove the reset switch.
Reset
Figure 3-15. Removing the Reset Switch
3-14
Rev. A
Table of Contents
loading

This manual is also suitable for:

Es-1200c